Anolis Ambiane HP111 is a recessed lighting fixture designed for professional installations, offering precise illumination with a wide range of applications. Its compact design allows for easy integration into various environments, making it suitable for both indoor and outdoor use. The device features flexible control options with DMX and DALI compatibility, enabling seamless integration into existing lighting systems. Additionally, its 48V secondary power connection ensures safe and efficient operation.

Anolis Ambiane HP111 is a recessed lighting fixture designed for professional installations, offering precise illumination with a wide range of applications. Its compact design allows for easy integration into various environments, making it suitable for both indoor and outdoor use. The device features flexible control options with DMX and DALI compatibility, enabling seamless integration into existing lighting systems. Additionally, its 48V secondary power connection ensures safe and efficient operation.

INSTALLATION INSTRUCTIONS
AMBIANE HP111 RECESSED
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: inf[email protected] | www.anolislighting.com
VERSION 1.0 / 01_2022 1
The unit must be installed by a qualied electrician in accordance with all national and local
electrical and construction codes and regulations.
STEP 1
CEILING OPENING
Push in and twist the Front frame counter-clockwise to re-
lease it from locks. Take out the Front frame with optics.
Standard mounting hole with diameter of 133mm.
STEP 2
DISASSEMBLING OF FRONT FRAME WITH OPTICS
Locks that are holding a Front frame of luminaire.
1 2
INSTALLATION INSTRUCTIONS
AMBIANE HP111 RECESSED
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: inf[email protected] | www.anolislighting.com
VERSION 1.0 / 01_2022 2
Place control unit above the ceiling through the ceiling ope-
ning.
STEP 3
MOUNTING OF CONTROL UNIT
STEP 4
PRIMARY POWER CONNECTION
Mount the control unit to ceiling via two mounting holes and
suitable fasteners.
Install terminal blocks on DMX or DALI data cables and conne-
ct them to the control unit.
DMX CONNECTION
0V D- D+
Data Ground Data - Data +
Set the DIP switches to positions according to your operation
mode. The xture can be controlled by DMX or DALI (switch
11 in OFF position).
STEP 5
DATA CABLES CONNECTION (DMX OR DALI)
1A 1B
Install terminal block to power cable (from Ambiane Power Rack or Ambiane Power HP) and connect it to Primary power socket of the control unit.
1 2
INSTALLATION INSTRUCTIONS
AMBIANE HP111 RECESSED
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: inf[email protected] | www.anolislighting.com
VERSION 1.0 / 01_2022 3
Install terminal block on Secondary power cable and connect it to Secondary power socket of the control unit.
STEP 6
SECONDARY POWER CABLE CONNECTION 48V
STEP 7
LED UNIT CONNECTION
LED Unit Connection
TERMINAL
BLOCK + A B -
Colour of Wire Red White Blue Black
Strip these lengths of LED unit‘s cable for wiring connection.
1
Install terminal block on LED unit‘s cable and connect it to the
control unit.
Shorten power/data cable of LED unit to required length.
2
3
Connected luminaire before installation.
LED unit connected to control unit prior to mounting.
INSTALLATION INSTRUCTIONS
AMBIANE HP111 RECESSED
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: inf[email protected] | www.anolislighting.com
VERSION 1.0 / 01_2022 4
Secure the luminaire in the ceiling opening with two holders,
adjustable via two screws located inside the luminaire. Use
PH2 screwdriver to screw the holders into extended down-
ward position, until they are holding the luminaire rmly in the
ceiling.
(Clockwise - holder moves down, Counter-clockwise - holder
moves up)
STEP 8
MOUNTING OF LUMINAIRE
Holders in extended downward position holding the xture in
the ceiling opening.
Insert luminaire into prepared ceiling opening.
Make sure all cables are connected before installation.
(Instructions above)
Top view of luminaire with extended holders.
3
1 2
INSTALLATION INSTRUCTIONS
AMBIANE HP111 RECESSED
ROBE lighting s. r. o. | Palackeho 416 | 757 01 Valasske Mezirici | Czech Republic | Tel.: +420 571 751 500 | E-mail: inf[email protected] | www.anolislighting.com
VERSION 1.0 / 01_2022 5
STEP 9
ASSEMBLING FRAME WITH OPTICS
Insert Top frame with optics into luminaire.Position the Top frame according to installation marks. Marks
of the luminaire and Top frame must be on top of each other.
Push Top frame into luminare and twist it clockwise, until it‘s
locked in the position.
STEP 10
INSTALLATION OF ACCESSORIES
RING LOUVER FOR 20° REFLECTOR
Insert the Ring Louver into the Top frame.
TOP Frame
Luminaire
1 2
3
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Anolis Ambiane HP111 User manual

Category
Stroboscopes & disco lights
Type
User manual

Anolis Ambiane HP111 is a recessed lighting fixture designed for professional installations, offering precise illumination with a wide range of applications. Its compact design allows for easy integration into various environments, making it suitable for both indoor and outdoor use. The device features flexible control options with DMX and DALI compatibility, enabling seamless integration into existing lighting systems. Additionally, its 48V secondary power connection ensures safe and efficient operation.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI