AJAX 1LT WALL MOUNT
ASSEMBLY/INSTALLATION INSTRUCTIONS
WARNING: Risk of Fire. Min 75ºC supply conductors. Consult a qualied electrician to ensure correct
installation.
Turn off the main power at the circuit breaker before installing the xture, in order to prevent possible
shock.
#519702
#519710
Customer Service 1-800-558-8700
All electrical connections must be in accordance with local and National Electrical Code (N.E.C.)
standards. If you are unfamiliar with proper electrical wiring connections obtain the services of a
qualied electrician.
Remove the xture and the mounting package from the box and make sure that no parts are missing by
referencing the illustrations on the installation instructions.
Phillips screwdriver.
1. Gently take all parts out of the package, lay them on a smooth surface, unscrew the BALL NUTS and
the FIXTURE SCREWS. Attach the CROSS BAR to the JUNCTION BOX using (2) JUNCTION BOX
SCREWS.
2. Make wire connections with WIRE NUTS:
A - Connect the black wire from Fixture to the black supply wire.
B- Connect the white wire from Fixture to the white supply wire.
C- Attach the xture ground wire to the CROSS BAR with the green GROUND SCREW. Then connect
it to the supply ground wire with a WIRE NUT. Carefully tuck wires back into the JUNCTION BOX.
3. Attach the FIXTURE to the CROSS BAR through SCREW HOLES as shown, and secure it with
BALL NUTS.
4. Attach the IRON RACK to the LAMP HOLDER and secure it with SOCKET RING.
5. Install BULB (not included). See relamping label at socket area or packaging for maximum allowed
wattage.
6. Attach the IRON RACK (01) to the IRON RACK as shown, and secure it with DECORATIVE NUTS .
CAUTION
GENERAL
TOOLS REQUIRED
ASSEMBLY AND INSTALLATION
ASSEMBLY AND INSTALLATION
(CONT.)
Please read carefully and save these instructions, as you may need them at a later date.
Turn off the power at fuse or circuit breaker.
Turn on the power at fuse or circuit breaker.
IF IN DOUBT ABOUT ELECTRICAL INSTALLATION,
CONSULT A LICENSED ELECTRICIAN.
Item # 519702 (AJAX 1LT WALL MOUNT GAL)
Item # 519710 (AJAX 1LT WALL MOUNT BRZ)
JUNCTION BOX
JUNCTION BOX SCREW
SOCKET RING
BULB (not included)
WIRE NUTS
CROSS BAR
GROUND SCREW
SCREW HOLES
BALL NUTS
LAMP HOLDER
IRON RACK
IRON RACK (01)
DECORATIVE NUTS
FIXTURE SCREWS
A
C
B
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Design House 519702 Installation guide

Category
Racks
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI