  • Hello! I am an AI chatbot trained to assist you with the Extech Instruments 401014A User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
UserManual
Indoor/OutdoorTemperatureAlert
Model401014A

AdditionalUserManualTranslationsavailableatwww.extech.com
2401014AenGB_V1.02/18
Introduction
Congratulationsonyourpurchaseofthe401014AIndoor/OutdoorTemperatureAlert.This
thermometersimultaneouslydisplaysindoortemperatures(internalsensor)andoutdoor
temperatures(integratedexternalweatherproofsensor).The401014AhasaMAX/MIN
recordingutilityandauserprogrammablehighandlowalarmforoutdoortemperature
monitoring.Weshipthismeterfullytestedand
calibratedand,withproperuse,itwillprovide
yearsofreliableservice.Pleasevisitourwebsite(www.extech.com)foradditionalinformation
includingthelatestversionofthisUserManualandCustomerSupport.
Features
Large,easytoreadLCD
Indoorandoutdoortemperaturedisplays
Userprogrammablehigh/lowaudiblealarmforoutdoortemperaturemonitoring
MemoryrecordingforMAX/MINreadingswithresetbutton
Waterresistant/splashproofsensorforoutdoortemperaturemeasurements
Includestiltstand,mountingbracket,battery,and3m(9.6ft.)
thincableforeasyinstallation
ofexternalsensor
MeterDescription
FrontDescription
1. Indoortemperaturedisplay
2. Outdoortemperaturedisplay
3. MAX/MINrecordingbutton
4. ResetbuttontoclearMAX/MINreadings
BackDescription
1. Mountingbracket
2. Alarmadjustments(SETand‘+’)
3. Batterycompartmentcover
4. Tiltstand
5. Temperatureunitsselectswitch
1
2
3
4
1
2
3
4
5
3401014AenGB_V1.02/18
LCDDescription
1. Maximumdisplayicon
2. Indoortemperaturereading
3. Minimumdisplayicon
4. Outdoortemperaturereading
5. AlarmON/OFFicon
6. Outdoortemperatureunits(F/C)icon
7. Alarmsetpointprogrammingicons(uparrow
forhighalarmsetpointanddownarrowfor
lowalarmsetpoint)
8. Outdoortemperatureicon
9. Indoortemperature
units(F/C)icon
10. Indoortemperatureicon
Operation
1. Removethebatterysafetystripfromthebatterycompartmenttopowerthemeter.Seethe
Maintenancesectionforbatteryreplacementinstructions.
2. RemovetheprotectiveadhesivecoverfromtheLCDdisplay.
3. Selectthetemperatureunits(C/F)usingthetemperatureswitchonthebackofthemeter.
4. Positionthe
meterinthedesiredindoorareaandruntheexternaltemperatureprobeto
outsideareaofinterest.
5. Theupperdisplayindicatesindoortemperature.Thelowerdisplay,outdoortemperature.
MAX/MINReadings
1. Thismeterdisplaysthemaximumandminimumreadingsstoredovertime.Torecordand
viewthereadings:
a. PresstheMAX/MINbutton.Thedisplayshowsthehighestandlowestindoor
temperaturesmeasuredsincetheRESETbuttonwaslastpressed.TheMAXandMIN
iconsappearnexttotheirrespectivereadings.
b. PresstheMAX/MINbuttonagain.Thedisplayshowsthehighestandlowestoutdoor
temperaturesmeasuredsincetheRESETbuttonwaslastpressed.TheMAXandMIN
iconsappearnexttotheirrespectivereadings.
c. PresstheMAX/MINbuttonagaintoreturntonormaloperation,theMAX and MINicons
willswitchoff.
2. TocleartheMAX/MINreadings,shortpresstheRESETbuttonwhileintheMAX/MINmode.
Whenreset,theMAX/MINreadingswillshowdashesandthemeterwillbeginrecordingnew
MAX/MINreadings.YoucaneraseindoorandoutdoorMAX/MINmemoriesindependently.
1
2
3
4
5
6
7
8
9
10
4401014AenGB_V1.02/18
AudibleHigh/LowAlarm( outdoortemperatureonly)
1. LongpresstheSETbutton(backofmeter)toaccessthehighalarmsetupmode.Thelower
digitswillflashandtheuparrowiconwillappear.
2. Shortpressthe<+>buttontochangethehighalarmlimit*(longpresstoscrollfaster).
3. ShortpresstheSETbutton
toaccessthelowalarmsetupmode.Thelowerdigitswillflashand
thedownarrowiconwillappear.
4. Shortpressthe<+>buttontochangethelowalarmlimit*(longpresstoscrollfaster).
5. ShortpresstheSETbuttontoreturntothenormaloperatingmode*.
6.
Shortpressthe<+>button(backofmeter)toactivate/deactivatetheoutdoortemperature
alarm.ThealarmbelliconwillappearontheLCDwhenthealarmisactive.
7. Whenthemeasuredoutdoortemperaturereachesthehighorlowtemperaturelimit,the
buzzerwillsoundforone(1)minute.Pressthe
MAX/MINorRESETbuttontosilencethe
buzzerbeforethe1minuteintervalelapses.
8. Afteranalarmhasbeensilencedeitherbybuttonpressor1minutetimeout,youhaveto
pressthe<+>buttontoswitchoffthealarmbelliconandthenpressthe<+>buttonagainto
reenablethealarm,otherwisethealarmwillbedisabledeventhoughthealarmbelliconis
displayed.
*Notes:
Thealarmisadjustableinincrementsof1.0°Cand1.8°F.
Ifnobuttonsarepressedforapproximately7secondswhileprogrammingthehighandlow
alarmlimits,the
meterwillautomaticallyreturntothenormaloperating mode.
Maintenance
BatteryReplacement
Replacethe1.5V‘AAA’batterylocatedintherearcompartmentasexplainedbelow.
1. Opentherearbatterycompartmentbypushingthebatterycompartmentcoverdownward,
asindicatedbythearrow.
2. Removetheoldbatteryandreplacewithnewbatteryobservingcorrectpolarity.
3. Closethecompartmentcoverbeforeuse.
Safety:Pleasedisposeofbatteriesresponsibly,neverdisposeofbatteriesinafire,batteriesmay
explodeorleak.Whenstoringthemeterfor60daysormore,removethebatteryandstore
separately.
Neverdisposeofusedbatteriesorrechargeablebatteriesinhouseholdwaste.
Asconsumers,usersarelegallyrequiredtotakeusedbatteriestoappropriatecollection
sites,theretailstorewherethebatterieswerepurchased,orwhereverbatteriesaresold.
Disposal:Donotdisposeofthisinstrumentinhouseholdwaste.Theuserisobligatedtotake
endoflifedevicestoadesignatedcollectionpointforthedisposal
ofelectricalandelectronic
equipment.
5401014AenGB_V1.02/18
Cleaning
Wipethemeterhousingwithasoft,dampclothasneeded.Useamilddetergentifnecessary
butdonotusesolventsorabrasives,asthesecandamagethemeterhousinganddisplayarea.
Specifications
Display LCD,25mm(1”)digitheight
Range Indoor(internalsensor):‐10.0to60.0°C(14.0to140.0°F)
Outdoor(externalsensor):‐50.0to70.0°C(58.0to158.0°F)
Accuracy ±1.0°C(1.8°F)from0.0to50.0°C(32.0to122.0°F)
±2.0°C(3.6°F)from‐50.0to0.0°C(58.0to32.0°F)and50.0to70.0°C(122.0to
158.0°F)
Battery One(1)'AAA'1.5Vbattery
Cable Outdoortemperaturesensorcablelength:3m(9.6ft.)
Dimensions 112x102x22mm(4.4x4.0x0.9”)
Weight 186g(6.5oz.)
