Savant SKL-1000-00 Reference guide

Category
Access control readers
Type
Reference guide
The Savant® Keypad Link (SKL-1000) Quick Reference Guide provides the information
necessary to install the SKL-1000. Each SKL-1000 connects up to 12 Savant keypads to any
Savant controller with available RS-232 port. If keypads are double ganged, they are considered
2 keypads.
Box Contents
(1) SKL-1000
(1) Installation Kit (075-0127-xx)
(1) 24V DC 1.67-Amps Power Supply (025-0115-xx)
(1) 3-Position Screw-Type Plug-In Connector (028-0432-xx)
(1) Power cord (3 feet) (N. America) (064-0079-xx) or appropriate international power
cord
(4) #6 x 1/4 in Screw (039-0143-xx)
(2) Side Mounting Brackets for Extender Boxes (071-0494-xx)
(1) Quick Reference Guide (this document)
Required Components
Savant controller with an allocated RS-232 connector
Savant Keypads: Up to 12 supported per SKL-1000
Savant Faceplates
Savant Keypad Buttons
Cabling
100 ft/30.48 meters (CBL-4100)
250 ft/76.20 meters (CBL-4250)
500 ft/152.40 meters (CBL-4500)
1000 ft/304.8 meters (CBL-41000)
Specifications
Environmental
Environmental
Temperature
32° to 104° F (0° to 40° C)
Humidity
10% to 90% Relative Humidity (non-condensing)
Dimensions and Weight
Dimensions and Weight
Dimensions (H x W x D)
1.27 in x 3.00 in x 3.13 in (3.22 cm x 7.62 cm x 7.95 cm)
Weight
0.5 lb/0.226 kg
Power
Power
Input
100-240V AC 47/63 Hz 0.93 Amps
Supply Requirement
24V DC 1.67 Amp
Maximum Power Draw
40 watts
Cable
Cable
Keypad/station
16 AWG (recommended) 1000 ft (300 meters), cumulative
Keypad/station
18 AWG 330 ft (100 meters), cumulative
Compliance
Compliance
Safety and Emissions
FCC Part 15 | CE Mark | C-Tick
RoHS
Compliant
1
RS-232 port
Port Type: RJ-45
Connects to Savant SmartLighting Controller: SSL-P002 or
SSL-P018
2
Serial Traffic LED
RED flashing indicates serial traffic.
Solid RED indicates overload.
Off indicates no serial traffic.
3
SB Traffic LED
RED flashing indicates station bus (data) to or from keypads.
Solid RED indicates overload.
Off indicates no data traffic.
4
PWR LED
GREEN indicates power is connected.
Off indicates power has been disconnected.
5
24VDC port
24V DC 100-240V AC 47/63 Hz
Connector
3-pin connector, removable plug in
Connects to Savant keypads/stations
Keypad/station
cable length
16 AWG (recommended) 1000 ft (300 meters), cumulative
Keypad/station
cable length
18 AWG 330 ft (100 meters), cumulative
Wiring the Savant Keypads to the Savant Keypad Link
To connect the keypads to the SKL-1000, the wires from the 3-pin connectors must be spliced
with the 3-wire cable running to the keypad backboxes. The next figure shows the use of 16-
gauge (AWG) wire, but in shorter installations (up to 330 feet) 18-gauge wire can be used. Crimp
connectors or wire nuts can be used to terminate the stranded wire. Crimp connectors are
preferred.
Control Station Backbox Control Station Backbox Control Station Backbox
3 PIN
CONNECTOR
3 PIN
CONNECTOR
LiteTouch Control Station Wire
5 ea. 18 ga. Wires
White Spare Wire 16 ga.
Spare Wire
Blue 16 ga. (D)
Black 16 ga. (–)
Red 16 ga. (
+)
18 ga. Blue Connector
18 ga. Red Connector
Twist pair together for
connection to black
ground connector
NOTE: Voltage readings at this end should typically
read 1 or 2 volts less than at the CCU end.
Use crimp
connectors or
wirenuts.
(Crimp connectors are preferred.)
Keep the control station in its protective plastic bag until all construction work is completed.
Control Station Backbox Control Station Backbox Control Station Backbox
3 PIN
CONNECTOR
3 PIN
CONNECTOR
LiteTouch Control Station Wire
5 ea. 18 ga. Wires
White Spare Wire 16 ga.
Spare Wire
Blue 16 ga. (D)
Black 16 ga. (–)
Red 16 ga. (
+)
18 ga. Blue Connector
18 ga. Red Connector
Twist pair together for
connection to black
ground connector
NOTE: Voltage readings at this end should typically
read 1 or 2 volts less than at the CCU end.
Use crimp
connectors or
wirenuts.
(Crimp connectors are preferred.)
Keep the control station in its protective plastic bag until all construction work is completed.
Savant SmartLighting Station Bus Wire for Keypad Connection
Control Station Backbox Control Station Backbox Control Station Backbox
3 PIN
CONNECTOR
3 PIN
CONNECTOR
LiteTouch Control Station Wire
5 ea. 18 ga. Wires
White Spare Wire 16 ga.
Spare Wire
Blue 16 ga. (D)
Black 16 ga. (–)
Red 16 ga. (
+)
18 ga. Blue Connector
18 ga. Red Connector
Twist pair together for
connection to black
ground connector
NOTE: Voltage readings at this end should typically
read 1 or 2 volts less than at the CCU end.
Use crimp
connectors or
wirenuts.
(Crimp connectors are preferred.)
Keep the control station in its protective plastic bag until all construction work is completed.
Keypad Backbox
Note: Voltage readings at the end closest to the 3-pin connector should typically read no more
than 1 or 2 volts less than at the Savant Keypad Link end.
Keypad backboxes should have a minimum inside dimension of 3 in. high x 1 in. wide x 1½ in
deep. Use a square-cornered backbox to best accommodate these dimensions. Do not use
plastic rings with rounded corners—keypads, especially multiple-gang keypads, will not fit.
Single-gang, metal cut-in boxes, plaster, or tile rings are not acceptable.
In new construction installations, for example, a single gang backbox, model P-241 (supplied by
Allied Moulded Products) would accommodate a Savant keypad. An example of a double gang
backbox is model P-442 (supplied by Allied Moulded Products).
Whether installing backboxes in new construction or “old work” installations, the installer should
test fit the keypad to the backbox before installing the backbox in a wall.
Note: Keypads may be wired to a homerun device, not to exceed 1000 feet with 16 AWG or 330
feet with 18 AWG.
SKL-1000 Mounting Bracket Installation
Additional Documentation
Additional Documentation for the SSL-P002 is available at: SavantSystems.com
Products >
Savant Lighting Control
Savant Keypad Link
(SKL-1000)
Quick Reference Guide
009-0556-01
SKL-1000-00
101712
Copyright © 2012 Savant Systems, LLC. SAVANT and RacePoint Blueprint are trademarks of Savant Systems, LLC.
All brand names, product names and trademarks are the property of their respective owners.
Savant Systems, LLC reserves the right to change product specifications without notice.
  • Page 1 1

Savant SKL-1000-00 Reference guide

Category
Access control readers
Type
Reference guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI