Fujitsu PRIMERGY RX2510 M2 User manual

Category
Servers
Type
User manual
Upgrade and Maintenance Manual - English
FUJITSU Server PRIMERGY RX2510 M2
Upgrade and Maintenance Manual
June 2017
CommentsSuggestionsCorrections
The User Documentation Department would like to
know your opinion of this manual. Your feedback helps
us optimize our documentation to suit your individual
needs.
Feel free to send us your comments by e-mail to
Certified documentation
according to DIN EN ISO 9001:2008
To ensure a consistently high quality standard and
user-friendliness, this documentation was created to
meet the regulations of a quality management system
which complies with the requirements of the standard
DIN EN ISO 9001:2008.
cognitas. Gesellschaft für Technik-Dokumentation mbH
www.cognitas.de
Copyright and Trademarks
Copyright 2017 FUJITSU LIMITED
All rights reserved.
Delivery subject to availability; right of technical modifications reserved.
All hardware and software names used are trademarks of their respective manufacturers.
The contents of this manual may be revised without prior notice.
Fujitsu assumes no liability for damages to third party copyrights or other rights arising from
the use of any information in this manual.
No part of this manual may be reproduced in any form without the prior written permission
of Fujitsu.
Microsoft, Windows, Windows Server, and Hyper-V are trademarks or registered trademarks of
Microsoft Corporation in the USA and other countries.
Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries
in the USA and other countries.
RX2510 M2 Upgrade and Maintenance Manual
Before reading this manual
For your safety
This manual contains important information for safely and correctly using this
product.
Carefully read the manual before using this product. Pay particular attention to
the accompanying manual "Safety Notes and Regulations" and ensure these
safety notes are understood before using the product. Keep this manual and the
manual "Safety Notes and Regulations" in a safe place for easy reference while
using this product.
Radio interference
This product is a "Class A" ITE (Information Technology Equipment). In a
domestic environment this product may cause radio interference, in which case
the user may be required to take appropriate measures. VCCI-A
Aluminum electrolytic capacitors
The aluminum electrolytic capacitors used in the product's printed circuit board
assemblies and in the mouse and keyboard are limited-life components. Use of
these components beyond their operating life may result in electrolyte leakage
or depletion, potentially causing emission of foul odor or smoke.
As a guideline, in a normal office environment (25°C) operating life is not
expected to be reached within the maintenance support period (5 years).
However, operating life may be reached more quickly if, for example, the
product is used in a hot environment. The customer shall bear the cost of
replacing replaceable components which have exceeded their operating life.
Note that these are only guidelines, and do not constitute a guarantee of
trouble-free operation during the maintenance support period.
High safety use
This product has been designed and manufactured to be used in commercial
and/or industrial areas as a server.
When used as visual display workplace, it must not be placed in the direct field
of view to avoid incommoding reflections (applies only to TX server systems).
The device has not been designed or manufactured for uses which demand an
extremely high level of safety and carry a direct and serious risk of life or body
if such safety cannot be assured.
Upgrade and Maintenance Manual RX2510 M2
These uses include control of nuclear reactions in nuclear power plants,
automatic airplane flight control, air traffic control, traffic control in mass
transport systems, medical devices for life support, and missile guidance
control in weapons systems (hereafter, "high safety use"). Customers should
not use this product for high safety use unless measures are in place for
ensuring the level of safety demanded of such use. Please consult the sales
staff of Fujitsu if intending to use this product for high safety use.
Measures against momentary voltage drop
This product may be affected by a momentary voltage drop in the power supply
caused by lightning. To prevent a momentary voltage drop, use of an AC
uninterruptible power supply is recommended.
(This notice follows the guidelines of Voltage Dip Immunity of Personal
Computer issued by JEITA, the Japan Electronics and Information Technology
Industries Association.)
Technology controlled by the Foreign Exchange and Foreign Trade
Control Law of Japan
Documents produced by Fujitsu may contain technology controlled by the
Foreign Exchange and Foreign Trade Control Law of Japan. Documents which
contain such technology should not be exported from Japan or transferred to
non-residents of Japan without first obtaining authorization in accordance with
the above law.
Harmonic Current Standards
This product conforms to harmonic current standard JIS C 61000-3-2.
Only for Japan: About SATA HDDs
The SATA version of this server supports HDDs with SATA / BC-SATA storage
interfaces. Please note that the usage and operation conditions differ
depending on the type of HDD used.
Please refer to the following internet address for further information on the
usage and operation conditions of each available type of HDD:
http://jp.fujitsu.com/platform/server/primergy/harddisk/
RX2510 M2 Upgrade and Maintenance Manual
Only for Japan:
Shielded LAN cables should be used in this product.
Only for Japan:
IAlthough described in this manual, some sections do not apply for Japan.
These options and routines include:
Trusted Platform Module (TPM)
Upgrade and Maintenance Manual RX2510 M2
Version history
Issue number Reason for update
1.0 / March 2016 Initial release
2.0 / October 2016 ODD added, TPM added, changes caused by the
manual review list, controls and indicators reworked
3.0 / June 2017 8x SSF added, UFM added, ODD added, the last
agreements to standardize the documents added
RX2510 M2 Upgrade and Maintenance Manual
Contents
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
1.1 Notational conventions . . . . . . . . . . . . . . . . . . . . 20
2 Before you start . . . . . . . . . . . . . . . . . . . . . . . . 21
2.1 Classification of procedures . . . . . . . . . . . . . . . . . 23
2.1.1 Customer Replaceable Units (CRU) . . . . . . . . . . . . . . . 23
2.1.2 Upgrade and Repair Units (URU) . . . . . . . . . . . . . . . . 24
2.1.3 Field Replaceable Units (FRU) . . . . . . . . . . . . . . . . . 25
2.2 Average task duration . . . . . . . . . . . . . . . . . . . . . 26
2.3 Tools you need at hand . . . . . . . . . . . . . . . . . . . . 27
2.4 Documents you need at hand . . . . . . . . . . . . . . . . . 31
3 Important information . . . . . . . . . . . . . . . . . . . . . 33
3.1 Safety instructions . . . . . . . . . . . . . . . . . . . . . . . 33
3.2 ENERGY STAR . . . . . . . . . . . . . . . . . . . . . . . . . 42
3.3 CE conformity . . . . . . . . . . . . . . . . . . . . . . . . . 42
3.4 FCC Class A Compliance Statement . . . . . . . . . . . . . 43
3.5 Environmental protection . . . . . . . . . . . . . . . . . . . 44
4 Basic hardware procedures . . . . . . . . . . . . . . . . . . 47
4.1 Using diagnostics information . . . . . . . . . . . . . . . . 47
4.1.1 Locating the defective server . . . . . . . . . . . . . . . . . . 47
4.1.2 Determining the error class . . . . . . . . . . . . . . . . . . . 48
4.1.2.1 Global Error indicator . . . . . . . . . . . . . . . . . . . . 48
4.1.2.2 Customer Self Service (CSS) indicator . . . . . . . . . . . 48
4.1.3 Locating the defective component . . . . . . . . . . . . . . . . 49
4.1.3.1 Local diagnostic indicators on the front . . . . . . . . . . . 49
4.1.3.2 Local diagnostic indicators on the system board . . . . . . . 49
4.2 Shutting down the server . . . . . . . . . . . . . . . . . . . 50
Upgrade and Maintenance Manual RX2510 M2
Contents
4.3 Disconnecting the power cord . . . . . . . . . . . . . . . . . 51
4.4 Getting access to the component . . . . . . . . . . . . . . . 52
4.4.1 Extending the server out of the rack . . . . . . . . . . . . . . . 53
4.4.2 Removing the server from the rack . . . . . . . . . . . . . . . . 54
4.4.3 Removing the top covers . . . . . . . . . . . . . . . . . . . . . 56
4.5 Reassembling . . . . . . . . . . . . . . . . . . . . . . . . . . 57
4.5.1 Installing the top covers . . . . . . . . . . . . . . . . . . . . . . 57
4.5.2 Installing the server in the rack . . . . . . . . . . . . . . . . . . 60
4.5.3 Sliding the server into the rack . . . . . . . . . . . . . . . . . . 62
4.6 Connecting the power cord . . . . . . . . . . . . . . . . . . . 63
4.7 Switching on the server . . . . . . . . . . . . . . . . . . . . . 65
4.8 Handling riser modules . . . . . . . . . . . . . . . . . . . . . 66
4.8.1 Removing a riser module . . . . . . . . . . . . . . . . . . . . . 67
4.8.2 Installing a riser module . . . . . . . . . . . . . . . . . . . . . . 67
4.9 Handling chassis sponges . . . . . . . . . . . . . . . . . . . 69
4.9.1 Removing the chassis sponges . . . . . . . . . . . . . . . . . . 70
4.9.2 Installing the chassis sponges . . . . . . . . . . . . . . . . . . 71
4.10 Handling CPU air ducts . . . . . . . . . . . . . . . . . . . . . 72
4.10.1 Removing the CPU air ducts . . . . . . . . . . . . . . . . . . . 72
4.10.2 Installing the CPU air ducts . . . . . . . . . . . . . . . . . . . . 73
5 Basic software procedures . . . . . . . . . . . . . . . . . . . 75
5.1 Starting the maintenance task . . . . . . . . . . . . . . . . . 75
5.1.1 Suspending BitLocker functionality . . . . . . . . . . . . . . . . 75
5.1.2 Disabling SVOM boot watchdog functionality . . . . . . . . . . . 76
5.1.2.1 Viewing boot watchdog settings . . . . . . . . . . . . . . . . 76
5.1.2.2 Configuring boot watchdog settings . . . . . . . . . . . . . . 77
5.1.3 Removing backup and optical disk media . . . . . . . . . . . . 78
5.1.4 Verifying and configuring the backup software solution . . . . . . 79
5.1.5 Switching on the ID indicator . . . . . . . . . . . . . . . . . . . 79
5.2 Completing the maintenance task . . . . . . . . . . . . . . . 80
5.2.1 Updating or recovering the system board BIOS and iRMC . . . . 80
5.2.1.1 Updating or recovering the system board BIOS . . . . . . . . 80
5.2.1.2 Updating or recovering the iRMC . . . . . . . . . . . . . . . 80
5.2.2 Verifying system information backup / restore . . . . . . . . . . 82
5.2.3 Updating expansion card firmware . . . . . . . . . . . . . . . . 82
5.2.4 Enabling Option ROM scan . . . . . . . . . . . . . . . . . . . . 84
RX2510 M2 Upgrade and Maintenance Manual
Contents
5.2.5 Reconfiguring the backup software solution . . . . . . . . . . . 85
5.2.6 Resetting the boot retry counter . . . . . . . . . . . . . . . . . 85
5.2.6.1 Viewing the boot retry counter . . . . . . . . . . . . . . . . 85
5.2.6.2 Resetting the boot retry counter . . . . . . . . . . . . . . . 86
5.2.7 Resetting the error status after replacing memory modules
or CPUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
5.2.7.1 Memory modules . . . . . . . . . . . . . . . . . . . . . . . 87
5.2.7.2 CPUs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
5.2.8 Enabling SVOM boot watchdog functionality . . . . . . . . . . 90
5.2.9 Enabling replaced components in the system BIOS . . . . . . . 91
5.2.10 Verifying the memory mode . . . . . . . . . . . . . . . . . . . 92
5.2.11 Verifying the system time settings . . . . . . . . . . . . . . . . 92
5.2.12 Viewing and clearing the System Event Log (SEL) . . . . . . . 93
5.2.12.1 Viewing the SEL . . . . . . . . . . . . . . . . . . . . . . . 93
5.2.12.2 Clearing the SEL . . . . . . . . . . . . . . . . . . . . . . . 94
5.2.13 Updating the NIC configuration file in a Linux and VMware
environment . . . . . . . . . . . . . . . . . . . . . . . . . . . 94
5.2.14 Resuming BitLocker functionality . . . . . . . . . . . . . . . . 96
5.2.15 Performing a RAID array rebuild . . . . . . . . . . . . . . . . . 97
5.2.16 Looking up changed MAC / WWN addresses . . . . . . . . . . 97
5.2.16.1 Looking up MAC addresses . . . . . . . . . . . . . . . . . 98
5.2.16.2 Looking up WWN addresses . . . . . . . . . . . . . . . . . 98
5.2.17 Using the Chassis ID Prom Tool . . . . . . . . . . . . . . . . . 99
5.2.18 Configuring LAN teaming . . . . . . . . . . . . . . . . . . . . 100
5.2.18.1 After replacing / upgrading LAN controllers . . . . . . . . . 100
5.2.18.2 After replacing a system board . . . . . . . . . . . . . . . . 100
5.2.19 Switching off the ID indicator . . . . . . . . . . . . . . . . . . 101
5.2.20 Performing a fan test . . . . . . . . . . . . . . . . . . . . . . 101
6 Power supply unit (PSU) . . . . . . . . . . . . . . . . . . . . 103
6.1 Basic information . . . . . . . . . . . . . . . . . . . . . . . 103
6.1.1 PSU configurations . . . . . . . . . . . . . . . . . . . . . . . 104
6.1.2 Assembly rules . . . . . . . . . . . . . . . . . . . . . . . . . 104
6.2 Redundant power supply . . . . . . . . . . . . . . . . . . . 105
6.2.1 Installing a PSU . . . . . . . . . . . . . . . . . . . . . . . . . 105
6.2.1.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 105
6.2.1.2 Removing the dummy cover . . . . . . . . . . . . . . . . . 105
6.2.1.3 Installing a PSU . . . . . . . . . . . . . . . . . . . . . . . 106
6.2.1.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 107
6.2.2 Removing a PSU . . . . . . . . . . . . . . . . . . . . . . . . 108
Upgrade and Maintenance Manual RX2510 M2
Contents
6.2.2.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 108
6.2.2.2 Note for servers using CMA (Cable Management Arm) . . . 108
6.2.2.3 Removing a PSU . . . . . . . . . . . . . . . . . . . . . . 110
6.2.2.4 Installing the dummy cover . . . . . . . . . . . . . . . . . 111
6.2.3 Replacing a PSU . . . . . . . . . . . . . . . . . . . . . . . . 111
6.2.3.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 112
6.2.3.2 Note for servers using CMA (Cable Management Arm) . . . 112
6.2.3.3 Removing the defective PSU . . . . . . . . . . . . . . . . 112
6.2.3.4 Installing the new PSU . . . . . . . . . . . . . . . . . . . 113
6.2.3.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 113
7 Hard disk drive (HDD) and solid state drive (SSD) . . . . . 115
7.1 Basic information . . . . . . . . . . . . . . . . . . . . . . . 116
7.2 Handling HDDs or SSDs without installation frame . . . . . 117
7.2.1 2.5-inch HDD/SSD and 2.5-inch installation frame . . . . . . . 117
7.2.2 2.5-inch HDD/SSD and 3.5-inch installation frame . . . . . . . 119
7.2.3 3.5-inch HDD and 3.5-inch installation frame . . . . . . . . . . 121
7.3 2.5-inch HDD/SSD configurations . . . . . . . . . . . . . . 123
7.3.1 Equipping the 2.5-inch HDD/SSD bays . . . . . . . . . . . . . 123
7.3.2 Configuration with up to four HDD/SSD modules . . . . . . . . 124
7.3.3 Configuration with up to eight HDD/SSD modules . . . . . . . 125
7.3.4 Installing 2.5-inch HDD/SSD modules . . . . . . . . . . . . . 127
7.3.4.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 127
7.3.4.2 Removing a 2.5-inch HDD/SSD dummy module . . . . . . 127
7.3.4.3 Installing a 2.5-inch HDD/SSD module . . . . . . . . . . . 128
7.3.4.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 129
7.3.5 Removing 2.5-inch HDD/SSD modules . . . . . . . . . . . . . 130
7.3.5.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 130
7.3.5.2 Removing a 2.5-inch HDD/SSD module . . . . . . . . . . 131
7.3.5.3 Installing a 2.5-inch HDD/SSD dummy module . . . . . . . 131
7.3.5.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 131
7.3.6 Replacing a 2.5-inch HDD/SSD module . . . . . . . . . . . . 132
7.3.6.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 132
7.3.6.2 Removing the defective 2.5-inch HDD/SSD module . . . . 133
7.3.6.3 Installing the new 2.5-inch HDD/SSD module . . . . . . . . 133
7.3.6.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 133
7.3.7 Replacing the 4 x 2.5-inch HDD backplane . . . . . . . . . . . 133
7.3.7.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 133
7.3.7.2 Removing the defective 4 x 2.5-inch HDD backplane . . . . 134
RX2510 M2 Upgrade and Maintenance Manual
Contents
7.3.7.3 Installing the new 4 x 2.5-inch HDD backplane . . . . . . . 136
7.3.7.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 139
7.3.8 Upgrading configuration from up to four to up to eight 2.5-inch
HDDs/SSDs . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
7.3.8.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 140
7.3.8.2 Installing the second HDD backplane . . . . . . . . . . . . 140
7.3.8.3 Installing additional HDD/SSD modules . . . . . . . . . . . 141
7.3.8.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 141
7.4 3.5-inch HDD configurations . . . . . . . . . . . . . . . . . 142
7.4.1 Equipping the 3.5-inch HDD bays . . . . . . . . . . . . . . . . 142
7.4.2 Installing 3.5-inch HDD modules . . . . . . . . . . . . . . . . 143
7.4.2.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 143
7.4.2.2 Removing a 3.5-inch HDD dummy module . . . . . . . . . 143
7.4.2.3 Installing a 3.5-inch HDD module . . . . . . . . . . . . . . 144
7.4.2.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 145
7.4.3 Removing 3.5-inch HDD modules . . . . . . . . . . . . . . . . 145
7.4.3.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 145
7.4.3.2 Removing a 3.5-inch HDD module . . . . . . . . . . . . . . 146
7.4.3.3 Installing a 3.5-inch dummy module . . . . . . . . . . . . . 146
7.4.3.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 147
7.4.4 Replacing a 3.5-inch HDD module . . . . . . . . . . . . . . . 147
7.4.4.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 148
7.4.4.2 Removing the defective 3.5-inch HDD module . . . . . . . 148
7.4.4.3 Installing the new 3.5-inch HDD module . . . . . . . . . . . 148
7.4.4.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 148
7.4.5 Replacing the 3.5-inch HDD backplane . . . . . . . . . . . . . 148
7.4.5.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 148
7.4.5.2 Removing the defective 3.5-inch HDD backplane . . . . . . 149
7.4.5.3 Installing the new 3.5-inch HDD backplane . . . . . . . . . 150
7.4.5.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 151
8 Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
8.1 Basic information . . . . . . . . . . . . . . . . . . . . . . . 153
8.1.1 Numbering of the fan modules . . . . . . . . . . . . . . . . . . 154
8.2 Replacing a defective fan module . . . . . . . . . . . . . . . 156
8.2.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 156
8.2.2 Removing the defective fan module . . . . . . . . . . . . . . . 156
8.2.3 Installing the new fan module . . . . . . . . . . . . . . . . . . 157
8.2.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 158
Upgrade and Maintenance Manual RX2510 M2
Contents
9 Expansion cards and backup units . . . . . . . . . . . . . 159
9.1 Basic information . . . . . . . . . . . . . . . . . . . . . . . 160
9.1.1 Equipping the PCIe slots . . . . . . . . . . . . . . . . . . . . 160
9.2 Handling slot brackets . . . . . . . . . . . . . . . . . . . . 163
9.2.1 Installing a slot bracket . . . . . . . . . . . . . . . . . . . . . 163
9.2.2 Removing a slot bracket . . . . . . . . . . . . . . . . . . . . 165
9.2.2.1 Removing the slot bracket . . . . . . . . . . . . . . . . . . 165
9.3 Handling SFP+ transceiver modules . . . . . . . . . . . . . 166
9.3.1 Installing SFP+ transceiver modules . . . . . . . . . . . . . . 166
9.3.2 Removing an SFP+ transceiver module . . . . . . . . . . . . 169
9.4 Expansion cards and riser cards . . . . . . . . . . . . . . . 172
9.4.1 Installing an expansion card . . . . . . . . . . . . . . . . . . 173
9.4.1.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 173
9.4.1.2 Removing the slot cover (only slot 2-4) . . . . . . . . . . . 174
9.4.1.3 Installing the expansion card . . . . . . . . . . . . . . . . 174
9.4.1.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 176
9.4.2 Removing an expansion card . . . . . . . . . . . . . . . . . . 176
9.4.2.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 176
9.4.2.2 Removing the expansion card . . . . . . . . . . . . . . . . 177
9.4.2.3 Installing the slot cover (only slot 2-4) . . . . . . . . . . . . 177
9.4.2.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 178
9.4.3 Replacing an expansion card . . . . . . . . . . . . . . . . . . 178
9.4.3.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 178
9.4.3.2 Removing the defective expansion card . . . . . . . . . . 179
9.4.3.3 Installing the new expansion card . . . . . . . . . . . . . . 179
9.4.3.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 179
9.4.4 Replacing a riser card . . . . . . . . . . . . . . . . . . . . . . 180
9.4.4.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 180
9.4.4.2 Removing the defective riser card . . . . . . . . . . . . . . 180
9.4.4.3 Installing the new riser card . . . . . . . . . . . . . . . . . 181
9.4.4.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 182
9.4.5 Replacing a TFM . . . . . . . . . . . . . . . . . . . . . . . . 182
9.4.5.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 182
9.4.5.2 Removing the defective TFM . . . . . . . . . . . . . . . . 183
9.4.5.3 Installing the new TFM . . . . . . . . . . . . . . . . . . . 184
9.4.5.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 185
9.4.6 Upgrading to the full height riser module . . . . . . . . . . . . 186
9.4.6.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 186
9.4.6.2 Installing the upgrade kit . . . . . . . . . . . . . . . . . . 187
RX2510 M2 Upgrade and Maintenance Manual
Contents
9.5 Flash Backup unit . . . . . . . . . . . . . . . . . . . . . . . 190
9.5.1 Installing an FBU . . . . . . . . . . . . . . . . . . . . . . . . 190
9.5.1.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 190
9.5.1.2 Preparing the FBU . . . . . . . . . . . . . . . . . . . . . . 191
9.5.1.3 Installing the FBU adapter plate . . . . . . . . . . . . . . . 192
9.5.1.4 Installing the FBU . . . . . . . . . . . . . . . . . . . . . . 194
9.5.1.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 195
9.5.2 Removing an FBU . . . . . . . . . . . . . . . . . . . . . . . . 196
9.5.2.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 196
9.5.2.2 Removing the FBU with the holder . . . . . . . . . . . . . . 196
9.5.2.3 Disconnecting the FBU cable from the FBU . . . . . . . . . 197
9.5.2.4 Removing the FBU from the holder . . . . . . . . . . . . . 197
9.5.2.5 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 198
9.5.3 Replacing an FBU . . . . . . . . . . . . . . . . . . . . . . . . 198
9.5.3.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 198
9.5.3.2 Removing the defective FBU . . . . . . . . . . . . . . . . . 198
9.5.3.3 Installing the new FBU . . . . . . . . . . . . . . . . . . . . 199
9.5.3.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 199
10 Main memory . . . . . . . . . . . . . . . . . . . . . . . . . . 201
10.1 Basic information . . . . . . . . . . . . . . . . . . . . . . . 202
10.1.1 Population rules . . . . . . . . . . . . . . . . . . . . . . . . . 203
10.1.2 Modes of operation . . . . . . . . . . . . . . . . . . . . . . . 204
10.1.2.1 Independent Channel mode . . . . . . . . . . . . . . . . . 204
10.1.2.2 Performance mode . . . . . . . . . . . . . . . . . . . . . . 204
10.2 Installing a memory module . . . . . . . . . . . . . . . . . . 205
10.2.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 205
10.2.2 Selecting the memory slot . . . . . . . . . . . . . . . . . . . . 205
10.2.3 Installing a memory module . . . . . . . . . . . . . . . . . . . 206
10.2.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 206
10.3 Removing a memory module . . . . . . . . . . . . . . . . . 207
10.3.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 207
10.3.2 Removing a memory module . . . . . . . . . . . . . . . . . . 207
10.3.3 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 208
10.4 Replacing a memory module . . . . . . . . . . . . . . . . . 208
10.4.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 208
10.4.2 Removing the defective memory module . . . . . . . . . . . . 208
10.4.3 Installing the new memory module . . . . . . . . . . . . . . . 208
10.4.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 209
Upgrade and Maintenance Manual RX2510 M2
Contents
11 Processor (CPU) . . . . . . . . . . . . . . . . . . . . . . . . 211
11.1 Basic information . . . . . . . . . . . . . . . . . . . . . . . 212
11.1.1 Supported CPUs . . . . . . . . . . . . . . . . . . . . . . . . 213
11.2 Upgrading to 2 CPU configuration . . . . . . . . . . . . . . 213
11.2.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 214
11.2.2 Installing the CPU . . . . . . . . . . . . . . . . . . . . . . . . 214
11.2.3 Installing the heat sink . . . . . . . . . . . . . . . . . . . . . 220
11.2.4 Upgrading the main memory . . . . . . . . . . . . . . . . . . 221
11.2.5 Installing three additional fan modules . . . . . . . . . . . . . 221
11.2.6 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 222
11.3 Replacing a CPU . . . . . . . . . . . . . . . . . . . . . . . . 223
11.3.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 223
11.3.2 Removing the heat sink . . . . . . . . . . . . . . . . . . . . . 224
11.3.3 Removing the defective CPU . . . . . . . . . . . . . . . . . . 225
11.3.4 Installing the new CPU . . . . . . . . . . . . . . . . . . . . . 228
11.3.5 Applying the thermal paste to the CPU surface . . . . . . . . . 228
11.3.6 Installing the heat sink . . . . . . . . . . . . . . . . . . . . . 229
11.3.7 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 230
11.4 Replacing the heat sink . . . . . . . . . . . . . . . . . . . . 231
11.4.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 231
11.4.2 Removing the defective heat sink . . . . . . . . . . . . . . . . 231
11.4.3 Installing the new heat sink . . . . . . . . . . . . . . . . . . . 231
11.4.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 232
12 Accessible drives . . . . . . . . . . . . . . . . . . . . . . . 233
12.1 Optical disk drive (ODD) . . . . . . . . . . . . . . . . . . . 234
12.1.1 Basic information . . . . . . . . . . . . . . . . . . . . . . . . 234
12.1.2 Installing the ODD . . . . . . . . . . . . . . . . . . . . . . . 236
12.1.2.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 236
12.1.2.2 Removing the dummy cover . . . . . . . . . . . . . . . . 237
12.1.2.3 Installing the ODD . . . . . . . . . . . . . . . . . . . . . . 237
12.1.2.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 239
12.1.3 Removing the ODD . . . . . . . . . . . . . . . . . . . . . . . 240
12.1.3.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 240
12.1.3.2 Removing the ODD . . . . . . . . . . . . . . . . . . . . . 240
12.1.3.3 Installing the dummy cover . . . . . . . . . . . . . . . . . 242
12.1.3.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 242
12.1.4 Replacing the ODD . . . . . . . . . . . . . . . . . . . . . . . 243
RX2510 M2 Upgrade and Maintenance Manual
Contents
12.1.4.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 243
12.1.4.2 Removing the defective ODD . . . . . . . . . . . . . . . . 243
12.1.4.3 Installing the new ODD . . . . . . . . . . . . . . . . . . . . 243
12.1.4.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 243
13 Front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
13.1 Basic information . . . . . . . . . . . . . . . . . . . . . . . 245
13.2 Front panel module . . . . . . . . . . . . . . . . . . . . . . . 246
13.2.1 Replacing the front panel module . . . . . . . . . . . . . . . . 246
13.2.1.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 246
13.2.1.2 Removing the front panel module . . . . . . . . . . . . . . 247
13.2.1.3 Installing the front panel module . . . . . . . . . . . . . . . 249
13.2.1.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 250
14 Serial interface . . . . . . . . . . . . . . . . . . . . . . . . . 251
14.1 Installing the serial interface . . . . . . . . . . . . . . . . . 251
14.1.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 251
14.1.2 Removing the dummy cover . . . . . . . . . . . . . . . . . . 252
14.1.3 Installing the serial interface . . . . . . . . . . . . . . . . . . . 252
14.1.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 253
14.2 Removing the serial interface . . . . . . . . . . . . . . . . . 254
14.2.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 254
14.2.2 Removing the serial interface . . . . . . . . . . . . . . . . . . 254
14.2.3 Installing the dummy cover . . . . . . . . . . . . . . . . . . . 255
14.2.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 255
14.3 Replacing the serial interface . . . . . . . . . . . . . . . . . 255
14.3.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . . 255
14.3.2 Removing the defective serial interface . . . . . . . . . . . . . 256
14.3.3 Installing the new serial interface . . . . . . . . . . . . . . . . 256
14.3.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . . 256
Upgrade and Maintenance Manual RX2510 M2
Contents
15 System board and components . . . . . . . . . . . . . . . 257
15.1 Basic information . . . . . . . . . . . . . . . . . . . . . . . 257
15.2 CMOS battery . . . . . . . . . . . . . . . . . . . . . . . . . 258
15.2.1 Replacing the CMOS battery . . . . . . . . . . . . . . . . . . 258
15.2.1.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 259
15.2.1.2 Replacing the defective CMOS battery . . . . . . . . . . . 259
15.2.1.3 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 260
15.3 USB Flash Module (UFM) . . . . . . . . . . . . . . . . . . . 260
15.3.1 Installing the UFM . . . . . . . . . . . . . . . . . . . . . . . . 260
15.3.1.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 260
15.3.1.2 Installing the UFM . . . . . . . . . . . . . . . . . . . . . . 261
15.3.1.3 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 262
15.3.1.4 Software configuration . . . . . . . . . . . . . . . . . . . 262
15.3.2 Removing the UFM . . . . . . . . . . . . . . . . . . . . . . . 263
15.3.2.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 263
15.3.2.2 Removing the UFM . . . . . . . . . . . . . . . . . . . . . 264
15.3.2.3 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 264
15.3.3 Replacing the UFM . . . . . . . . . . . . . . . . . . . . . . . 265
15.3.3.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 265
15.3.3.2 Removing the defective UFM . . . . . . . . . . . . . . . . 265
15.3.3.3 Installing the new UFM . . . . . . . . . . . . . . . . . . . 266
15.3.3.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 267
15.3.3.5 Software configuration . . . . . . . . . . . . . . . . . . . 267
15.4 Trusted Platform Module (TPM) . . . . . . . . . . . . . . . . 268
15.4.1 Installing the TPM . . . . . . . . . . . . . . . . . . . . . . . . 268
15.4.1.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 268
15.4.1.2 Installing the TPM . . . . . . . . . . . . . . . . . . . . . . 269
15.4.1.3 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 271
15.4.2 Removing the TPM . . . . . . . . . . . . . . . . . . . . . . . 272
15.4.2.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 272
15.4.2.2 Removing the TPM . . . . . . . . . . . . . . . . . . . . . 273
15.4.2.3 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 275
15.4.3 Replacing the TPM . . . . . . . . . . . . . . . . . . . . . . . 276
15.4.3.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . 276
15.4.3.2 Removing the defective TPM . . . . . . . . . . . . . . . . 276
15.4.3.3 Installing the new TPM . . . . . . . . . . . . . . . . . . . 277
15.4.3.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . 277
15.5 SATA DOM . . . . . . . . . . . . . . . . . . . . . . . . . . . 278
15.5.1 Installing the SATA DOM . . . . . . . . . . . . . . . . . . . . 278
RX2510 M2 Upgrade and Maintenance Manual
Contents
15.5.1.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 278
15.5.1.2 Installing the SATA DOM . . . . . . . . . . . . . . . . . . . 278
15.5.1.3 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 279
15.5.2 Removing the SATA DOM . . . . . . . . . . . . . . . . . . . . 280
15.5.2.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 280
15.5.2.2 Removing the SATA DOM . . . . . . . . . . . . . . . . . . 280
15.5.2.3 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 280
15.5.3 Replacing the SATA DOM . . . . . . . . . . . . . . . . . . . . 281
15.5.3.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 281
15.5.3.2 Replacing the SATA DOM . . . . . . . . . . . . . . . . . . 281
15.5.3.3 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 281
15.6 iRMC microSD card . . . . . . . . . . . . . . . . . . . . . . 282
15.6.1 Installing the iRMC microSD card . . . . . . . . . . . . . . . . 282
15.6.1.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 282
15.6.1.2 Installing the iRMC microSD card . . . . . . . . . . . . . . 282
15.6.1.3 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 283
15.6.2 Removing the iRMC microSD card . . . . . . . . . . . . . . . 284
15.6.2.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 284
15.6.2.2 Removing the iRMC microSD card . . . . . . . . . . . . . 284
15.6.2.3 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 285
15.6.3 Replacing the iRMC microSD card . . . . . . . . . . . . . . . 285
15.6.3.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 285
15.6.3.2 Replacing the iRMC microSD card . . . . . . . . . . . . . . 285
15.6.3.3 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 286
15.7 System board . . . . . . . . . . . . . . . . . . . . . . . . . . 287
15.7.1 Replacing the system board . . . . . . . . . . . . . . . . . . . 287
15.7.1.1 Preliminary steps . . . . . . . . . . . . . . . . . . . . . . . 289
15.7.1.2 Removing the defective system board . . . . . . . . . . . . 290
15.7.1.3 Installing the new system board . . . . . . . . . . . . . . . 291
15.7.1.4 Concluding steps . . . . . . . . . . . . . . . . . . . . . . . 293
16 Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295
16.1 Overview cables . . . . . . . . . . . . . . . . . . . . . . . . 295
16.2 Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296
Upgrade and Maintenance Manual RX2510 M2
Contents
17 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . 305
17.1 Mechanical overview . . . . . . . . . . . . . . . . . . . . . 305
17.1.1 Server front . . . . . . . . . . . . . . . . . . . . . . . . . . . 305
17.1.2 Server rear . . . . . . . . . . . . . . . . . . . . . . . . . . . 306
17.1.3 Server interior . . . . . . . . . . . . . . . . . . . . . . . . . . 307
17.2 Connectors and indicators . . . . . . . . . . . . . . . . . . 309
17.2.1 Connectors and indicators on the system board . . . . . . . . 309
17.2.1.1 Onboard connectors . . . . . . . . . . . . . . . . . . . . . 309
17.2.1.2 Onboard indicators and controls . . . . . . . . . . . . . . 311
17.2.2 Server front . . . . . . . . . . . . . . . . . . . . . . . . . . . 314
17.2.2.1 Indicators on the front panel . . . . . . . . . . . . . . . . . 314
17.2.2.2 Indicator on the ODD . . . . . . . . . . . . . . . . . . . . 317
17.2.2.3 Indicators on the hot-plug HDD/SSD modules . . . . . . . 318
17.2.3 Server rear . . . . . . . . . . . . . . . . . . . . . . . . . . . 319
17.2.3.1 Connectors on the I/O panel . . . . . . . . . . . . . . . . 319
17.2.3.2 Indicators on the I/O panel . . . . . . . . . . . . . . . . . 320
17.2.3.3 Indicators on PSUs (slide-in units) . . . . . . . . . . . . . 324
17.3 Onboard settings . . . . . . . . . . . . . . . . . . . . . . . 325
17.4 Minimum startup configuration . . . . . . . . . . . . . . . . 326
RX2510 M2 Upgrade and Maintenance Manual 19
1 Introduction
This Upgrade and Maintenance Manual provides instructions for the following
procedures:
Upgrading the server configuration by adding optional hardware
components
Upgrading the server configuration by replacing existing hardware
components with superior ones.
Replacing defective hardware components
This manual focuses on on-site maintenance tasks. It is recommended to
prepare each service assignment following remote diagnostics procedures, as
described in the "ServerView Suite Local Service Concept (LSC)" manual (see
section "Documents you need at hand" on page 31.
VCAUTION!
The document at hand comprises procedures of a wide range of
complexity. Check the profile of qualification for technicians before
assigning tasks. Before you start, carefully read "Classification of
procedures" on page 23.
20 Upgrade and Maintenance Manual RX2510 M2
Introduction
1.1 Notational conventions
The following notational conventions are used in this manual:
Text in italics indicates commands or menu items
fixed font indicates system output
semi-bold fixed
font
indicates text to be entered by the user
"Quotation marks" indicate names of chapters and terms that are being
emphasized
Êdescribes activities that must be performed in the order
shown
[Abc] indicates keys on the keyboard
VCAUTION! Pay particular attention to texts marked with this symbol!
Failure to observe this warning may endanger your life,
destroy the system or lead to the loss of data.
Iindicates additional information, notes and tips
indicates the procedure category in terms of complexity
and qualification requirements, see "Classification of
procedures" on page 23
indicates the average task duration, see "Average task
duration" on page 26
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310
  • Page 311 311
  • Page 312 312
  • Page 313 313
  • Page 314 314
  • Page 315 315
  • Page 316 316
  • Page 317 317
  • Page 318 318
  • Page 319 319
  • Page 320 320
  • Page 321 321
  • Page 322 322
  • Page 323 323
  • Page 324 324
  • Page 325 325
  • Page 326 326
  • Page 327 327
  • Page 328 328

Fujitsu PRIMERGY RX2510 M2 User manual

Category
Servers
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI