ABB Relion 630 Series User manual

Type
User manual

This manual is also suitable for

Relion
®
630 series
Load Shedding Controller
PML630
IEC 61850 Point List Manual
Document ID: 1MRS757261
Issued: 2012-03-29
Revision: C
Product version: 1.1.2
© Copyright 2012 ABB. All rights reserved
Copyright
This document and parts thereof must not be reproduced or copied without written
permission from ABB, and the contents thereof must not be imparted to a third
party, nor used for any unauthorized purpose.
The software or hardware described in this document is furnished under a license
and may be used, copied, or disclosed only in accordance with the terms of such
license.
Trademarks
ABB and Relion are registered trademarks of the ABB Group. All other brand or
product names mentioned in this document may be trademarks or registered
trademarks of their respective holders.
Warranty
Please inquire about the terms of warranty from your nearest ABB representative.
http://www.abb.com/substationautomation
Disclaimer
The data, examples and diagrams in this manual are included solely for the concept
or product description and are not to be deemed as a statement of guaranteed
properties. All persons responsible for applying the equipment addressed in this
manual must satisfy themselves that each intended application is suitable and
acceptable, including that any applicable safety or other operational requirements
are complied with. In particular, any risks in applications where a system failure and/
or product failure would create a risk for harm to property or persons (including but
not limited to personal injuries or death) shall be the sole responsibility of the
person or entity applying the equipment, and those so responsible are hereby
requested to ensure that all measures are taken to exclude or mitigate such risks.
This document has been carefully checked by ABB but deviations cannot be
completely ruled out. In case any errors are detected, the reader is kindly requested
to notify the manufacturer. Other than under explicit contractual commitments, in
no event shall ABB be responsible or liable for any loss or damage resulting from
the use of this manual or the application of the equipment.
Conformity
This product complies with the directive of the Council of the European
Communities on the approximation of the laws of the Member States relating to
electromagnetic compatibility (EMC Directive 2004/108/EC) and concerning
electrical equipment for use within specified voltage limits (Low-voltage directive
2006/95/EC). This conformity is the result of tests conducted by ABB in
accordance with the product standards EN 50263 and EN 60255-26 for the EMC
directive, and with the product standards EN 60255-1 and EN 60255-27 for the low
voltage directive. The product is designed in accordance with the international
standards of the IEC 60255 series.
Table of contents
Section 1 Introduction.......................................................................3
This manual........................................................................................3
Intended audience..............................................................................3
Product documentation.......................................................................3
Product documentation set............................................................3
Document revision history.............................................................4
Related documentation..................................................................5
Symbols and conventions...................................................................5
Symbols.........................................................................................5
Document conventions..................................................................5
Functions, codes and symbols......................................................6
Section 2 Logical node list................................................................9
Logical nodes.....................................................................................9
Section 3 Logical node extensions.................................................11
New logical nodes............................................................................11
LSCACLS....................................................................................11
PWSACLS...................................................................................12
LSCCCLS....................................................................................13
SNWLRCLS ................................................................................13
SNWARCLS ...............................................................................14
LSCRCLS ...................................................................................15
Extended logical nodes....................................................................17
LLN0............................................................................................18
LDLLN0.......................................................................................18
LSLLN0........................................................................................18
SNWLLN0....................................................................................19
NCBDLLN0..................................................................................19
LSCLLN0.....................................................................................19
PWSLLN0....................................................................................20
LSCGAPC...................................................................................20
LSPTRC......................................................................................20
PWSGCSWI................................................................................21
PWSGMMXU...............................................................................21
PWSTCSWI.................................................................................22
PWSTMMXU...............................................................................22
NCBDCSWI.................................................................................23
NCBDMMXU...............................................................................23
LDCSWI.......................................................................................23
Table of contents
PML630 1
Point List Manual
LDMMXU.....................................................................................24
SPGGIO .....................................................................................24
DRRDRE.....................................................................................25
DPGGIO......................................................................................25
MVGGIO......................................................................................26
SPVNZBAT..................................................................................26
Section 4 Glossary.........................................................................27
Table of contents
2 PML630
Point List Manual
Section 1 Introduction
1.1 This manual
The point list manual describes the outlook and properties of the data points
specific to the IED. The manual should be used in conjunction with the
corresponding communication protocol manual.
1.2 Intended audience
This manual addresses the communication system engineer or system integrator
responsible for pre-engineering and engineering for communication setup in a
substation from an IED perspective.
The system engineer or system integrator must have a basic knowledge of
communication in protection and control systems and thorough knowledge of the
specific communication protocol.
1.3 Product documentation
1.3.1 Product documentation set
The application engineering guide provides information for IEC 61850 engineering
of the load shedding controller IED, protection and control IEDs and COM600
Station Automation device using PCM600, IET600 and SAB600. With a practical
example, the guide explains all the steps from system planning and engineering to
application functionality and IED parameterization for realizing the load shedding
functionality using the IEDs.
The commissioning manual contains instructions on how to commission the IED
with the load shedding power management functions. The manual can also be used
by system engineers and maintenance personnel for assistance during the testing
phase. The manual provides procedures for checking external circuitry and
energizing the IED, parameter setting and configuration. The manual describes the
process of testing an IED in a substation that is not in service. The chapters are
organized in chronological order in which the IED should be commissioned.
The communication protocol manual describes a communication protocol
supported by the IED. The manual concentrates on vendor-specific implementations.
1MRS757261 C Section 1
Introduction
PML630 3
Point List Manual
The engineering manual contains instructions on how to engineer the IED using
PCM600. The manual provides instructions on how to set up a PCM600 project
and insert IEDs to the project structure. The manual also recommends a sequence
for engineering of load shedding power management function, LHMI functions as
well as communication engineering for IEC 61850.
The installation manual contains instructions on how to install the IED. The
manual provides procedures for mechanical and electrical installation. The chapters
are organized in chronological order in which the IED should be installed.
The operation manual contains instructions on how to operate the IED once it has
been commissioned. The manual provides instructions for monitoring, controlling
and setting the IED.
The point list manual describes the outlook and properties of the data points
specific to the IED. The manual should be used in conjunction with the
corresponding communication protocol manual.
The technical manual contains application and functionality descriptions and lists
function blocks, logic diagrams, input and output signals, setting parameters and
technical data sorted per function. The manual can be used as a technical reference
during the engineering phase, installation and commissioning phase, and during
normal service.
See the 630 series documentation for installation and
commissioning manuals. The PML630 documentation set includes
only application engineering guide, engineering manual, IEC 61850
communication protocol manual, IEC 61850 point list manual,
operation manual and technical manual.
1.3.2 Document revision history
Document revision/date
Product version History
A/2011-05-04 1.1 First release
B/2011-11-03 1.1.1 Content updated
C/2012-03-29 1.1.2 Content updated
Download the latest documents from the ABB Web site
http://www.abb.com/substationautomation.
Section 1 1MRS757261 C
Introduction
4 PML630
Point List Manual
1.3.3 Related documentation
Name of the document Document ID
Application Engineering Guide 1MRS757394
Engineering Manual 1MRS757184
IEC 61850 Communication Protocol Manual 1MRS757260
Operation Manual 1MRS757183
Technical Manual 1MRS757256
Product series- and product-specific manuals can be downloaded from the ABB
Web site http://www.abb.com/substationautomation.
1.4 Symbols and conventions
1.4.1 Symbols
The caution icon indicates important information or warning related
to the concept discussed in the text. It might indicate the presence
of a hazard which could result in corruption of software or damage
to equipment or property.
The information icon alerts the reader of important facts and
conditions.
The tip icon indicates advice on, for example, how to design your
project or how to use a certain function.
Although warning hazards are related to personal injury, it is necessary to
understand that under certain operational conditions, operation of damaged
equipment may result in degraded process performance leading to personal injury
or death. Therefore, comply fully with all warning and caution notices.
1.4.2 Document conventions
A particular convention may not be used in this manual.
Abbreviations and acronyms in this manual are spelled out in the glossary. The
glossary also contains definitions of important terms.
Push-button navigation in the LHMI menu structure is presented by using the
push-button icons.
1MRS757261 C Section 1
Introduction
PML630 5
Point List Manual
To navigate between the options, use and .
HMI menu paths are presented in bold.
Select Main menu/Settings.
LHMI messages are shown in Courier font.
To save the changes in non-volatile memory, select Yes and press .
Parameter names are shown in italics.
The function can be enabled and disabled with the Operation setting.
The ^ character in front of an input or output signal name in the function block
symbol given for a function, indicates that the user can set an own signal name
in PCM600.
The * character after an input or output signal name in the function block
symbol given for a function, indicates that the signal must be connected to
another function block in the application configuration to achieve a valid
application configuration.
1.4.3 Functions, codes and symbols
Table 1: Functions included in PML630
Functionality IEC 61850
Control
Double point indication
DPGGIO
1)
Monitoring
Station battery supervision
SPVNZBAT
1)
Generic measured values
MVGGIO
1)
Single point indication
SPGGIO
1)
Power management
Critical circuit breaker NCBDCSWI
Contingency based fast load shed LSCACLS
Sheddable load trip LSPTRC
Busbar with sheddable load LDMMXU
Network power source PWSMMXU
Subnetwork output SNWRCLS
Disturbance recorder function
Disturbance recorder
DRRDRE
1)
Analog channels 1-10 (samples)
A1RADR
1)
Analog channel 11-20 (samples)
A2RADR
1)
Analog channel 21-30 (samples) A3RADR
Analog channel 31-40 (calc. val.) A4RADR
Binary channel 1-16 B1RBDR
Table continues on next page
Section 1 1MRS757261 C
Introduction
6 PML630
Point List Manual
Functionality IEC 61850
Binary channel 17-32 B2RBDR
Binary channel 33-48
B3RBDR
1)
Binary channel 49-64
B4RBDR
1)
1) The function is not used by default. However, it is kept enabled in the Application Configuration tool
for instantiation in any additional user defined logic other than the features offered by the IED
Connectivity Package.
1MRS757261 C Section 1
Introduction
PML630 7
Point List Manual
8
Section 2 Logical node list
2.1 Logical nodes
Table 2: Logical nodes implemented in PML630
Logical node groups Logical node Description
C: Logical nodes for control CSWI
Calculated circuit breaker status
- Critical circuit breaker related information
- Generators
- Grid transformers
- Load feeders
L: System logical nodes
LPHD Physical device information
LLN0 Logical node zero
P: Logical nodes for protection
functions PTRC Load shed trip command
G: Logical nodes for generic
references GAPC Load shedding status (start/operate)
M: Logical nodes for metering
and measurement
MMXU
Measurement:
- Critical circuit breaker related information
- Generators
- Grid transformers
- Load feeders
1MRS757261 C Section 2
Logical node list
PML630 9
Point List Manual
10
Section 3 Logical node extensions
3.1 New logical nodes
Table 3: New functions in PML630
LN Class Prefix LN Type Description
ACLS LSC LSCACLS
LN Class: 'A' for Automatic control, 'C' for Contingency
based, 'LS' for Load shedding)
LN Prefix: Contingency based Load shedding (Fast
load shedding)
ACLS PWS PWSACLS
LN Class: 'A' for Automatic control, 'C' for Contingency
based, 'LS' for Load shedding)
LN Prefix: PoWer Source (Slow load shedding for Grid
Transformers)
CCLS LSC LSCCCLS
LN Class: 'C' for Supervisory control, 'C' for
Contingency based, 'LS' for Load shedding)
LN Prefix: Load shedding (Manual) Control
RCLS SNWL SNWLRCLS
LN Class: 'R' for (Load shedding) Related (function), 'C'
for Contingency based, 'LS' for Load shedding)
LN Prefix: SubNetWork Load shed information
RCLS SNWL SNWARCLS
LN Class: 'R' for (Load shedding) Related (function), 'C'
for Contingency based, 'LS' for Load shedding)
LN Prefix: SubNetWork Accumulated load power
information
RCLS LSC LSCRCLS
LN Class: 'R' for (Load shedding) Related (function), 'C'
for Contingency based, 'LS' for Load shedding)
LN Prefix: (Substation) Load shedding controller
information summary
3.1.1 LSCACLS
Table 4: LSCACLS
Attribute name
DATA type Explanation M/O/E
ACLS class
ACLS Contingency load shedding (Fast LS) M
Data
Common Logical Node Information
Mod ABB_c_dINC Mode (Fast load shed function
Enable / Disable / Test command/
status)
M
Beh ABB_a_dINS Behaviour (Reflects the mode of the
function)
M
Health ABB_c_dINS Health M
NamPlt ABB_b_dLPL Name plate M
Table continues on next page
1MRS757261 C Section 3
Logical node extensions
PML630 11
Point List Manual
Attribute name DATA type Explanation M/O/E
OpCntRs ABB_v4_dSPC LS Operation counter (reset
command/ status)
E
Controls
Rs ABB_v4_dSPC Load shed function reset command E
SNtw1Rs ABB_v4_dSPC Subnetwork 1 reset command E
SNtw2Rs ABB_v4_dSPC Subnetwork 2 reset command E
SNtw3Rs ABB_v4_dSPC Subnetwork 3 reset command E
SNtw4Rs ABB_v4_dSPC Subnetwork 4 reset command E
Status information
Str ABB_f_dACD Load shed function Start E
Op ABB_b_dACT Load shed function Operate E
3.1.2 PWSACLS
Table 5: PWSACLS
Attribute name DATA type Explanation M/O/E
ACLS class
ACLS Contingency load shedding (Slow LS) M
Data
Common Logical Node Information
Mod ABB_c_dINC Mode (Slow load shed function
Enable / Disable / Test command/
status)
M
Beh ABB_a_dINS Behaviour (Reflects the mode of the
function)
M
Health ABB_c_dINS Health M
NamPlt ABB_b_dLPL Name plate M
Measured Values
TmElaTrf ABB_v2_dMV Elapsed time for Grid trasnformer E
TmIDMTTrf ABB_v2_dMV IDMT Time for Grid transformer E
MaxDmdS ABB_v2_dMV Maximum demand MVA limit setting E
MaxCurTrf ABB_v2_dMV Maximum current for grid transformer E
Controls
Rs ABB_v1_dSPC Load shed function reset command E
Status information
Str ABB_f_dACD Load shed function start E
Op ABB_b_dACT Load shed function operate E
TrfOvLod ABB_v1_dSPS Grid transformer overloaded E
MaxDmdExc ABB_v1_dSPS Max Demand Exceeded (Violated) E
MaxDmdTm ABB_v1_dINS Maximum demand time limit setting E
Section 3 1MRS757261 C
Logical node extensions
12 PML630
Point List Manual
3.1.3 LSCCCLS
Table 6: LSCCCLS
Attribute name DATA type Explanation M/O/E
CCLS class
CCLS
Contingency load shedding (Manual
LS) M
Data
Common Logical node information
Mod ABB_c_dINC Mode (Manual load shed function
Enable / Disable / Test command /
status)
M
Beh ABB_a_dINS Behaviour (Reflects the mode of the
function)
M
Health ABB_c_dINS Health M
NamPlt ABB_b_dLPL Name plate M
Controls
ManLSCmd ABB_v4_dSPC Subnetwork manual load shed
command
E
3.1.4 SNWLRCLS
Table 7: SNWLRCLS
Attribute name
DATA type Explanation M/O/E
RCLS class
RCLS
Contingency load shedding related -
Subnetwork information M
Data
Common Logical Node Information
Mod ABB_c_dINC Mode M
Beh ABB_a_dINS Behaviour M
Health ABB_c_dINS Health M
NamPlt ABB_b_dLPL Name plate M
Measured Values
NtwAvbPwr ABB_v2_dMV Network total available power (Sum of
power values from all generators and
grid transformers inclusive of
maximum capabilities)
E
NtwLod ABB_v2_dMV Network total load E
NtwPwrBal ABB_v2_dMV Network power balance (The spinning
reserve value of the network)
E
NtwLodInhM ABB_v2_dMV Network load inhibit by Operator (Load
value that is inhibited from being shed
by the operator)
E
Table continues on next page
1MRS757261 C Section 3
Logical node extensions
PML630 13
Point List Manual
Attribute name DATA type Explanation M/O/E
NtwLodInhS ABB_v2_dMV Network load inhibit by system (Load
value that is inhibited from being shed
by the system)
E
NtwLodMm ABB_v2_dMV Network load mismatch (Total value of
non-sheddable loads)
E
NtwShbLod ABB_v2_dMV Network sheddable load (Total value
of sheddable loads (accumulated)
E
NtwMLodShd ABB_v2_dMV Network must load shed (Load value
that must be shed (at minimum) to
establish power balance)
E
NtwALodShd ABB_v2_dMV Network actual load shed (Load value
of the calculated shed priority)
E
NtwPwrDiff ABB_v2_dMV Network power difference (The
difference of load value between
actually shed and must be shed)
E
Status information
NtwSt ABB_v1_dSPS Network status (Active /Inactive) E
LSBlkSt ABB_v1_dSPS s Load shedding block status E
SlwLSBlkSt ABB_v1_dSPS Slow load shedding block status E
NtwLSPrio ABB_v1_dINS Network actual shed priority (Priority
for load shedding calculated by the
function)
E
LSOpSt ABB_v1_dINS Fast/Slow/Manual load shed operate E
3.1.5 SNWARCLS
Table 8: SNWARCLS
Attribute name
DATA type Explanation M/O/E
RCLS class
RCLS
Contingency load shedding related -
Subnetwork accumulated load
information M
Data
Common Logical Node Information
Mod ABB_c_dINC Mode (Fast load shed function
Enable / Disable / Test command/
status)
M
Beh ABB_a_dINS Behaviour (Reflects the mode of the
function)
M
Health ABB_c_dINS Health M
NamPlt ABB_b_dLPL Name plate M
Measured value
ALodPrio1 ABB_v2_dMV Accumulated Load against Priority 1 E
ALodPrio2 ABB_v2_dMV Accumulated Load against Priority 2 E
ALodPrio3 ABB_v2_dMV Accumulated Load against Priority 3 E
Table continues on next page
Section 3 1MRS757261 C
Logical node extensions
14 PML630
Point List Manual
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

ABB Relion 630 Series User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI