Installation instructions
Glass ceramic hob Toptronic
With normal mounting frame
J039.113-3
11.10.13
1
These installation instructions apply to: 31004 (GK35TESC), 032 (GK45TEBS.1C), 039 (GK45TEBSC), 97A (GK45TESC),
977 (GK45TEASC), 31005 (GK45TERSC), 31033 (GK45TEGC)
Identification plate
The identification plate is next to the connection plate.
➤ Affix the second identification plate (enclosed) in an accessible position behind the
front of the fitted cabinet beneath the appliance.
➤ Information on the necessary mains voltage, type of current and fuse protection can be taken from the identification plate.
➤ The appliance is equipped with a mains cable that should be connected to a distribution box by the customer. For pyrometric
reasons the connection cable is not to be exchanged.
The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in the order
specified.
Application height of the appliance: up to max. 2000 m above sea level
Validity
General notes
If fitting in flammable material, the guidelines and standards for low voltage installations and for the fire protection must be
strictly observed.
This appliance is considered to be suitable for use in countries having a warm damp equable climate (WDaE). It may also be
used in other countries. If used in warm damp equable climated countries, the appliance is to be supplied through a residual
current device (RCD) having a rated residual operating current not exceeding 30 mA.
Installation accessories included
Designation Remarks Art. no.
Mounting angle right/left only with GK35TESC, GK45TESC, GK45TEBSC/.1C, GK45TEGC H6.2484
Mounting angle rear, large only with GK45TEASC H6.2221
Mounting angle front, large only with GK45TEASC H6.2408
Mounting angle right/left only with GK45TEASC H6.2409
Mounting angle front/rear only with GK45TERSC H6.3499
Wood screws for mounting angle Misc.
Accessories
Designation Art. no.
Thermal screen set
for GK35TESC, GK45TESC, GK45TEBSC/.1C, GK45TEGC
for GK45TEASC
for GK45TERSC
H6.2622
H6.2534
H6.2617
Instant adhesive for installation in stone work surfaces
Permabond F246, incl. Activator, 50 ml tube. From Silitech AG, 3008 Bern. B11.502
Set of fixing brackets for special installation cases H6.1548
Electrical connections
Electrical connections must be carried out by trained electricians in accordance with the guidelines and standards for low
voltage installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Old installations should
always be checked.
Connection plate
Identification plate
230 V~
PE/ green/yellow
N blue
L1 brown
400V 2N~
PE/ green/yellow
N blue
L1 brown
L2 black
600/550
Installation pipe
Clamp
Distribution box
400V~ 3
PE/
yellow/green
L3 grey
L2 black
L1 brown
400V~ 2
PE/
yellow/green
black
brown
L2 grey
L1