Delfield Refrigerated Reach Ins 6000XL & Product information

Type
Product information
Diagram
DELFIELD
980 SOUTH ISABELLA ROAD, MOUNT PLEASANT, MI 48858
844-724-CARE
WWW.DELFIELD.COM
6025XL-S, 6025XL-SH
S_R1, S_R1N, S_R1S, S_RPT1, S_RPT1S, S_RRI1, S_RRT1, SSRFF1 - Solid Doors
DESCRIPTION
SIZE
C
SCALE
UNLESS OTHERWISE SPECIFIED
.X ±
.XX ±
.XXX ±
ANG. ±
BROKEN .010 MAXIMUM.
ALL PARTS TO BE DEBURRED AND EDGES
PROJECTION
THIRD ANGLE
or used for purposes other than
of The Deleld Company.
intended without the written approval
MATERIAL
and are not to be disclosed to others
PROPRIETARY TO THE DELFIELD COMPANY
The contents of this document are
PROPRIETARY
PURCH:
QA:
.03
.010
1
MFG:
DO NOT SCALE DRAWING
SIGNATURE
DRAWN:
MGC
CHECKED:
TOLERANCES
DIMENSIONS ARE IN INCHES
.1
11/11/10
DATE
ENODIS
COVINGTON, TN
LOCATION DWG. NO.
3
1 OF 1
SHEET
RE V.
Reach-in Divison
REVISIONS
INITIAL RELEASE1
REV DESCRIPTION DATE APPROVED
9294455
LINE VOLTAGE
115/60/1
SEE NAMEPLATE FOR MAXIMUM
FUSE SIZE
COMPRESSOR
TEMPERATURE
CONTROL
SENSOR
(IF USED)
LED DISPLAY
EVAP COIL
L
CABINET AIR
SENSOR
N
L1
9294455
3) UNIT SHOWN WITH COMPRESSOR
M
N
BOX
CONTROL
HEATER
DOOR FRAMEENERGY SAVER
SWITCH
RUNNING AND DOORS CLOSED
2) THIS UNIT MUST BE GROUNDED
1) USE COPPER CONDUCTORS ONLY
ENERGY SAVER
GREY
SWITCH
DOOR
BLK
HINGE
DOOR
RED
1.1,2,3 2.1,2,3 3.1,2,3
CONTROL
TEMPERATURE
4
H
BLK
2
LC
1 3
L
W
5
N
6
F
(IF USED)
LED DISPLAY
M
SWITCH
FAN
CONDENSER
BLK
STRIPES
WITH BLUE
EVAPORATOR HOUSING
MOTOR
EVAP FAN
SENSOR
CABINET AIR
W
W
EVAP COIL
SENSOR
M
LIGHT
INCANDESCENT
W
BRN
BLK
W
W
POWER BOX
SPLICE
NUT
WIRE
PLUG
BLK
FRAME HEATERS
NOTES:
11"
8
1
2
"
CONTROL
CIRCUIT
5
RELAY
COMPRESSOR
LIGHT
INCANDESCENT
1.1,2,3 2.1,2,3 3.1,2,3
P
HEATER
DEFROST
Y
BLUE
SWITCH
W
W
FAN RELAY
F
6
M
EVAPORATOR FAN
LABEL, WIRING, 1 DR, SPEC/6000XL
C
1
CONDENSOR FAN
M
RUN
WINDING
12
COMPRESSOR
MOTOR PROTECTOR
COMPRESSOR
14
WINDING
START
13
GROUND
CAPACITOR
START RELAY
10
11
START
REFRIGERATOR, ENERGY STAR
4
HEATER
RELAY
H
2/3
L ENNIS
17-MAY-2011
ADDED L-2/3 DESIGNATION & H-4 FOR HEATER TERMINAL2
3 BROWN COMPRESSOR WIRE WAS BLACK (ON DIAGRAM ONLY)
26-MAY-2011
L ENNIS
Refrigerated Reach Ins
6000XL & SPECLINE SERIES
1 of 8
WDRfgReachIn 07/15
2 of 8
WDRfgReachIn 07/15
Refrigerated Reach Ins
6025XL-G, 6025XL-GH
S_R1, S_R1N, S_R1S, S_RPT1, S_RRI1 - Glass Doors
DESCRIPTION
SIZE
C
SCALE
UNLESS OTHERWISE SPECIFIED
.X ±
.XX ±
.XXX ±
ANG. ±
BROKEN .010 MAXIMUM.
ALL PARTS TO BE DEBURRED AND EDGES
PROJECTION
THIRD ANGLE
or used for purposes other than
of The Deleld Company.
intended without the written approval
MATERIAL
and are not to be disclosed to others
PROPRIETARY TO THE DELFIELD COMPANY
The contents of this document are
PROPRIETARY
PURCH:
QA:
.03
.010
1
MFG:
DO NOT SCALE DRAWING
SIGNATURE
DRAWN:
L ENNIS
CHECKED:
TOLERANCES
DIMENSIONS ARE IN INCHES
.1
15-APR-2011
DATE
ENODIS
COVINGTON, TN
LOCATION DWG. NO.
3
1 OF 1
SHEET
RE V.
Reach-in Divison
REVISIONS
INITIAL RELEASE1
REV DESCRIPTION DATE APPROVED
9294475
LINE VOLTAGE
115/60/1
SEE NAMEPLATE FOR MAXIMUM
FUSE SIZE
COMPRESSOR
TEMPERATURE
CONTROL
SENSOR
(IF USED)
LED DISPLAY
EVAP COIL
L
CABINET AIR
SENSOR
N
L1
9294475
M
N
BOX
CONTROL
HEATER
DOOR FRAMEENERGY SAVER
SWITCH
ENERGY SAVER
GREY
BLK
1.1,2,3 2.1,2,3 3.1,2,3
CONTROL
TEMPERATURE
4
H
BLK
2
LC
1 3
L
W
5
N
6
F
(IF USED)
LED DISPLAY
STRIPES
WITH BLUE
W
W
BLK
W
W
POWER BOX
SPLICE
NUT
WIRE
PLUG
FRAME HEATERS
11"
8
1
2
"
CONTROL
CIRCUIT
5
2/3
RELAY
COMPRESSOR
1.1,2,3 2.1,2,3 3.1,2,3
P
SWITCH
W
FAN RELAY
F
6
M
EVAPORATOR FAN
LABEL,WIRING,1DR,REF,GL
C
1
CONDENSOR FAN
M
DR,SPECLINE/6000XL,ESTAR
1) USE COPPER CONDUCTORS ONLY
2) THIS UNIT MUST BE GROUNDED
RUNNING AND DOORS CLOSED
3) UNIT SHOWN WITH COMPRESSOR
NOTES:
FLUORESCENT
LAMP SWITCH
FLUORESCENT
LAMP
FLUORESCENT
LAMP BALLAST
BALLAST
FLUORESCENT LIGHT
FLUORESCENT LAMP
SWITCH
FLUORESCENT
LAMP
BLK
BLK
RED
BLUE
FLUORESCENT LAMP ASSEMBLY
BLUE
CABINET AIR
EVAP FAN
M
MOTOR
EVAP COIL
SENSOR
SENSOR
Y
W
EVAPORATOR HOUSING
W
BLK
M
BLK
COMPRESSOR
10
STAR
WINDING
WINDING
RUN
12
13
14
11
START
START RELAY
CAPACITOR
MOTOR PROTECTOR
COMPRESSOR
GROUND
W
BRN
W
CONDENSER
FAN MOTOR
L ENNIS
02-MAY-2011
NOTES:
1. STRIP-TAC ADHESIVE BACKING
2. BLACK PRINT ON WHITE PAPER
4
H
HEATER
RELAY
ADDED L-2/3 DESIGNATION & H-4 FOR HEATER TERMINAL2
17-MAY-2011
L ENNIS
26-MAY-2011
L ENNIS
BROWN COMPRESSOR WIRE WAS BLACK (ON DIAGRAM ONLY)3
3 of 8
WDRfgReachIn 07/15
Refrigerated Reach Ins
6051XL-S, 6051XL-SH
S_R2, S_R2N, S_R2S, S_R2-SL, S_R2S-SL, S_RPT2S, S_RRI2, SSRFF2 - Solid Doors
DESCRIPTION
SIZE
C
SCALE
UNLESS OTHERWISE SPECIFIED
.X ±
.XX ±
.XXX ±
ANG. ±
BROKEN .010 MAXIMUM.
ALL PARTS TO BE DEBURRED AND EDGES
PROJECTION
THIRD ANGLE
or used for purposes other than
of The Deleld Company.
intended without the written approval
MATERIAL
and are not to be disclosed to others
PROPRIETARY TO THE DELFIELD COMPANY
The contents of this document are
PROPRIETARY
PURCH:
QA:
.03
.010
1
MFG:
DO NOT SCALE DRAWING
SIGNATURE
DRAWN:
MGC
CHECKED:
TOLERANCES
DIMENSIONS ARE IN INCHES
.1
11/11/10
DATE
ENODIS
COVINGTON, TN
LOCATION DWG. NO.
3
1 OF 1
SHEET
RE V.
Reach-in Divison
REVISIONS
INITIAL RELEASE1
REV DESCRIPTION DATE APPROVED
9294454
LINE VOLTAGE
115/60/1
SEE NAMEPLATE FOR MAXIMUM
FUSE SIZE
COMPRESSOR
TEMPERATURE
CONTROL
SENSOR
(IF USED)
LED DISPLAY
EVAP COIL
L
CABINET AIR
SENSOR
N
L1
9294454
3) UNIT SHOWN WITH COMPRESSOR
M
N
BOX
CONTROL
HEATERS
DOOR FRAMEENERGY SAVER
SWITCH
RUNNING AND DOORS CLOSED
2) THIS UNIT MUST BE GROUNDED
1) USE COPPER CONDUCTORS ONLY
ENERGY SAVER
GREY
SWITCHES
DOOR
BLK
HINGE
DOOR
RED
1.1,2,3 2.1,2,3 3.1,2,3
CONTROL
TEMPERATURE
4
H
BLK
2
LC
1 3
L
W
5
N
6
F
(IF USED)
LED DISPLAY
SWITCHES
STRIPES
WITH BLUE
EVAPORATOR HOUSING
MOTOR
EVAP FAN
SENSOR
CABINET AIR
W
W
EVAP COIL
SENSOR
M
LIGHT
INCANDESCENT
W
BRN
BLK
W
W
W
POWER BOX
SPLICE
NUT
WIRE
PLUG
DOOR FRAME HEATERS
NOTES:
11"
8
1
2
"
CONTROL
CIRCUIT
5
RELAY
COMPRESSOR
LIGHT
INCANDESCENT
1.1,2,3 2.1,2,3 3.1,2,3
P
HEATER
DEFROST
Y
BLUE
SWITCH
W
W
FAN RELAY
F
6
M
EVAPORATOR FAN
LABEL,WIRING,2 DR,SPEC/6000XL,
C
1
CONDENSOR FAN
M
CONDENSER
M
BLK
FAN
BLK
COMPRESSOR
RUN
WINDING
12
14
WINDING
STAR
10
13
11
COMPRESSOR
MOTOR PROTECTOR
GROUND
CAPACITOR
START
START RELAY
REFRIGERATOR, ENERGY STAR
2/3
HEATER
RELAY
H
4
2 ADDED L-2/3 DESIGNATION & H-4 FOR HEATER TERMINAL
L ENNIS
17-MAY-2011
3 BROWN COMPRESSOR WIRE WAS BLACK (ON DIAGRAM ONLY)
26-MAY-2011
L ENNIS
4 of 8
WDRfgReachIn 07/15
Refrigerated Reach Ins
6051XL-G, 6051XL-GH
S_R2, S_R2N, S_R2S, S_R2-SL, S_R2S-SL - Glass Doors
DESCRIPTION
SIZE
C
SCALE
UNLESS OTHERWISE SPECIFIED
.X ±
.XX ±
.XXX ±
ANG. ±
BROKEN .010 MAXIMUM.
ALL PARTS TO BE DEBURRED AND EDGES
PROJECTION
THIRD ANGLE
or used for purposes other than
of The Deleld Company.
intended without the written approval
MATERIAL
and are not to be disclosed to others
PROPRIETARY TO THE DELFIELD COMPANY
The contents of this document are
PROPRIETARY
PURCH:
QA:
.03
.010
1
MFG:
DO NOT SCALE DRAWING
SIGNATURE
DRAWN:
L ENNIS
CHECKED:
TOLERANCES
DIMENSIONS ARE IN INCHES
.1
02-MAY-2011
DATE
ENODIS
COVINGTON, TN
LOCATION DWG. NO.
3
1 OF 1
SHEET
RE V.
Reach-in Divison
REVISIONS
INITIAL RELEASE1
REV DESCRIPTION DATE APPROVED
9294476
LINE VOLTAGE
115/60/1
SEE NAMEPLATE FOR MAXIMUM
FUSE SIZE
COMPRESSOR
TEMPERATURE
CONTROL
SENSOR
(IF USED)
LED DISPLAY
EVAP COIL
L
CABINET AIR
SENSOR
N
L1
9294476
M
N
HEATERS
DOOR FRAMEENERGY SAVER
SWITCH
ENERGY SAVER
GREY
1.1,2,3 2.1,2,3 3.1,2,3
CONTROL
TEMPERATURE
4
H
BLK
2
LC
1 3
L
W
5
N
6
F
(IF USED)
LED DISPLAY
STRIPES
WITH BLUE
EVAPORATOR HOUSING
MOTOR
EVAP FAN
SENSOR
CABINET AIR
W
W
EVAP COIL
SENSOR
M
BRN
BLK
W
W
W
POWER BOX
SPLICE
NUT
WIRE
PLUG
DOOR FRAME HEATERS
11"
8
1
2
"
CONTROL
CIRCUIT
5
2/3
RELAY
COMPRESSOR
1.1,2,3 2.1,2,3 3.1,2,3
BLUE
SWITCH
FAN RELAY
F
6
M
EVAPORATOR FAN
LABEL,WIRING,2DR,REF,GL
C
1
CONDENSOR FAN
M
DR,SPECLINE/6000XL,ESTAR
FLUORESCENT
LAMP SWITCHES
LAMP BALLAST
FLUORESCENT
LAMP
FLUORESCENT
FLUORESCENT
LAMP BALLAST
FLUORESCENT
LAMP
3) UNIT SHOWN WITH COMPRESSOR
RUNNING AND DOORS CLOSED
2) THIS UNIT MUST BE GROUNDED
1) USE COPPER CONDUCTORS ONLY
NOTES:
CONTROL
BOX
SWITCH
FLUORESCENT
LAMP
FLUORESCENT LAMP ASSEMBLY
BLK
BLK W
RED
FLUORESCENT LIGHT
FLUORESCENT LAMP
BALLAST
BLUE
BLK
P
FLUORESCENT
BLK
LAMP
SWITCH
W
BLK
BALLAST
FLUORESCENT LAMP
FLUORESCENT LAMP ASSEMBLY
RED
BLUE
FLUORESCENT LIGHT
W
W
W
Y
GROUND
MOTOR PROTECTOR
COMPRESSOR
COMPRESSOR
WINDING
WINDING
RUN
14
12
STAR
10
13
11
CAPACITOR
START RELAY
START
BLK
BLK
M
CONDENSER
FAN MOTOR
L ENNIS
02-MAY-2011
NOTES:
1. STRIP-TAC ADHESIVE BACKING
2. BLACK PRINT ON WHITE PAPER
17-MAY-2011
L ENNIS
ADDED HEATER RELAY TO CONTROL & L-2/3 DESIGNATION2
H
4
HEATER
RELAY
BROWN COMPRESSOR WIRE WAS BLACK (ON DIAGRAM ONLY)3
26-MAY-2011
L ENNIS
5 of 8
WDRfgReachIn 07/15
Refrigerated Reach Ins
6076XL-S, 6076XL-SH
REVISIONS
LOCATION
DIMENSIONS ARE IN INCHES
TOLERANCES
ALL PARTS TO BE DEBURRED AND EDGES
UNLESS OTHERWISE SPECIFIED
THIRD ANGLE
PROJECTION
The contents of this document are
PROPRIETARY TO THE DELFIELD COMPANY
and are not to be disclosed to others
intended without the written approval
or used for purposes other than
of The Deleld Company.
MATERIAL
PROPRIETARY
BROKEN .010 MAXIMUM.
ANG. ±
.XXX ±
.XX ±
.X ±
.010
.03
1
.1
C
DO NOT SCALE DRAWING
SCALE
SIGNATURE
PURCH:
MFG:
QA:
L ENNIS
CHECKED:
DRAWN:
05-MAY-2011
DATE
SIZE
DESCRIPTION
1
REV DESCRIPTION
RE V.
COVINGTON, TN
ENODIS
3
SHEET
OF 1 1
DWG. NO.
Reach-in Divison
DATE APPROVED
PLUG
RECEPTICAL BOX
9294477
LED DISPLAY
CONDENSOR FAN
EVAPORATOR FAN
ENERGY SAVER
DOOR
SWITCHES
SWITCH
1.1,2,3 2.1,2,3 3.1,2,3
COMPRESSOR
RELAY
CONTROL
TEMPERATURE
LED DISPLAY
(IF USED)
L
EVAP COIL
SENSOR
SENSOR
CABINET AIR
1
C
FAN RELAY
CIRCUIT
CONTROL
6
F
5
N
INCANDESCENT
DOOR FRAME
LIGHT
HEATERS
HINGE
SWITCHES
DOOR
RED
BLK
DOOR FRAME HEATERS
L
3
TEMPERATURE
CONTROL
1.1,2,3 2.1,2,3 3.1,2,3
BLK
1 2
C L
54
H N
6
F
W
W
W
(IF USED)
COMPRESSOR
M
M
M
CONTROL
BOX
P
SWITCH
ENERGY SAVER
GREY
BLUE
CABINET AIR
CONDENSER
FAN
BLK
BLK
M
GROUND
MOTOR PROTECTOR
COMPRESSOR
COMPRESSOR
WINDING
WINDING
RUN
14
12
STAR
10
13
11
CAPACITOR
START RELAY
START
EVAP FAN
WITH BLUE
STRIPES
W
W
BRN
BLK
W
M
MOTOR
EVAP COIL
SENSOR
SENSOR
Y
W
W
INCANDESCENT
LIGHT
W
EVAPORATOR HOUSING
POWER BOX
SPLICE
WIRE
NUT
LED DISPLAY
HINGE
SWITCH
DOOR
BLK
FRAME HEATERS
L
3
TEMPERATURE
CONTROL
1.1,2,3 2.1,2,3 3.1,2,3
BLK
1 2
C L
54
H N
6
F
W
W
W
(IF USED)
P
CONTROL
BOX
SWITCH
ENERGY SAVER
GREY
BLUE
CABINET AIR
12
WINDING
BLK
BLK
CONDENSER
M
FAN
GROUND
MOTOR PROTECTOR
COMPRESSOR
WINDING
COMPRESSOR
START
RUN
14
13
CAPACITOR
EVAP FAN
BLK
BRN
WITH BLUE
STRIPES
W
W
W
M
MOTOR
EVAP COIL
SENSOR
SENSOR
Y
W
INCANDESCENT
LIGHT
W
EVAPORATOR HOUSING
START RELAY
POWER BOX
SPLICE
10
11
WIRE
NUT
START
LINE VOLTAGE
115/60/1
SEE NAMEPLATE FOR MAXIMUM
FUSE SIZE
DOOR
SWITCH
ENERGY SAVER
SWITCH
INCANDESCENT
LIGHT
DOOR FRAME
HEATER
HEATER
LED DISPLAY
(IF USED)
EVAP COIL
SENSOR
SENSOR
CABINET AIR
1.1,2,3 2.1,2,3 3.1,2,3
RELAY
COMPRESSOR
1
C
CONDENSOR FAN
M
COMPRESSOR
M
FAN RELAY
6
F
CONTROL
CIRCUIT
CONTROL
TEMPERATURE
L
2/3
N
5
M
EVAPORATOR FAN
9294477
L1
N
11"
8
1
2
"
L ENNIS
02-MAY-2011
INITIAL RELEASE
LABEL,WIRING,3DR,REF,
6000XL,ESTAR
RUNNING AND DOORS CLOSED
1) USE COPPER CONDUCTORS ONLY
2) THIS UNIT MUST BE GROUNDED
3) UNIT SHOWN WITH COMPRESSOR
NOTES:
NOTES:
1. STRIP-TAC ADHESIVE BACKING
2. BLACK PRINT ON WHITE PAPER
RED
H
4
RELAY
2/3
RELAY
HEATER
4
H
L ENNIS
17-MAY-2011
2 ADDED L-2/3 DESIGNATION & H-4 FOR HEATER TERMINAL
26-MAY-2011
L ENNIS
BROWN COMPRESSOR WIRE WAS BLACK (ON DIAGRAM ONLY)3
6 of 8
WDRfgReachIn 07/15
Refrigerated Reach Ins
6076XL-G, 6076XL-GH
REVISIONS
LOCATION
DIMENSIONS ARE IN INCHES
TOLERANCES
ALL PARTS TO BE DEBURRED AND EDGES
UNLESS OTHERWISE SPECIFIED
THIRD ANGLE
PROJECTION
The contents of this document are
PROPRIETARY TO THE DELFIELD COMPANY
and are not to be disclosed to others
intended without the written approval
or used for purposes other than
of The Deleld Company.
MATERIAL
PROPRIETARY
BROKEN .010 MAXIMUM.
ANG. ±
.XXX ±
.XX ±
.X ±
.010
.03
1
.1
C
DO NOT SCALE DRAWING
SCALE
SIGNATURE
PURCH:
MFG:
QA:
L ENNIS
CHECKED:
DRAWN:
05-MAY-2011
DATE
SIZE
DESCRIPTION
1
REV DESCRIPTION
RE V.
COVINGTON, TN
ENODIS
3
SHEET
OF 1 1
DWG. NO.
Reach-in Divison
DATE APPROVED
RECEPTICAL BOX
9294478
11"
8
1
2
"
L ENNIS
02-MAY-2011
INITIAL RELEASE
LABEL,WIRING,3DR,REF,GL DR,
6000XL,ESTAR
CABINET AIR
SENSOR
SENSOR
(IF USED)
LED DISPLAY
EVAP COIL
LAMP SWITCH
FLUORESCENT
LAMP
ENERGY SAVER
FLUORESCENT
SWITCH
DOOR FRAME
FLUORESCENT
LAMP BALLAST
HEATER
M
RELAY
COMPRESSOR
1.1,2,3 2.1,2,3 3.1,2,3
1
FAN RELAY
HEATER
C
6
COMPRESSOR
CONDENSOR FAN
M
EVAPORATOR FAN
M
9294478
LINE VOLTAGE
115/60/1
SEE NAMEPLATE FOR MAXIMUM
FUSE SIZE
CONTROL
TEMPERATURE
CONTROL
CIRCUIT
L
2/3
N
5
F
L1
N
LAMP
LAMP
COMPRESSOR
DOOR FRAME
EVAPORATOR FAN
CONDENSOR FAN
LAMP BALLAST
FLUORESCENT
FLUORESCENT
FLUORESCENT
LAMP BALLAST
FLUORESCENT
SENSOR
SENSOR
EVAP COIL
CABINET AIR
LAMP SWITCHES
FLUORESCENT
SWITCH
ENERGY SAVER
COMPRESSOR
1.1,2,3 2.1,2,3 3.1,2,3
LED DISPLAY
(IF USED)
RELAY
FAN RELAY
C
1
F
6
CONTROL
CIRCUIT
TEMPERATURE
CONTROL
L
5
N
HEATERS
M
M
M
NOTES:
1. STRIP-TAC ADHESIVE BACKING
2. BLACK PRINT ON WHITE PAPER
1) USE COPPER CONDUCTORS ONLY
2) THIS UNIT MUST BE GROUNDED
NOTES:
3) UNIT SHOWN WITH COMPRESSOR
PLUG
RUNNING AND DOORS CLOSED
ENERGY SAVER
SWITCH
H
4
1.1,2,3 2.1,2,3 3.1,2,3
CONTROL
TEMPERATURE
BLK
LC
21
3
L
GREY
BOX
CONTROL
P
POWER BOX
COMPRESSOR
(IF USED)
LED DISPLAY
W
BLK
WITH BLUE
F
6
N
5
W
W
M
W
W
STRIPES
FAN
CONDENSER
BLK
RUN
WINDING
14
12
11
10
13
START
WINDING
W
BRN
BLK
W
SPLICE
GROUND
MOTOR PROTECTOR
START
CAPACITOR
COMPRESSOR
START RELAY
NUT
WIRE
EVAPORATOR HOUSING
EVAP FAN
BLUE
SENSOR
SENSOR
EVAP COIL
CABINET AIR
Y
M
MOTOR
W
WBLK
FLUORESCENT LAMP ASSEMBLY
RED
RED
LAMP
SWITCH
FLUORESCENT
BLK
BLK
W
SWITCH
LAMP
FLUORESCENT
BLK
FLUORESCENT LAMP
FLUORESCENT LIGHT
FLUORESCENT LAMP
BALLAST
BLUE
W
FLUORESCENT LIGHT
BALLAST
BLUE
P
BLK
DOOR FRAME HEATERS
BLK
GREY
1.1,2,3 2.1,2,3 3.1,2,3
ENERGY SAVER
P
CONTROL
BLK
BOX
P
FLUORESCENT
SWITCH
LAMP
BLK W
CABINET AIR
EVAP COIL
WINDING
START
14
DOOR FRAME HEATER
BLK
W
TEMPERATURE
5
31 2
CONTROL
4 6
LED DISPLAY
(IF USED)
W
BLK
CONDENSER
M
FAN
WINDING
RUN
NLC L H F
W
SWITCH
W
BLUE
SENSOR
BRN
BLK
W
BLK
10
12
STRIPES
W
WITH BLUE
SENSOR
W
W
13
MOTOR PROTECTOR
COMPRESSOR
COMPRESSOR
GROUND
START RELAY
CAPACITOR
START
11
POWER BOX
SPLICE
WIRE
NUT
BLUE
EVAPORATOR HOUSING
FLUORESCENT LAMP ASSEMBLY
Y
FLUORESCENT LIGHT
FLUORESCENT LAMP
RED
BALLAST
MOTOR
M
EVAP FAN
ADDED HEATER RELAY TO CONTROL & L-2/3 DESIGNATION2
17-MAY-2011
L ENNIS
RELAY
H
4
RELAY
HEATER
4
H
2/3
L ENNIS
26-MAY-2011
BROWN COMPRESSOR WIRE WAS BLACK (ON DIAGRAM ONLY)3
7 of 8
WDRfgReachIn 07/15
Refrigerated Reach Ins
S_RPT2, S_RRT2, S_R3, S_RRI3 - Solid Doors
LINE VOLTAGE
115/60/1
SEE NAMEPLATE FOR MAXIMUM
FUSE SIZE
COMPRESSOR
TEMPERATURE
CONTROL
SENSOR
(IF USED)
LED DISPLAY
EVAP COIL
L
CABINET AIR
SENSOR
N
L1
9294479
3) UNIT SHOWN WITH COMPRESSOR
M
N
BOX
CONTROL
HEATERS
DOOR FRAMEENERGY SAVER
SWITCH
RUNNING AND DOORS CLOSED
2) THIS UNIT MUST BE GROUNDED
1) USE COPPER CONDUCTORS ONLY
ENERGY SAVER
GREY
SWITCHES
DOOR
BLK
HINGE
DOOR
RED
1.1,2,3 2.1,2,3 3.1,2,3
CONTROL
TEMPERATURE
4
H
BLK
2
LC
1 3
L
W
5
N
6
F
SWITCHES
STRIPES
WITH BLUE
EVAPORATOR HOUSING
MOTOR
EVAP FAN
SENSOR
CABINET AIR
W
W
EVAP COIL
SENSOR
M
LIGHT
INCANDESCENT
W
BRN
BLK
W
W
W
POWER BOX
SPLICE
NUT
WIRE
PLUG
DOOR FRAME HEATERS
NOTES:
CONTROL
CIRCUIT
5
2/3
RELAY
COMPRESSOR
LIGHT
INCANDESCENT
1.1,2,3 2.1,2,3 3.1,2,3
P
Y
BLUE
SWITCH
W
W
FAN RELAY
F
6
M
HEATER
EVAPORATOR FAN
C
1
5
4
COMPRESSOR
MAIN WINDING
L
L
WINDING
MOTOR
PROTECTOR
2
N
1
S
1
2
N
START
C
R
RUN CAPACITOR
START CAPACITOR
1
2
CONDENSER
FAN MOTOR
BLK
M
BLK
M
3 HEATER ASSEMBLIES
3 DOOR UNITS EMPLOY
3 DOOR SWITCHES
3 DOOR UNITS EMPLOY
CONDENSOR FAN
M
M
(IF USED)
LED DISPLAY
3 HEATER ASSEMBLIES
3 DOOR UNITS EMPLOY
3 DOOR UNITS EMPLOY
3 LIGHT ASSEMBLIES
4
H
RELAY
POWER SWITCH
POWER SWITCH
8 of 8
WDRfgReachIn 07/15
Refrigerated Reach Ins
S_RPT2, S_RRI2, S_R3 - Glass Doors
LINE VOLTAGE
115/60/1
SEE NAMEPLATE FOR MAXIMUM
FUSE SIZE
COMPRESSOR
TEMPERATURE
CONTROL
SENSOR
(IF USED)
LED DISPLAY
EVAP COIL
L
CABINET AIR
SENSOR
N
L1
9294480
M
N
HEATERS
DOOR FRAMEENERGY SAVER
SWITCH
ENERGY SAVER
GREY
1.1,2,3 2.1,2,3 3.1,2,3
CONTROL
TEMPERATURE
4
H
BLK
2
LC
1 3
L
W
5
N
6
F
(IF USED)
LED DISPLAY
STRIPES
WITH BLUE
EVAPORATOR HOUSING
MOTOR
EVAP FAN
SENSOR
CABINET AIR
W
W
EVAP COIL
SENSOR
M
BRN
BLK
W
W
W
POWER BOX
SPLICE
NUT
WIRE
PLUG
DOOR FRAME HEATERS
CONTROL
CIRCUIT
5
2/3
RELAY
COMPRESSOR
1.1,2,3 2.1,2,3 3.1,2,3
BLUE
SWITCH
C
1
M
FLUORESCENT
LAMP SWITCHES
LAMP BALLAST
FLUORESCENT
LAMP
FLUORESCENT
FLUORESCENT
LAMP BALLAST
FLUORESCENT
LAMP
3) UNIT SHOWN WITH COMPRESSOR
RUNNING AND DOORS CLOSED
2) THIS UNIT MUST BE GROUNDED
1) USE COPPER CONDUCTORS ONLY
NOTES:
CONTROL
BOX
SWITCH
FLUORESCENT
LAMP
FLUORESCENT LAMP ASSEMBLY
BLK
BLK W
RED
FLUORESCENT LIGHT
FLUORESCENT LAMP
BALLAST
BLUE
BLK
P
FLUORESCENT
BLK
LAMP
SWITCH
W
BLK
BALLAST
FLUORESCENT LAMP
FLUORESCENT LAMP ASSEMBLY
RED
BLUE
FLUORESCENT LIGHT
W
W
W
Y
BLK
BLK
M
MOTOR
PROTECTOR
2
L
N
1
S
START CAPACITOR
COMPRESSOR
START
WINDING
2
L
N
1
C
R
4
5
RUN CAPACITOR
1
2
MAIN WINDING
M
3 DOOR UNITS EMPLOY
3 LIGHT ASSEMBLIES
3 DOOR UNITS EMPLOY
3 HEATER ASSEMBLIES
3 DOOR UNITS EMPLOY
3 LIGHT ASSEMBLIES
CONDENSOR FAN
M
CONDENSER
FAN MOTOR
3 DOOR UNITS EMPLOY
3 HEATER ASSEMBLIES
EVAPORATOR FAN
RELAY
HEATER
FAN RELAY
F
H
4
6
M
POWER SWITCH
POWER SWITCH
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Delfield Refrigerated Reach Ins 6000XL & Product information

Type
Product information

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI