2 9х13
19 /14.4 /
/
/ 19 /14.4 /
19 /14.4 /
4-11.
- ( 1) .
-
-
-
-
.
Connect the socket outlet to the supply mains.
Wiring order
Fix doorphone units inside the Box
VIZIT
VIZIT
VIZIT
VIZIT
VIZIT
Make connections of doorphone units
Check doorphone units for proper operation.
Padlock the door
Note.
Use a 3-wire copper cable with wire cross-section no less than 0.75 mm . Before making any connections, make sure that
the supply mains power is off.
Let in the supply mains cable through the sealed mains cable inlet , .
Split the cable wires. Cut the live and neutral to the appropriate size, leaving the protective earthing wire (green / yellow) a
bit longer.
Strip the leads
Remove the cover from the socket outlet and connect the live and neutral to the socket outlet’s terminals. Restore the
cover back to its place.
Connect the protective earthing wire to the protective earthing terminal . To ensure proper connection, the wire and the
ring terminal should be clamped together with a clipper.
Fix the supply mains cable inside the Box with a cable tie
Use screws . (supplied) and holes in the back of the Box to fix doorphone units. Terminals of a control unit and power
supply units should be oriented horizontally to ensure most efficient ventilation of the units.
The Box is capable to house the following units and combinations of units:
- one control unit / power supply unit ;
- one control unit / power supply unit and one power supply unit w v EU FARADAY;
- two commutators distribution amplifiers ;
- two commutators distribution amplifiers and one power supply unit w v EU FARADAY;
- two power supply units w v EU FARADAY.
The correct location of units inside the Box is given on Figures
Let doorphone cables in through the doorphone cable inlets see Fig.
If the doorstation design provides for its earthing, connect the protective earthing wire of the doorstation to the doorstation
earthing terminal , and clamp the connection.
Plug the control unit’s / power supply unit’s mains plug in the Box socket outlet (see Fig. 4, 5).
Plug the control unit and power supply unit’s mains plugs in an adapter plug with two Euro sockets (see Fig. 6, 7, 11).
Switch the mains power on .
Switch the control unit’s power on and check doorphone units for operation following their operating instructions.
The Box is provided with a special padlock lug. Use a padlock to lock the Box.
Apadlock is not supplied.
2
.
3
8
3
6
5
7
11
10
Figure Position of control unit in the Box4 - VIZIT