kozy heat Slayton 60 Direct Vent Fireplace Operating instructions

Category
Fireplaces
Type
Operating instructions
Please leave these reference guides at the installaon locaon unl the installaon is nished. See owners manual for full installaon and nishing
instrucons before making nal decisions as informaon is subject to change.
Model BTU
Height Front Width Back Width Depth Glass Viewing
Area
Actual Framing Actual Framing Actual Framing Actual Framing
SLA60 55,000 311/16 367/8 66 711/8 66 711/8 1513/16 19 587/16 x 141/4
Specicaons (all measurements are in inches)
Framing Opening
Finish Trim Kit
Finishing Clearances Mantel Clearances
Important!
If you are nishing around
the replace with le or
stone make sure that you
install the Finishing Trim
Kit at the framing stage.
The trim kit allows for
your nishing board and
your le/stone to nish
up against, creang a
shadowbox for the face
to sit inside.
Slayton 60 Direct Vent Fireplace
Dimension SLA60
N 725/8
O 383/8
GAS LINE OPENING: LEFT/RIGHT SIDES ELECTRICAL ACCESS: RIGHT SIDE
Dimension SLA60
A 621/4
B 367/8
C 711/8
D 19
CORNER INSTALLATION
HORIZONTAL TERMINATION
VERTICAL TERMINATION
E F G H I J K L M
19 711/8 19 711/8 1101/8 711/8 321/8 551/16 777/8
G
D
C
B
A
E
F
H
J
I
K
FRAMING STUDS MUST
MAINTAIN 1” CLEARANCE
TO VENTING
L
M
P Q R S T
401/4 141/4 171/4 313/16 621/4
45o
NONCOMBUSTIBLE ZONE
S
T
Q
P
R
EACH SQUARE
REPRESENTS 1”
OF MANTEL
PROJECTION
3/4” NONCOMBUSTIBLE
MATERIAL ONLY
Dimension
12”
9”
33/16”
33/16”
4”
Combusble Material Allowed
NonCombusble Material Only
O
N
Lower cover panel combusble material
allowed, but no screws above the framing
NonCombusble Material Only Combusble Material Allowed
12/19
Horizontal Terminaon Framing
Horizontal Venng Minimum Requirements
Heat Shield Requirements
Consult venng chart in
manual for opons above
minimum requirements
The vercal vent heat shield must be installed for EVERY type
of venng applicaon.
The horizontal vent heat shield must be installed when
incorporang minimum horizontal venng.
Note specic gas type minimums
V = Vercal
H = Horizontal
MAX
Dimension SLA60
U 19
V 537/8
W 613/8
X 537/8
Y 613/8
Minimum LP Gas
800 Series FlexVent Kit Venng
U U
U U
V
W
X Y
Minimum Natural Gas Minimum Natural Gas Minimum LP Gas
Requirement SLA60
(LP) Vercal Min 24 + 90o Elbow
(LP) Horizontal Min 9
(LP) Horizontal Max 24
Requirement SLA60
(NG) Vercal Min 12 + 6 + 90o Elbow
(NG) Horizontal Min 9
(NG) Horizontal
Max
36
H
MAX
H
MIN
V
MIN
H
H
MIN
V
MIN
MIN
V
NATURAL GAS SCREW LOCATION
Vercal Heat Shield
PROPANE SCREW LOCATION
Align the (3) screw holes on the horizontal heat shield tabs
to the corresponding (3) screw holes on the vercal heat
shield necessary for your installaon
6” Propane
aachment
piece
A horizontal
Wall Thimble
allowing a
1” clearance
is required
12/19
  • Page 1 1
  • Page 2 2