Identification:
Technical
Bulletin no:
Date:
Issuer:
Factory:
D02-D04
CGX2006-26 (page 1 of 2), 2
nd
ed.
08 March 2007
R. Sartor (DWS Customer Support)
DW Vallenoncello - Italy
Subject
Water Leakage at the Rear Window of CWS machines
Model
Undercounter LS6EA / WT38 and Hood Type LS14EA / WT65E with
Continuous Water Softener built-in.
Problem
Water leakage from the rear open window (air break).
Reason
Tank filling not properly set or boiler/tank filling not working properly.
Action in
Factory
Since serial number 61700001 we have introduced the firmware release
4.0260004 in main boards 0L0731 (not lead-free) and 0L1238 (lead-free) with
following new features:
• Disabled tank filling by boiler overflow whether SEr = 9 even if btF = 0.
Therefore Undercounter/Hood Type with Continuous Water Softener built-
in are always filled by short rinse cycles (btF = 75 as standard).
• Disabled tank filling by boiler overflow if the water level decreases
because of:
1. level switch malfunctioning
2. over-flow pipe not fitted properly
3. drain cycle / self-cleaning cycle stop manually before the end
4. opening door during drain cycle / self-cleaning cycle
5. drain hose connected as for gravity drainage instead of having outlet
between 750 mm and 1000 mm from the floor (see handbook).
Therefore Undercounter/Hood Type with Continuous Water Softener built-
in are
always filled by short rinse cycles.
• Decreased inlet valve delay from 3 seconds to 2 seconds since reed
sensor at the rear has open circuit (float level switch is in upper position).
This parameter cannot be changed by the user interface.
Firmware release
4.0260004
main board 0L1238
Firmware release
4.0260004