Identification:
Technical
Bulletin no:
Date:
Issuer:
Factory:
D06
CGX2006-18 (page 1 of 2), 2
nd
ed.
27 April 2007
R. Sartor (DWS Customer Support)
DW Vallenoncello - Italy
Subject
Start-up Switch & Thermal Protection Setting in new
RT WTM / RTC / WTC
Model
Whole Modular Rack Type (WTM series) range and Compact Rack Type
(RTC / WTC series) range with relevant Drying Tunnels.
Problem
There are different start-up switches and thermal protections to be set
according to the electrical load.
Action in
Field
Here below you find all loads and their start-up switch and thermal protection
setting when voltage supply is 400V / 3N / 50Hz:
WTM
Pump
Ebara
DWO300
Pump
Ebara
DWO150
Pump Ebara
CDX70/05
Duo Rinse
pump
LGB
ZF121SX
Rinse pump
LGB PMP45
Rinse pump
Olympia
T45
CU fan
Lafert
ST56S2
DT900 fan
Lafert
AM90L BA6
DT600 &
DT90° fan
Lafert
ST71C4
Where
used
Prewash
WTM250
WTM300
Wash
WTM140
WTM165
WTM180
WTM200
WTM250
WTM300
Prewash
WTM300
Wash
WTM165
WTM200
WTM250
WTM300
Prewash
WTM180
WTM200
All WTM All WTM All WTM
Level A
(with ESD)
Drying
Tunnel
900 mm
Drying
Tunnel
600 mm
&
Corner
Drying
Tunnel
EWD
reference
QM4 /
QM7
QM5 QM8 QM1 QM2 QM2 QM6 QM11 QM11
Thermal
protection
setting (A)
6,3 3,3 1,2 1,3 1,6 0,8 1,3 4,2 1,2
ELECTROLUX PROFESSIONAL SPA
MAILING ADDRESS TELEPHONE WEBSITE VAT NO.
VIA SEGALUZZA, 30
33170 PORDENONE - ITALY
++39 0434 380650 www.electrolux.com 00072220932
OFFICE ADDRESS TELEFAX E-MAIL ADDRESS
VIA SEGALUZZA, 30
33170 PORDENONE - ITALY
++39 0434 380643
++39 0434 385646
Share more of our thinking at www.electrolux.com