  • Hello! I am an AI chatbot trained to assist you with the Fujitsu PRIMERGY RX200 S7 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Upgrade and Maintenance Manual - English
PRIMERGY RX200 S7
Server
Upgrade and Maintenance Manual
Edition October 2013
Comments…Suggestions…Corrections…
The User Documentation Department would like to
know your opinion of this manual. Your feedback helps
us optimize our documentation to suit your individual
needs.
Feel free to send us your comments by e-mail to
Certified documentation
according to DIN EN ISO 9001:2008
To ensure a consistently high quality standard and
user-friendliness, this documentation was created to
meet the regulations of a quality management system
which complies with the requirements of the standard
DIN EN ISO 9001:2008.
cognitas. Gesellschaft für Technik-Dokumentation mbH
www.cognitas.de
Copyright and Trademarks
Copyright © 2012 Fujitsu Technology Solutions GmbH.
All rights reserved.
Delivery subject to availability; right of technical modifications reserved.
All hardware and software names used are trademarks of their respective manufacturers.
– The contents of this manual may be revised without prior notice.
– Fujitsu assumes no liability for damages to third party copyrights or other rights arising from
the use of any information in this manual.
– No part of this manual may be reproduced in any form without the prior written permission
of Fujitsu.
Microsoft, Windows, Windows Server, and Hyper V are trademarks or registered trademarks of
Microsoft Corporation in the USA and other countries.
Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries
in the USA and other countries.
RX200 S7
Upgrade and Maintenance Manual
Before reading this manual
For your safety
This manual contains important information for safely and correctly using this
product.
Carefully read the manual before using this product. Pay particular attention to
the accompanying manual "Safety Notes and Regulations" and ensure these
safety notes are understood before using the product. Keep this manual and the
manual "Safety Notes and Regulations" in a safe place for easy reference while
using this product.
Radio interference
This product is a "Class A" ITE (Information Technology Equipment). In a
domestic environment this product may cause radio interference, in which case
the user may be required to take appropriate measures. VCCI-A
Aluminum electrolytic capacitors
The aluminum electrolytic capacitors used in the product's printed circuit board
assemblies and in the mouse and keyboard are limited-life components. Use of
these components beyond their operating life may result in electrolyte leakage
or depletion, potentially causing emission of foul odor or smoke.
As a guideline, in a normal office environment (25°C) operating life is not
expected to be reached within the maintenance support period (5 years).
However, operating life may be reached more quickly if, for example, the
product is used in a hot environment. The customer shall bear the cost of
replacing replaceable components which have exceeded their operating life.
Note that these are only guidelines, and do not constitute a guarantee of
trouble-free operation during the maintenance support period.
High safety use
This product has been designed and manufactured to be used in commercial
and/or industrial areas as a server.
When used as visual display workplace, it must not be placed in the direct field
of view to avoid incommoding reflections (applies only to TX server systems).
The device has not been designed or manufactured for uses which demand an
extremely high level of safety and carry a direct and serious risk of life or body
if such safety cannot be assured.
Upgrade and Maintenance Manual
RX200 S7
These uses include control of nuclear reactions in nuclear power plants,
automatic airplane flight control, air traffic control, traffic control in mass
transport systems, medical devices for life support, and missile guidance
control in weapons systems (hereafter, "high safety use"). Customers should
not use this product for high safety use unless measures are in place for
ensuring the level of safety demanded of such use. Please consult the sales
staff of Fujitsu if intending to use this product for high safety use.
Measures against momentary voltage drop
This product may be affected by a momentary voltage drop in the power supply
caused by lightning. To prevent a momentary voltage drop, use of an AC
uninterruptible power supply is recommended.
(This notice follows the guidelines of Voltage Dip Immunity of Personal
Computer issued by JEITA, the Japan Electronics and Information Technology
Industries Association.)
Technology controlled by the Foreign Exchange and Foreign Trade
Control Law of Japan
Documents produced by Fujitsu may contain technology controlled by the
Foreign Exchange and Foreign Trade Control Law of Japan. Documents which
contain such technology should not be exported from Japan or transferred to
non-residents of Japan without first obtaining authorization in accordance with
the above law.
Harmonic Current Standards
This product conforms to harmonic current standard JIS C 61000-3-2.
Only for the Japanese market:
About SATA hard disk drives
The SATA version of this server supports hard disk drives with SATA / BC-SATA
storage interfaces. Please note that the usage and operation conditions differ
depending on the type of hard disk drive used.
Please refer to the following internet address for further information on the
usage and operation conditions of each available type of hard disk drive:
http://jp.fujitsu.com/platform/server/primergy/harddisk/
RX200 S7
Upgrade and Maintenance Manual
Only for the Japanese market:
IAlthough described in this manual, some sections do not apply to the
Japanese market. These options and routines include:
– CSS (Customer Self Service)
Upgrade and Maintenance Manual
RX200 S7
RX200 S7
Upgrade and Maintenance Manual
Version history
Issue number Reason for update
1.0 / March 2012 Initial release
2.0 / June 2012 Notes for new hardware added
3.0 / December 2012 Added fan test procedure, changed photos of SFP+
transceiver modules
4.0 / October 2013 Deleted ENERGY STAR, updated fan test procedure
Upgrade and Maintenance Manual
RX200 S7
V
ersion history
RX200 S7
Upgrade and Maintenance Manual
Contents
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
1.1 Where to find which information? . . . . . . . . . . . . . . . 26
1.2 Notational conventions . . . . . . . . . . . . . . . . . . . . 27
2 Before you start . . . . . . . . . . . . . . . . . . . . . . . . 29
2.1 Classification of procedures . . . . . . . . . . . . . . . . . 31
2.1.1 Customer Replaceable Units (CRU) . . . . . . . . . . . . . . . 31
2.1.2 Upgrade and Repair Units (URU) . . . . . . . . . . . . . . . . 32
2.1.3 Field Replaceable Units (FRU) . . . . . . . . . . . . . . . . . 33
2.2 Average task duration . . . . . . . . . . . . . . . . . . . . . 34
2.3 Tools you need at hand . . . . . . . . . . . . . . . . . . . . 35
2.4 Documents you need at hand . . . . . . . . . . . . . . . . . 36
3 Important information . . . . . . . . . . . . . . . . . . . . . 39
3.1 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . 39
3.2 CE conformity . . . . . . . . . . . . . . . . . . . . . . . . . 47
3.3 FCC Class A Compliance Statement . . . . . . . . . . . . . 47
3.4 Environmental protection . . . . . . . . . . . . . . . . . . . 48
4 Basic hardware procedures . . . . . . . . . . . . . . . . . . 51
4.1 Using diagnostics information . . . . . . . . . . . . . . . . 51
4.1.1 Locating the defective server . . . . . . . . . . . . . . . . . . 51
4.1.2 Determining the error class . . . . . . . . . . . . . . . . . . . 52
4.1.2.1 Global Error indicator . . . . . . . . . . . . . . . . . . . . 52
4.1.2.2 Customer Self Service (CSS) indicator . . . . . . . . . . . 53
4.1.3 Locating the defective component . . . . . . . . . . . . . . . . 54
4.1.3.1 Local diagnostic indicators on the system board . . . . . . . 54
4.2 Opening the rack door . . . . . . . . . . . . . . . . . . . . . 55
Upgrade and Maintenance Manual
RX200 S7
Contents
4.3 Shutting down the server . . . . . . . . . . . . . . . . . . . . 55
4.4 Extending/removing the server from the rack . . . . . . . . . 56
4.4.1 Disconnecting the power cord . . . . . . . . . . . . . . . . . . 56
4.4.2 Extending the server out of the rack . . . . . . . . . . . . . . . 57
4.4.3 Removing the server from the telescopic rails . . . . . . . . . . 58
4.5 Opening the server . . . . . . . . . . . . . . . . . . . . . . . 59
4.5.1 Removing the fan cover . . . . . . . . . . . . . . . . . . . . . . 59
4.5.2 Removing the housing cover . . . . . . . . . . . . . . . . . . . 60
4.6 Removing riser modules . . . . . . . . . . . . . . . . . . . . 61
4.6.1 Removing the riser module 1 . . . . . . . . . . . . . . . . . . . 61
4.6.2 Removing the riser module 2 . . . . . . . . . . . . . . . . . . . 61
4.6.3 Removing the riser module 3 . . . . . . . . . . . . . . . . . . . 62
4.7 Removing the air duct . . . . . . . . . . . . . . . . . . . . . . 63
4.8 Installing the air duct . . . . . . . . . . . . . . . . . . . . . . 63
4.9 Installing riser modules . . . . . . . . . . . . . . . . . . . . . 64
4.9.1 Installing the riser module 1 . . . . . . . . . . . . . . . . . . . . 64
4.9.2 Installing the riser module 2 . . . . . . . . . . . . . . . . . . . . 65
4.9.3 Installing the riser module 3 . . . . . . . . . . . . . . . . . . . . 66
4.10 Closing the server . . . . . . . . . . . . . . . . . . . . . . . . 67
4.10.1 Installing the housing cover . . . . . . . . . . . . . . . . . . . . 67
4.10.2 Installing the fan cover . . . . . . . . . . . . . . . . . . . . . . 68
4.11 Installing the server in the rack . . . . . . . . . . . . . . . . . 69
4.11.1 Inserting the server into the telescopic rails . . . . . . . . . . . 69
4.11.2 Sliding the server into the rack . . . . . . . . . . . . . . . . . . 71
4.11.3 Connecting the power cord . . . . . . . . . . . . . . . . . . . . 72
4.12 Switching on the server . . . . . . . . . . . . . . . . . . . . . 73
4.13 Concluding software tasks . . . . . . . . . . . . . . . . . . . 73
4.14 Closing the rack door . . . . . . . . . . . . . . . . . . . . . . 74
5 Basic software procedures . . . . . . . . . . . . . . . . . . . 75
5.1 Starting the maintenance task . . . . . . . . . . . . . . . . . 75
5.1.1 Disabling BitLocker functionality . . . . . . . . . . . . . . . . . 75
5.1.2 Disabling SVOM boot watchdog functionality . . . . . . . . . . . 76
5.1.2.1 Viewing boot watchdog settings . . . . . . . . . . . . . . . . 76
5.1.2.2 Configuring boot watchdog settings . . . . . . . . . . . . . . 76
RX200 S7
Upgrade and Maintenance Manual
Contents
5.1.3 Removing backup and optical disk media . . . . . . . . . . . . 77
5.1.4 Verifying and configuring the backup software solution . . . . . 78
5.1.5 Note on server maintenance in a Multipath I/O environment . . 78
5.1.6 Switching on the ID indicator . . . . . . . . . . . . . . . . . . 80
5.2 Completing the maintenance task . . . . . . . . . . . . . . . 81
5.2.1 Updating the system board BIOS and iRMC . . . . . . . . . . 81
5.2.2 Verifying system information backup / restore . . . . . . . . . . 83
5.2.3 Updating RAID controller firmware . . . . . . . . . . . . . . . 84
5.2.4 Enabling Option ROM scan . . . . . . . . . . . . . . . . . . . 85
5.2.5 Verifying and configuring the backup software solution . . . . . 86
5.2.6 Resetting the boot retry counter . . . . . . . . . . . . . . . . . 86
5.2.6.1 Viewing the boot retry counter . . . . . . . . . . . . . . . . 87
5.2.6.2 Resetting the boot retry counter . . . . . . . . . . . . . . . 87
5.2.7 Enabling SVOM boot watchdog functionality . . . . . . . . . . 88
5.2.8 Enabling replaced components in the system BIOS . . . . . . . 89
5.2.9 Verifying the memory mode . . . . . . . . . . . . . . . . . . . 90
5.2.10 Verifying the system time settings . . . . . . . . . . . . . . . . 90
5.2.11 Viewing and clearing the System Event Log (SEL) . . . . . . . 91
5.2.11.1 Viewing the SEL . . . . . . . . . . . . . . . . . . . . . . . 91
5.2.11.2 Clearing the SEL . . . . . . . . . . . . . . . . . . . . . . . 92
5.2.12 Updating the NIC configuration file in a Linux environment . . . 92
5.2.13 Enabling BitLocker functionality . . . . . . . . . . . . . . . . . 94
5.2.14 Performing a RAID array rebuild . . . . . . . . . . . . . . . . . 95
5.2.15 Looking up changed MAC / WWN addresses . . . . . . . . . . 95
5.2.15.1 Looking up MAC addresses . . . . . . . . . . . . . . . . . 95
5.2.15.2 Looking up WWN addresses . . . . . . . . . . . . . . . . . 96
5.2.16 Using the Chassis ID Prom Tool . . . . . . . . . . . . . . . . . 97
5.2.17 Configuring LAN teaming . . . . . . . . . . . . . . . . . . . . 97
5.2.17.1 After replacing / upgrading LAN controllers . . . . . . . . . 98
5.2.17.2 After replacing the system board . . . . . . . . . . . . . . . 98
5.2.18 Switching off the ID indicator . . . . . . . . . . . . . . . . . . 98
5.2.19 Performing a fan test after replacing a defective fan . . . . . . 99
6 Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . 101
6.1 Basic information . . . . . . . . . . . . . . . . . . . . . . . 101
6.1.1 General equipping rules . . . . . . . . . . . . . . . . . . . . . 101
6.2 Installing a power supply module . . . . . . . . . . . . . . . 102
6.2.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . . 102
6.2.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 102
Upgrade and Maintenance Manual
RX200 S7
Contents
6.2.3 Removing the dummy cover . . . . . . . . . . . . . . . . . . 102
6.2.4 Installing the power supply module . . . . . . . . . . . . . . . 103
6.2.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 105
6.3 Removing a power supply module . . . . . . . . . . . . . . 105
6.3.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . 107
6.3.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 107
6.3.3 Removing the power supply module . . . . . . . . . . . . . . 107
6.3.4 Installing the dummy cover . . . . . . . . . . . . . . . . . . . 108
6.3.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 108
6.4 Replacing a power supply module . . . . . . . . . . . . . . 109
6.4.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . 109
6.4.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 110
6.4.3 Removing the defective power supply module . . . . . . . . . 110
6.4.4 Installing the new power supply module . . . . . . . . . . . . 110
6.4.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 110
6.5 Replacing the power distribution board . . . . . . . . . . . 111
6.5.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . 111
6.5.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 111
6.5.3 Removing the defective power distribution board . . . . . . . . 112
6.5.4 Installing the new power distribution board . . . . . . . . . . . 113
6.5.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 115
7 Hard disk drives / solid state drives . . . . . . . . . . . . . 117
7.1 Basic information . . . . . . . . . . . . . . . . . . . . . . . 118
7.1.1 General equipping rules . . . . . . . . . . . . . . . . . . . . 118
7.1.2 Configuration with up to four HDD/SSD modules . . . . . . . . 119
7.1.3 Configuration with up to eight HDD/SSD modules . . . . . . . 119
7.2 Installing a 2.5-inch HDD/SSD module . . . . . . . . . . . . 120
7.2.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . 120
7.2.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 121
7.2.3 Removing the 2.5-inch dummy module . . . . . . . . . . . . . 121
7.2.4 Installing the 2.5-inch HDD/SSD module . . . . . . . . . . . . 122
7.2.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 123
7.3 Removing a 2.5-inch HDD/SSD module . . . . . . . . . . . 123
7.3.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . 123
7.3.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 123
7.3.3 Removing the 2.5-inch HDD/SSD module . . . . . . . . . . . 124
7.3.4 Installing the 2.5-inch dummy module . . . . . . . . . . . . . 125
RX200 S7
Upgrade and Maintenance Manual
Contents
7.3.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 125
7.4 Replacing a 2.5-inch HDD/SSD module . . . . . . . . . . . . 126
7.4.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . . 126
7.4.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 127
7.4.3 Removing the defective 2.5-inch HDD/SSD module . . . . . . 127
7.4.4 Installing the new 2.5-inch HDD/SSD module . . . . . . . . . . 127
7.4.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 127
7.5 Replacing the 4xHDD backplane . . . . . . . . . . . . . . . 128
7.5.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . . 129
7.5.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 129
7.5.3 Removing the defective 4xHDD backplane . . . . . . . . . . . 129
7.5.4 Installing the new 4xHDD backplane . . . . . . . . . . . . . . 131
7.5.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 132
7.6 Replacing the 8xHDD backplane . . . . . . . . . . . . . . . 133
7.6.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . . 133
7.6.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 133
7.6.3 Removing the defective 8xHDD backplane . . . . . . . . . . . 133
7.6.4 Installing the new 8xHDD backplane . . . . . . . . . . . . . . 136
7.6.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 138
7.7 Converting to configuration up to eight HDD/SSD modules 139
7.7.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . . 139
7.7.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 139
7.7.3 Removing the 4xHDD backplane . . . . . . . . . . . . . . . . 139
7.7.4 Removing the ODD cable and ODD cage . . . . . . . . . . . . 140
7.7.5 Installing the 2xHDD cage . . . . . . . . . . . . . . . . . . . . 142
7.7.6 Installing the 8xHDD backplane . . . . . . . . . . . . . . . . . 142
7.7.7 Installing the HDD/SSD modules . . . . . . . . . . . . . . . . 143
7.7.8 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 143
8 Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
8.1 Basic information . . . . . . . . . . . . . . . . . . . . . . . 146
8.2 Replacing a fan module . . . . . . . . . . . . . . . . . . . . 147
8.2.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . . 147
8.2.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 147
8.2.3 Removing the defective fan module . . . . . . . . . . . . . . . 148
8.2.4 Installing the new fan module . . . . . . . . . . . . . . . . . . 148
8.2.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 149
Upgrade and Maintenance Manual
RX200 S7
Contents
9 Expansion cards and backup units . . . . . . . . . . . . . 151
9.1 Basic information . . . . . . . . . . . . . . . . . . . . . . . 152
9.1.1 Equipping the PCIe slots . . . . . . . . . . . . . . . . . . . . 153
9.2 Additional tasks . . . . . . . . . . . . . . . . . . . . . . . . 157
9.2.1 Installing expansion card slot brackets . . . . . . . . . . . . . 157
9.2.1.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 157
9.2.1.2 Installing an expansion card slot bracket . . . . . . . . . . 157
9.2.2 Installing SFP+ transceiver modules . . . . . . . . . . . . . . 164
9.2.2.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 164
9.2.2.2 Installing the first SFP+ transceiver module . . . . . . . . . 164
9.2.2.3 Installing the second SFP+ transceiver module . . . . . . . 167
9.2.3 Removing expansion card slot brackets . . . . . . . . . . . . 167
9.2.3.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 167
9.2.3.2 Removing an expansion card slot bracket . . . . . . . . . 167
9.2.4 Replacing SFP+ transceiver modules . . . . . . . . . . . . . 168
9.2.4.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 168
9.2.4.2 Removing the SFP+ transceiver module . . . . . . . . . . 168
9.2.4.3 Installing the SFP+ transceiver module . . . . . . . . . . . 169
9.3 Expansion cards and riser cards . . . . . . . . . . . . . . . 170
9.3.1 Installing an expansion card in riser module 1 . . . . . . . . . 170
9.3.1.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 170
9.3.1.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 171
9.3.1.3 Removing the slot cover - slot 1 . . . . . . . . . . . . . . . 171
9.3.1.4 Installing the expansion card - slot 1 . . . . . . . . . . . . 172
9.3.1.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 172
9.3.2 Installing an expansion card in riser module 2 . . . . . . . . . 173
9.3.2.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 173
9.3.2.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 173
9.3.2.3 Removing the slot cover - slot 2 and slot 3 . . . . . . . . . 174
9.3.2.4 Installing the expansion card - slot 2 and slot 3 . . . . . . . 175
9.3.2.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 177
9.3.3 Installing an expansion card in riser module 3 . . . . . . . . . 177
9.3.3.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 177
9.3.3.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 178
9.3.3.3 Installing the expansion card - slot 4 . . . . . . . . . . . . 178
9.3.3.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 179
9.3.4 Removing an expansion card in riser module 1 . . . . . . . . 180
9.3.4.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 180
9.3.4.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 180
9.3.4.3 Removing the expansion card - slot 1 . . . . . . . . . . . . 181
RX200 S7
Upgrade and Maintenance Manual
Contents
9.3.4.4 Installing the slot cover - slot 1 . . . . . . . . . . . . . . . . 182
9.3.4.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 182
9.3.5 Removing an expansion card in riser module 2 . . . . . . . . . 183
9.3.5.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 183
9.3.5.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 183
9.3.5.3 Removing the expansion card- slot 2 and slot 3 . . . . . . . 184
9.3.5.4 Installing the slot cover - slot 2 and slot 3 . . . . . . . . . . 185
9.3.5.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 185
9.3.6 Removing an expansion card in riser module 3 . . . . . . . . . 186
9.3.6.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 186
9.3.6.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 186
9.3.6.3 Removing the expansion card - slot 4 . . . . . . . . . . . . 187
9.3.6.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 187
9.3.7 Replacing an expansion card in riser module 1 . . . . . . . . . 188
9.3.7.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 188
9.3.7.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 188
9.3.7.3 Removing the defective expansion card . . . . . . . . . . . 189
9.3.7.4 Installing the new expansion card . . . . . . . . . . . . . . 189
9.3.7.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 189
9.3.8 Replacing an expansion card in riser module 2 . . . . . . . . . 190
9.3.8.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 190
9.3.8.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 191
9.3.8.3 Removing the defective expansion card . . . . . . . . . . . 191
9.3.8.4 Installing the new expansion card . . . . . . . . . . . . . . 191
9.3.8.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 191
9.3.9 Replacing an expansion card in riser module 3 . . . . . . . . . 192
9.3.9.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 193
9.3.9.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 193
9.3.9.3 Removing the defective expansion card . . . . . . . . . . . 193
9.3.9.4 Installing the new expansion card . . . . . . . . . . . . . . 193
9.3.9.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 194
9.3.10 Replacing the riser card in riser module 1 . . . . . . . . . . . . 195
9.3.10.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 195
9.3.10.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 195
9.3.10.3 Removing the defective riser card . . . . . . . . . . . . . . 195
9.3.10.4 Installing the new riser card . . . . . . . . . . . . . . . . . 196
9.3.10.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 197
9.3.11 Replacing the riser card in riser module 2 . . . . . . . . . . . . 197
9.3.11.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 197
9.3.11.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 197
9.3.11.3 Removing the defective riser card . . . . . . . . . . . . . . 198
9.3.11.4 Installing the new riser card . . . . . . . . . . . . . . . . . 199
Upgrade and Maintenance Manual
RX200 S7
Contents
9.3.11.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 199
9.3.12 Replacing the riser card in riser module 3 . . . . . . . . . . . 200
9.3.12.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 200
9.3.12.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 200
9.3.12.3 Removing the defective riser card . . . . . . . . . . . . . . 201
9.3.12.4 Installing the new riser card . . . . . . . . . . . . . . . . . 202
9.3.12.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 202
9.3.13 Replacing TFM . . . . . . . . . . . . . . . . . . . . . . . . . 203
9.3.13.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 203
9.3.13.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 203
9.3.13.3 Removing the defective TFM . . . . . . . . . . . . . . . . 203
9.3.13.4 Installing the new TFM . . . . . . . . . . . . . . . . . . . 204
9.3.13.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 204
9.4 Backup units (BBU/FBU) . . . . . . . . . . . . . . . . . . . 205
9.4.1 Installing the BBU . . . . . . . . . . . . . . . . . . . . . . . . 205
9.4.1.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 205
9.4.1.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 205
9.4.1.3 Connecting the BBU cable to the BBU . . . . . . . . . . . 206
9.4.1.4 Installing the BBU in the holder . . . . . . . . . . . . . . . 207
9.4.1.5 Installing the BBU with the holder . . . . . . . . . . . . . . 208
9.4.1.6 Connecting the BBU cable to the RAID controller . . . . . . 209
9.4.1.7 Routing the BBU cable . . . . . . . . . . . . . . . . . . . 210
9.4.1.8 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 211
9.4.2 Installing the FBU . . . . . . . . . . . . . . . . . . . . . . . . 212
9.4.2.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 212
9.4.2.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 212
9.4.2.3 Installing the FBU in the holder . . . . . . . . . . . . . . . 213
9.4.2.4 Connecting the FBU cable to the FBU . . . . . . . . . . . 214
9.4.2.5 Installing the FBU with the holder . . . . . . . . . . . . . . 215
9.4.2.6 Installing TFM to the RAID controller (if applicable) . . . . . 216
9.4.2.7 Connecting the FBU cable to the RAID controller . . . . . . 217
9.4.2.8 Routing the FBU cable . . . . . . . . . . . . . . . . . . . 217
9.4.2.9 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 218
9.4.3 Removing the BBU . . . . . . . . . . . . . . . . . . . . . . . 219
9.4.3.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 219
9.4.3.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 219
9.4.3.3 Disconnecting the BBU cable from the RAID controller . . . 220
9.4.3.4 Removing the BBU with the holder . . . . . . . . . . . . . 221
9.4.3.5 Removing the BBU from the holder . . . . . . . . . . . . . 222
9.4.3.6 Disconnecting the BBU cable from the BBU . . . . . . . . 222
9.4.3.7 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 223
RX200 S7
Upgrade and Maintenance Manual
Contents
9.4.4 Removing the FBU . . . . . . . . . . . . . . . . . . . . . . . 223
9.4.4.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 223
9.4.4.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 224
9.4.4.3 Disconnecting the FBU cable from the RAID controller . . . 224
9.4.4.4 Removing the FBU with the holder . . . . . . . . . . . . . . 225
9.4.4.5 Disconnecting the FBU cable from the FBU . . . . . . . . . 226
9.4.4.6 Removing the FBU from the holder . . . . . . . . . . . . . 227
9.4.4.7 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 227
9.4.5 Replacing the BBU . . . . . . . . . . . . . . . . . . . . . . . 228
9.4.5.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 228
9.4.5.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 228
9.4.5.3 Removing the defective BBU . . . . . . . . . . . . . . . . 229
9.4.5.4 Installing the new BBU . . . . . . . . . . . . . . . . . . . . 229
9.4.5.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 229
9.4.6 Replacing the FBU . . . . . . . . . . . . . . . . . . . . . . . . 230
9.4.6.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . 231
9.4.6.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 231
9.4.6.3 Removing the defective FBU . . . . . . . . . . . . . . . . . 231
9.4.6.4 Installing the new FBU . . . . . . . . . . . . . . . . . . . . 231
9.4.6.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 232
10 Main memory . . . . . . . . . . . . . . . . . . . . . . . . . . 233
10.1 Basic information . . . . . . . . . . . . . . . . . . . . . . . 234
10.1.1 Memory sequence . . . . . . . . . . . . . . . . . . . . . . . . 236
10.1.1.1 Population rules . . . . . . . . . . . . . . . . . . . . . . . 236
10.1.1.2 Independant Channel mode . . . . . . . . . . . . . . . . . 237
10.1.1.3 Mirrored Channel and Performance modes . . . . . . . . . 238
10.1.1.4 Rank Sparing mode . . . . . . . . . . . . . . . . . . . . . 239
10.2 Installing a memory module . . . . . . . . . . . . . . . . . . 244
10.2.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . . 244
10.2.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 244
10.2.3 Selecting the memory slot . . . . . . . . . . . . . . . . . . . . 244
10.2.4 Installing a memory module . . . . . . . . . . . . . . . . . . . 245
10.2.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 245
10.3 Removing a memory module . . . . . . . . . . . . . . . . . 246
10.3.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . . 246
10.3.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 246
10.3.3 Removing a memory module . . . . . . . . . . . . . . . . . . 247
10.3.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 247
Upgrade and Maintenance Manual
RX200 S7
Contents
10.4 Replacing a memory module . . . . . . . . . . . . . . . . . 248
10.4.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . 248
10.4.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 248
10.4.3 Removing the defective memory module . . . . . . . . . . . . 248
10.4.4 Installing the new memory module . . . . . . . . . . . . . . . 249
10.4.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 249
11 Processors . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
11.1 Basic information . . . . . . . . . . . . . . . . . . . . . . . 252
11.1.1 Supported processors . . . . . . . . . . . . . . . . . . . . . 252
11.1.2 General equipping rules . . . . . . . . . . . . . . . . . . . . 252
11.2 Upgrading to dual processor configuration . . . . . . . . . 253
11.2.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . 253
11.2.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 254
11.2.3 Installing the processor . . . . . . . . . . . . . . . . . . . . . 254
11.2.4 Installing the heat sink . . . . . . . . . . . . . . . . . . . . . 260
11.2.5 Upgrading the main memory . . . . . . . . . . . . . . . . . . 262
11.2.6 Installing two additional fan modules . . . . . . . . . . . . . . 262
11.2.7 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 263
11.3 Replacing a processor . . . . . . . . . . . . . . . . . . . . 264
11.3.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . 264
11.3.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 264
11.3.3 Removing the heat sink . . . . . . . . . . . . . . . . . . . . . 265
11.3.4 Cleaning the heat sink underside and the processor surface . . 266
11.3.5 Removing the defective processor . . . . . . . . . . . . . . . 266
11.3.6 Installing the new processor . . . . . . . . . . . . . . . . . . 270
11.3.7 Applying the thermal paste to the processor surface . . . . . . 272
11.3.8 Installing the heat sink . . . . . . . . . . . . . . . . . . . . . 275
11.3.9 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 276
11.4 Replacing a heat sink . . . . . . . . . . . . . . . . . . . . . 277
11.4.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . 277
11.4.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 277
11.4.3 Removing the defective heat sink . . . . . . . . . . . . . . . . 277
11.4.4 Cleaning the processor surface . . . . . . . . . . . . . . . . . 277
11.4.5 Installing the new heat sink . . . . . . . . . . . . . . . . . . . 278
11.4.6 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 278
RX200 S7
Upgrade and Maintenance Manual
Contents
12 Optical disk drive . . . . . . . . . . . . . . . . . . . . . . . . 279
12.1 Basic information . . . . . . . . . . . . . . . . . . . . . . . 280
12.2 Installing the ODD . . . . . . . . . . . . . . . . . . . . . . . 280
12.2.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . . 280
12.2.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 280
12.2.3 Removing the dummy module . . . . . . . . . . . . . . . . . . 281
12.2.4 Installing the ODD . . . . . . . . . . . . . . . . . . . . . . . . 282
12.2.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 283
12.3 Removing the ODD . . . . . . . . . . . . . . . . . . . . . . . 284
12.3.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . . 284
12.3.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 284
12.3.3 Removing the ODD . . . . . . . . . . . . . . . . . . . . . . . 285
12.3.4 Installing the dummy module . . . . . . . . . . . . . . . . . . 287
12.3.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 288
12.4 Replacing the ODD . . . . . . . . . . . . . . . . . . . . . . . 288
12.4.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . . 288
12.4.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 288
12.4.3 Removing the defective ODD . . . . . . . . . . . . . . . . . . 289
12.4.4 Installing the new ODD . . . . . . . . . . . . . . . . . . . . . 289
12.4.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 289
13 Front panel and front VGA/LAN module . . . . . . . . . . . 291
13.1 Basic information . . . . . . . . . . . . . . . . . . . . . . . 291
13.2 Installing the front VGA and/or front LAN . . . . . . . . . . 292
13.2.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . . 292
13.2.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 292
13.2.3 Removing the front VGA/LAN module . . . . . . . . . . . . . . 293
13.2.4 Removing the covers . . . . . . . . . . . . . . . . . . . . . . 294
13.2.5 Installing the front VGA connector . . . . . . . . . . . . . . . . 294
13.2.6 Installing the front LAN connector . . . . . . . . . . . . . . . . 295
13.2.7 Installing the front VGA/LAN module . . . . . . . . . . . . . . 298
13.2.8 Connecting the front VGA cable . . . . . . . . . . . . . . . . . 299
13.2.9 Connecting the front LAN cable . . . . . . . . . . . . . . . . . 299
13.2.10 Installing the front LAN card . . . . . . . . . . . . . . . . . . . 300
13.2.11 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 300
13.2.12 Using the front management LAN connector . . . . . . . . . . 301
Upgrade and Maintenance Manual
RX200 S7
Contents
13.3 Removing the front VGA and/or front LAN . . . . . . . . . 302
13.3.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . 302
13.3.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 302
13.3.3 Removing the front LAN card . . . . . . . . . . . . . . . . . . 303
13.3.4 Disconnecting the front LAN cable . . . . . . . . . . . . . . . 303
13.3.5 Disconnecting the front VGA cable . . . . . . . . . . . . . . . 304
13.3.6 Removing the front VGA/LAN module . . . . . . . . . . . . . 304
13.3.7 Removing the front LAN connector . . . . . . . . . . . . . . . 305
13.3.8 Removing the front VGA connector . . . . . . . . . . . . . . . 307
13.3.9 Installing the front VGA/LAN module . . . . . . . . . . . . . . 308
13.3.10 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 308
13.4 Replacing the front VGA cable and/or front LAN cable . . . 309
13.4.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . 309
13.4.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 309
13.4.3 Removing the defective front VGA cable and/or front
LAN cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310
13.4.4 Installing the new front VGA cable and/or front LAN cable . . . 310
13.4.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 311
13.5 Replacing the front LAN card . . . . . . . . . . . . . . . . . 312
13.5.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . 312
13.5.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 312
13.5.3 Removing the defective front LAN card . . . . . . . . . . . . . 312
13.5.4 Installing the new front LAN card . . . . . . . . . . . . . . . . 313
13.5.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 313
13.6 Replacing the front panel board . . . . . . . . . . . . . . . 314
13.6.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . 314
13.6.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 315
13.6.3 Removing the defective front panel board . . . . . . . . . . . 315
13.6.4 Installing the new front panel module . . . . . . . . . . . . . . 319
13.6.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 323
14 Serial interface . . . . . . . . . . . . . . . . . . . . . . . . . 325
14.1 Basic information . . . . . . . . . . . . . . . . . . . . . . . 325
14.2 Installing the serial interface . . . . . . . . . . . . . . . . . 325
14.2.1 Required tools . . . . . . . . . . . . . . . . . . . . . . . . . 326
14.2.2 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 326
14.2.3 Removing the slot cover . . . . . . . . . . . . . . . . . . . . 326
14.2.4 Installing the serial interface . . . . . . . . . . . . . . . . . . 327
/