In accordance with our policy of continuous product development and improvement,
this information is subject to change at any time without notice.
EI219395 Issued (TFB/KAK) 7 May, 2001
Manitowoc Beverage Equipment
2100 Future Drive Sellersburg, IN 47172-1868
Tel: 812.246.7000, 800.367.4233 Fax: 812.246.9922
www.manitowocbeverage.com
Foodservice Group
Multiplex Beverage Equipment Installation Instructions for
Accumulator Tank Replacement for
Model WBK8 and WBK8X Water Booster Pump
P.N. 00212136 and P.N. 00212146
Introduction
The following instructions brake down step by step instruc-
tions for replacing the Accumulator Tank for Multiplex
Model WBK8 and WBK8X Water Booster Pump. Be sure to
read through these instructions completely before replacing
the tank.
Important: Be sure to read “Caution: To Avoid Serious Injury”
before proceeding with installation.
Removal of the old accumulator tank
1. Disconnect the Water Booster Pump from the power
source. Unplug the unit or turn the circuit breaker “off”.
2. Turn the water supply to the Water Booster Pump “off”.
Relieve the pressure from the Water Booster Pump by
opening the Pressure Relief Valve on the manifold.
Disconnect the tank from the manifold
at the union.
Remove the union from the old tank.
Note: DO NOT discard the union half.
Pressure Relief Valve
Accumulator Tank
Remove old tank.
Drill out rivet that hold the straps
to the risers and remove straps.
Note: DO NOT discard straps.
Accumulator
Tank Straps
3. Separate the Accumulator Tank from the manifold at the
union located at the front of the tank. Remove the two
(2) bolts and nuts form the hold down straps and remove
the tank.
4. Remove the adaptor along with the union nut from the
tank.
Note: This is required for the New Replacement Tank.
5. Drill the four (4) rivets holding the straps to the risers out
in order to remove the straps.
Note: The straps will be used to mount the new replacement
tank.
Figure 1