Ever UPS SPECLINE AVR Pro 700 Reference guide

Category
Uninterruptible power supplies (UPSs)
Type
Reference guide
SPECLINE AVRSPECLINE AVR
STATUS
SPECLINE AVR
1
2
4
3
UPS EVER
SPECLINE AVR PRO 700
QUICK REFERENCE GUIDE
Note: to obtain detailed information, please read the full instruction manual,
which can be downloaded from our website www.ever.eu.
2. ADDITIONAL REMARKS
MODUŁ BATERYJNY
SPECLINE AVR
>10 cm >10 cm
>10 cm
>10 cm
SPECLINE AVR PRO battery back-ups are not designed to power medical equipment,
in particular life support machines!
SPECLINE AVRSPECLINE AVR
STATUS
SPECLINE AVR UPS SPECLINE AVR PRO 700
4. INSTALLATION OF THE UPS
2
1
1 – Connectors chamber
2 – Cable glands
3 – Battery module earthing point
4 – Battery module installation brackets
5 – DC fuse sockets
3
5
2
4
MODUŁ BATERYJNY
SPECLINE AVR
SPECLINE AVR BATTERY MODULE
MODUŁ BATERYJNY
SPECLINE AVR
CONNECTING THE BATTERY MODULES
- 1-3 42 Ah battery modules can be connected to the UPS. The connections should be made with section wire
- Both the module and the UPS are delivered with fuses. The DC fuses should be removed from their sockets for transportation and installation. They
should only be installed after completing all connection steps.
- A protective earthing connection should be made between the battery module and the UPS, with a yellow-green wire. The ends of the wire should
2
have M4 ring terminals for 1 mm wire.
- Mistakenly connecting an excessively high voltage or using a power source with wrong polarity may result in the need to return the UPS to the
service department.
- Special attention must be paid to the polarity of connection (the battery's plus connection with the UPS unit's plus connection, the battery's minus
connection with the UPS unit's minus connection).
2
10 mm .
3. ELEMENTS OF THE UPS AND BATTERY MODULE 1. To connect the UPS to the mains, attach the ends of the power cord to the terminals (L, N, PE) of the INPUT connector. The power cord is not included.
2. To make sure the UPS and the connected devices operate properly, the N (neutral) conductor must be continuous.
3. To connect the secured device to the UPS, connect the ends of the individual conductors to the terminals (L, N, PE) of the OUTPUT connector.
4. The power cords of the UPS and the protected device must be secured against unintended and sudden removal by attaching cable glands. The connections must
be made with 1 mm section wires. The terminals of the wires (L, N) should end with sleeves and the terminal of the PE wire should end with an M4 ring terminal for
1 mm wires.
5. The distance between the UPS and the battery modules or the car battery should be as low as possible (the recommended distance is 10 cm). This allows to use
shorter connection cables, which greatly reduces power losses in the cables.
2
2
SPECLINE AVRSPECLINE AVR
STATUS
SPECLINE AVR
max. 1,8 m
230 V
SPECLINE AVRSPECLINE AVR
STATUS
SPECLINE AVR
1. IN THE PACKAGING
UPS unit
Mounting
template
Quick
reference guide
Warranty card
DC fuse
(UNIVAL 19 mm 40 A)
Cable glands x 4
4x
2
a) insulated sleeve terminal for 1.0 mm conductor, 8 mm long
- for the power supply and output cord
2
b) M4 ring terminal for 1.0 mm conductor
- for connecting the PE IN and PE OUT wires.
2
c) M4 ring terminal for 10 mm conductor
- for connecting a battery module
4x
a
b
c
2x
2x
SPECLINE AVRSPECLINE AVR
STATUS
SPECLINE AVR
SPECLINE AVRSPECLINE AVR
STATUS
SPECLINE AVR SPECLINE AVRSPECLINE AVR
STATUS
SPECLINE AVR SPECLINE AVRSPECLINE AVR
STATUS
SPECLINE AVR
0 ÷ 40 °C
4
1 – Main switch
2 – Signaling LED
3 – Connectors chamber
4 – Cable glands
5 – DC fuse socket (battery)
6 – AC fuse socket (mains)
7 – Installation brackets
8 – SPECLINE AVR battery module earthing
point
5
6
7
8
POWER CORD
PE
NL
EN
POWER SOURCEPOWER SOURCE
UPS unit's supply (in) installation UPS unit's supply (out) installation
POWER SOURCEPOWER SOURCE
LOADLOAD
LOAD
LOAD
ININ
ININ
OUTOUT
OUTOUT
CORRECT
INCORRECT
BATTERY MODULE
ADDITIONAL BATTERY MODULES MAINS
PE
IN
PE
OUT
IN
12 V DC
BATTERY OUT
LOAD
UPS
Use the enclosed mounting template
to hang the device
xx
xx
xx
xx
MODUŁ BATERYJNY
SPECLINE AVR
SPECLINE AVRSPECLINE AVR
STATUS
SPECLINE AVR
1
2
SPECLINE AVRSPECLINE AVR
STATUS
SPECLINE AVR
MODUŁ BATERYJNY
SPECLINE AVR
1x
CAUTION: Make sure the device is off before commencing installation.
5. THE FIRST START
Use the enclosed mounting template
to hang the device
1
2
8
* The batteries will be charged after 10-48 hrs
(depending on their capacity and charge
level), which will be properly signaled by the
LED light.
10-48 h*
SPECLINE AVRSPECLINE AVR
STATUS
SPECLINE AVR
ON
LOAD
230 V
SPECLINE AVRSPECLINE AVR
STATUS
SPECLINE AVR
OFF
LOAD
230 V
SPECLINE AVRSPECLINE AVR
STATUS
SPECLINE AVR
SPECLINE AVRSPECLINE AVR
STATUS
SPECLINE AVR
1
2
Make the connection as per guidelines in
Item 4, on the manual's first page
SPECLINE AVRSPECLINE AVR
STATUS
SPECLINE AVR
x x
x x
6. CONNECTING THE BATTERY MODULES
1
2
Make the connection as per guidelines in
Item 4, on the manual's first page
SPECLINE AVRSPECLINE AVR
STATUS
SPECLINE AVR
MODUŁ BATERYJNY
SPECLINE AVR
SPECLINE AVRSPECLINE AVR
STATUS
SPECLINE AVR
MODUŁ BATERYJNY
SPECLINE AVR
OFF
LOAD
230 V
2x
1x
8
10-48 h*
SPECLINE AVRSPECLINE AVR
STATUS
SPECLINE AVR
min. 10 cm
MODUŁ BATERYJNY
SPECLINE AVR
ON
LOAD
230 V
* The batteries will be charged after 10-48 hrs (depending on their capacity
and charge level), which will be properly signaled by the LED light.
EVER Sp. z o.o.
www.ever.eu
ups@ever.eu
9. CONTACT
8. AUDIO & VISUAL SIGNALS INDICATING THE UPS UNIT'S VARIOUS OPERATING MODES
MAINS (normal) mode
No sound signal.
Green LED on.
BACK-UP (battery) mode
Intermittent signal; frequency
increases proportionally to the
level of discharging of the
batteries, until it turns into a
continuous sound.
Amber LED on.
Battery charging
No sound signal.
Green LED is pulsating
(2250 ms ON / 250 ms OFF).
Overload *
Continuous sound signal.
The LED corresponding to the
current operating mode (mains
or back-up) is on.
Short circuit in the UPS output
Quick intermittent signal.
Red LED on.
Event Sound signal Visual signal
*The overload signaling time in back-up mode is 30 seconds. Afterwards, the UPS switches to emergency mode and
signals it with a continuous sound signal and the red LED on.
2018-01-17 v1
7. REPLACING A FUSE
SPECLINE AVRSPECLINE AVR
STATUS
SPECLINE AVR
MODUŁ BATERYJNY
SPECLINE AVR
OFF
LOAD
230 V
230 V
SPECLINE AVRSPECLINE AVR
STATUS
SPECLINE AVR
MODUŁ BATERYJNY
SPECLINE AVR
ON
LOAD
230 V
230V
a) b)
c)
c) d)
  • Page 1 1
  • Page 2 2