Bayport 36

kozy heat Bayport 36 Operating instructions

  • Hello! I am an AI chatbot trained to assist you with the kozy heat Bayport 36 Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Please leave these reference guides at the installaon locaon unl the installaon is nished. See owners manual for full installaon and nishing
instrucons before making nal decisions as informaon is subject to change.
Model BTU
Height Front Width Back Width Depth Glass Viewing
Area
Actual Framing Actual Framing Actual Framing Actual Framing
BAY36
(all versions) 26,500 32 42 353/4 361/4 187/8 361/4 1513/16 157/8 291/4 x 233/4
Specicaons (all measurements are in inches)
Framing Opening
Dimension BAY36
D 161/4
E 361/4
F 261/2
G 361/4
H 507/16
I 361/4
J 117/8
K 355/8
L 2411/16
Finish Trim Kit
Finishing Clearances
Dimension BAY36
M 373/4
N 101/2
Important! If you are nishing around
the replace with le or stone make sure that you
install the Finishing Trim Kit at the framing stage.
The trim kit allows for your nishing board and
your le/stone to nish up against, creang a
shadowbox for the face to sit inside.
Do not use with RSF fronts, all other fronts apply.
A
D
E
F
G
B
C
H
I L
K
J
M
N
Bayport 36 Direct Vent Fireplace
1”
1”
¼”
Top Venng
Rear Venng
Top Venng/Corner
GAS LINE OPENING: RIGHT SIDE ELECTRICAL ACCESS: LEFT SIDE
Dimension BAY36
A 42
B 361/4
C 157/8
Combusble Material Allowed
NonCombusble Material Only
12/19
451/2”
NOTE: The clearances allowed here are ONLY for Safety Screen Fronts
with part numbers that include the number 2 ( Example: #B36PSF2 )
Mantel Clearances
All other screen front installaons must
follow the clearances outlined here
Clearances outlined in this drawing are
for installaons with screen front
#B36RSF2 ONLY
Dimension BAY36
O 32
P 11/2
Q 3/4
R 5
S 7
T 9
O
P
Q
R
S
T
Dimension BAY36
U 32
V 41/2
W 3/4
X 8
Y 10
Z 12
COMBUSTIBLE FLOORING (no vinyl or carpet) COMBUSTIBLE FLOORING (no vinyl or carpet)
U
V
W
X
Y
Z
451/2” 451/2”
10”
8”
6”
1/2”
NONCOMBUSTIBLE
MATERIAL ONLY
10”
8”
6”
1/2”
NONCOMBUSTIBLE
MATERIAL ONLY
12/19
Horizontal Terminaon Framing
Horizontal Venng Minimum Requirements
Dimension BAY36
AA 39
BB 26
CC 51
CC
161/4”
3”
1”
H = Horizontal
V = Vercal
Note specic gas type minimums
800 Series FlexVent Kit
Requirement BAY36L
(NG/LP) Vercal Min 90o Elbow
(NG/LP) Horizontal Min 6
(NG/LP) Horizontal Max 8 .
TOP VENTING
Requirement BAY36G
(NG/LP) Vercal Min 6 + 90o Elbow
(NG/LP) Horizontal Min 6
(NG/LP) Horizontal Max 8 .
TOP VENTING Requirement BAY36L/G
(NG) Horizontal Min 6
(NG) Horizontal Max 48
(LP) Horizontal Min 6
(LP) Horizontal Max 12
REAR VENTING
The vercal vent heat shield must be installed for EVERY type of venng
applicaon.
The horizontal vent heat shield must be installed when incorporang
minimum horizontal venng and is posioned according to the gas type.
VENT STANDOFF TAB
Heat Shield Requirements
PROPANE LOCATION
NATURAL GAS LOCATION
Consult venng chart in the manual for all
opons above minimum requirements
Vercal Heat Shield
LOG MODEL GLASS MODEL
BOTH MODELS
161/4” 161/4”
BB
AA
12/19
/