  • Hello! I am an AI chatbot trained to assist you with the ACT SINGLE LINE RS485 CONVERTER User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Unit 8 IDA Business Park, Whitestown, Tallaght, Dublin 24, Ireland.
Telephone: 353 1 462 2585. Telefax: 353 1 462 2587. E-mail: [email protected] Web: www.actrl.com
Single Line RS485 Converter
Unit 8, Tallaght Business Centre, Whitestown, Tallaght, Dublin 24, Ireland.
Telephone: 353 1 462 2585. Telefax: 353 1 462 2587. E-mail: [email protected] Web: www.accesscontrol.ie
Setup for Network Operation
4 3 2 1
BAUDRATE SELECT
9600
19200
Network cable is single shielded twisted
pair: Belden 9501 or similar
ACT 2000
ACT 1000 ACT 1000
NETWORK PRINTER
Timekeeper
Lithium Battery
A
B
0V
TX
RX
Timekeeper
Lithium Battery
A
B
0V
TX
RX
RS485 line may be up to 1km in length
and connect up to 32 controllers
To next Controller
NETWORK
DOORS
SERIAL/PRINTER
DTR
RX
TX
0V
A
B
0V
Shield
120R Resistor
on last Controller.
A B 0V
NETWORK PRINTER
ACTWin Software
12V DC
Power
Supply
(300mA)
+12V
0V
1 +12V
2 0V & Shield
3 B
4 A
Pin Function
RS-485 Bus
RS-232
1. From the Controller keypad Enter Installer Menu->Communications and set a unique address
for each controller on the network. Set Direct Connect to No.
2. From ACTWin create a new database. In the database creation wizard check RS-485
Automatic Interface. This setting is also available from View->Options->Comms.
3. Connect to the controllers from ACTWin. The LED on the RS485 converter should blink
rapidly indicating communications in progress.