  • Hello! I am an AI chatbot trained to assist you with the Electrolux 727086 (RCDR4M26U) Datasheet. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Identification:
Technical
Bulletin no:
Date:
Issuer:
Factory:
D02-D04
CGX2006-13 (page 1 of 1), 2
nd
ed.
29 June 2007
R. Sartor (DWS Customer Support)
DW Vallenoncello - Italy
Subject
“SEr” Parameter in UC/HT with CWS
Model
Undercounter LS6EA / WT38 and Hood Type LS14EA / WT65E with
Continuous Water Softener built-in.
Problem
Not working water softener after main board replacement (it seems the main
board resets SEr = 1 by itself).
Actions in
Field
Configuration parameters must be set following the sequence in the relevant
programming sheet (available in the service manual).
Therefore the parameter SEr must be set = 9 after having set all remaining
parameters and switched the machine off/on, otherwise the “dFL” sets the
main board as for a machine without water softener.
Example for Undercounter: set CFG parameters as first
ELECTROLUX PROFESSIONAL SPA
MAILING ADDRESS TELEPHONE WEBSITE VAT NO.
VIA SEGALUZZA, 30
33170 PORDENONE - ITALY
++39 0434 380650 www.electrolux.com 00072220932
Switch the machine OFF/ON Then set SEr = 9
Switch to the next parameter (“Adr”) then switch the machine OFF/ON.