MICRO-EPSILON capaNCDT 6200 User manual

Category
Measuring, testing & control
Type
User manual
CS005
CS02
CSH02
CSH02FL
CS05
CSE05
CSE05/M8
CSH05
CSH05FL
CS08
CS1
CSE1
CSE1,25/M12
CSH1
CSH1FL
CS1HP
CSH1.2
CSH1.2FL
CSH2FL
CSH3FL
CS2
CSH2
CSE2
CSE2/M16
CS3
CSE3/M24
CS5
CS10
CSG0.50
CSG1.00
Operating Instructions
capaNCDT 6200
Non-contact Capacitive Displacement Measuring
MICRO-EPSILON
MESSTECHNIK
GmbH & Co. KG
Koenigbacher Str. 15
94496 Ortenburg / Germany
Tel. +49 (0) 8542 / 168-0
Fax +49 (0) 8542 / 168-90
www.micro-epsilon.com
capaNCDT 6200
Contents
1. Safety ........................................................................................................................................ 7
1.1 Symbols Used ................................................................................................................................................. 7
1.2 Warnings .......................................................................................................................................................... 7
1.3 Notes on CE Marking ...................................................................................................................................... 8
1.4 Intended Use ................................................................................................................................................... 9
1.5 Proper Environment ......................................................................................................................................... 9
2. Functional Principle, Technical Data .................................................................................... 10
2.1 Measuring Principle ....................................................................................................................................... 10
2.2 Structure ........................................................................................................................................................ 11
2.2.1 Sensors ......................................................................................................................................... 12
2.2.2 Sensor Cable ................................................................................................................................ 14
2.2.3 Controller ...................................................................................................................................... 15
2.3 Technical Data ............................................................................................................................................... 17
2.4 Options .......................................................................................................................................................... 18
3. Delivery .................................................................................................................................. 20
3.1 Unpacking, Included in Delivery.................................................................................................................... 20
3.2 Storage .......................................................................................................................................................... 20
4. Installation and Assembly ...................................................................................................... 21
4.1 Precautionary Measures ................................................................................................................................ 21
4.2 Sensor ............................................................................................................................................................ 21
4.2.1 Radial Point Clamping with Grub Screw, Cylindric Sensors ....................................................... 21
4.2.2 Circumferential Clamping, Cylindric Sensors .............................................................................. 22
4.2.3 Flat Sensors .................................................................................................................................. 22
4.2.4 Dimensional Drawings Sensors ................................................................................................... 23
4.3 Sensor Cable ................................................................................................................................................. 31
4.4 Controller ....................................................................................................................................................... 34
4.4.1 Basic Unit, Demodulator Module ................................................................................................. 34
4.4.2 Housing Cover .............................................................................................................................. 35
4.5 Insert Demodulator Module ........................................................................................................................... 36
4.6 Ground Connection, Earthing ....................................................................................................................... 39
capaNCDT 6200
4.7 Electrical Connections ................................................................................................................................... 40
4.7.1 Connectivity Options ................................................................................................................... 40
4.7.2 Pin Assignment Supply, Trigger ................................................................................................... 41
4.7.3 Pin Assignment Analog Output .................................................................................................... 41
4.7.4 Pin Assignment Synchronization ................................................................................................. 42
5. Operation ................................................................................................................................ 44
5.1 Starting Up ..................................................................................................................................................... 44
5.2 Operating or Display Elements ..................................................................................................................... 44
5.2.1 LED‘s ............................................................................................................................................ 44
5.2.2 Poti ................................................................................................................................................ 45
5.2.3 Change Ethernet / EtherCAT ........................................................................................................ 46
5.3 Changing Limit Frequency ............................................................................................................................ 46
5.4 Triggering ....................................................................................................................................................... 47
5.5 Measurement Averaging ............................................................................................................................... 49
5.5.1 Introduction .................................................................................................................................. 49
5.5.2 Moving Average ............................................................................................................................ 49
5.5.3 Arithmetic Average Value ............................................................................................................. 50
5.5.4 Median .......................................................................................................................................... 50
5.5.5 Dynamic Noise Rejection ............................................................................................................. 50
6. Ethernet Interface ................................................................................................................... 51
6.1 Hardware, Interface ....................................................................................................................................... 51
6.2 Data Format of Measuring Values ................................................................................................................. 55
6.3 Settings .......................................................................................................................................................... 56
6.4 Commands .................................................................................................................................................... 59
6.4.1 Data Rate (STI) ............................................................................................................................. 59
6.4.2 Trigger Mode (TRG) ...................................................................................................................... 61
6.4.3 Get Measured Data (GMD)........................................................................................................... 61
6.4.4 Filter, Averaging Type (AVT) ......................................................................................................... 62
6.4.5 Filter, Averaging Number (AVN) ................................................................................................... 62
6.4.6 Channel Status (CHS) .................................................................................................................. 63
6.4.7 Mode of Linearization (LIN) .......................................................................................................... 63
6.4.8 Set Linearization Point (SLP) ........................................................................................................ 64
6.4.9 Get Linearization Point (GLP) ....................................................................................................... 65
6.4.10 Status (STS).................................................................................................................................. 65
6.4.11 Version (VER) ............................................................................................................................... 66
6.4.12 Set Mathematic Function (SMF) ................................................................................................... 66
6.4.13 Get Mathematic Function (GMF) .................................................................................................. 68
capaNCDT 6200
6.4.14 Clear Mathematic Function (CMF) ............................................................................................... 68
6.4.15 Ethernet Settings (IPS) ................................................................................................................. 69
6.4.16 Change between Ethernet and EtherCAT (IFC = Interface) ....................................................... 69
6.4.17 Query Data Port (GDP) ................................................................................................................. 70
6.4.18 Set Data Port (SDP) ...................................................................................................................... 70
6.4.19 Access Channel Information (CHI)............................................................................................... 70
6.4.20 Access Controller Information (COI) ............................................................................................ 71
6.4.21 Login for Web Interface (LGI) ....................................................................................................... 71
6.4.22 Logout for Web Interface (LGO) ................................................................................................... 71
6.4.23 Change Password (PWD)............................................................................................................. 72
6.4.24 Change Language for the Web Interface (LNG) .......................................................................... 72
6.4.25 Write Measuring Range Information in Channel (MRA) ............................................................... 72
6.4.26 Set Analog Filter (ALP) ................................................................................................................. 73
6.4.27 Default Messages ........................................................................................................................ 73
6.5 Operation Using Ethernet .............................................................................................................................. 74
6.5.1 Requirements ............................................................................................................................... 74
6.5.2 Access via Web Interface ............................................................................................................. 76
6.5.3 Operating Menu, Set Controller Parameter ................................................................................. 76
6.6 Channel n ....................................................................................................................................................... 77
6.6.1 Channel Information, Measuring Range ...................................................................................... 77
6.6.2 Linearization ................................................................................................................................. 77
6.6.3 Math Function ............................................................................................................................... 79
6.7 Measurement Settings ................................................................................................................................... 80
6.7.1 Measurement Mode ..................................................................................................................... 80
6.7.1.1 Data Rate ..................................................................................................................... 80
6.7.1.2 Filter type / Averaging ................................................................................................. 81
6.7.1.3 Analog Low Pass Filter ................................................................................................ 81
6.7.2 Trigger Mode ................................................................................................................................ 81
6.8 System Settings ............................................................................................................................................. 82
6.8.1 Language Selection...................................................................................................................... 82
6.8.2 Login, Changing User Level ......................................................................................................... 82
6.8.3 Password ...................................................................................................................................... 83
6.8.4 Ethernet Settings .......................................................................................................................... 83
6.8.5 Import, Export ............................................................................................................................... 84
6.9 Firmware Update ........................................................................................................................................... 84
7. EtherCAT Interface ................................................................................................................. 85
7.1 Introduction .................................................................................................................................................... 85
7.2 Change Interface ........................................................................................................................................... 85
capaNCDT 6200
8. Measurement .......................................................................................................................... 86
9. Operation and Maintenance .................................................................................................. 87
10. Liability for Material Defects .................................................................................................. 88
11. Decommissioning, Disposal .................................................................................................. 88
Appendix ................................................................................................................................................ 89
A 1 Accessories, Service .............................................................................................................. 89
A 1.1 Conversion Kit ................................................................................................................................................ 89
A 1.3 PC6200-3/4 .................................................................................................................................................... 91
A 1.4 Optional Accessories ..................................................................................................................................... 91
A 1.5 Service ........................................................................................................................................................... 94
A 2 Factory Setting ....................................................................................................................... 95
A 3 Tilt Angle Influence on the Capacitive Sensor ..................................................................... 96
A 4 Measurement on Narrow Targets .......................................................................................... 97
A 5 Measurements on Balls and Shafts ...................................................................................... 98
A 6 EtherCAT Documentation ...................................................................................................... 99
A 6.1 Preamble ........................................................................................................................................................ 99
A 6.1.1 Structure of EtherCAT®-Frames .................................................................................................. 99
A 6.1.2 EtherCAT® Services ................................................................................................................... 100
A 6.1.3 Addressing and FMMUs ............................................................................................................. 101
A 6.1.4 Sync Manager ............................................................................................................................ 101
A 6.1.5 EtherCAT State Machine ............................................................................................................ 102
A 6.1.6 CANopen over EtherCAT............................................................................................................ 103
A 6.1.7 Process Data PDO Mapping ...................................................................................................... 103
A 6.1.8 Service Data SDO Service .......................................................................................................... 104
A 6.2 CoE – Object Directory ................................................................................................................................ 104
A 6.2.1 Communication Specific Standard Objects (CiA DS-301) ........................................................ 104
A 6.2.2 Manufacturer Specific Objects ................................................................................................... 107
A 6.3 Measurement Data Format .......................................................................................................................... 110
A 6.4 EtherCAT Configuration with the Beckhoff TwinCAT©-Manager ................................................................ 111
Page 7
Safety
capaNCDT 6200
1. Safety
System operation assumes knowledge of the operating instructions.
1.1 Symbols Used
The following symbols are used in these operating instructions:
Indicates a hazardous situation which, if not avoided, may result in minor or moderate
injury.
Indicates a situation that may result in property damage if not avoided.
Indicates a user action.
i
Indicates a tip for users.
Measure
Indicates hardware or a software button/menu.
1.2 Warnings
Disconnect the power supply before touching the sensor surface.
> Risk of injury
> Static discharge
Connect the power supply and the display/output device according to the safety regulations for electrical
equipment.
> Risk of injury
> Damage to or destruction of the sensor and/or controller
Avoid shocks and impacts to the sensor and controller.
> Damage to or destruction of the sensor and/or controller
The supply voltage must not exceed the specified limits.
> Damage to or destruction of the sensor and/or controller
Page 8
Safety
capaNCDT 6200
Protect the sensor cable against damage
> Destruction of the sensor
> Failure of the measuring device
1.3 Notes on CE Marking
The following apply to the capaNCDT 6200:
- EU directive 2014/30/EU
- EU directive 2011/65/EU, “RoHS“ Category 9
Products which carry the CE mark satisfy the requirements of the EU directives cited and the European
harmonized standards (EN) listed therein. The EU Declaration of Conformity is available to the responsible
authorities according to EU Directive, article 10, at:
MICRO-EPSILON Messtechnik GmbH & Co. KG
Koenigbacher Str. 15
94496 Ortenburg / Germany
The measuring system is designed for use in industrial environments and meets the requirements.
Page 9
Safety
capaNCDT 6200
1.4 Intended Use
- The capaNCDT 6200 measuring system is designed for use in industrial areas. It is used for
displacement, distance, thickness and movement measurement
position measuring of parts or machine components
- The system must only be operated within the limits specified in the technical data, see Chap. 2.3.
The system must be used in such a way that no persons are endangered or machines and other mate-
rial goods are damaged in the event of malfunction or total failure of the system.
Take additional precautions for safety and damage prevention in case of safety-related applications.
1.5 Proper Environment
- Protection class: IP 40
- Temperature range
Operation:
Sensor: -50 ... +200 °C (-58 to +392 °F)
1
Sensor cable: -100 ... +200 C (-58 to +392 °F) (CCmx and CCmx/90)
-20 ... +80 °C (-58 to +392 °F) (CCgx and CCgx/90 - permanently)
-20 ... +100 °C (-58 to +392 °F) (CCgx and CCgx/90 - 10,000 h)
Controller: +10 ... +60 °C (+50 to +140 °F)
Storage:
Sensor: -50 ... +200 °C (-58 to +392 °F)
2
Sensor cable: -50 ... +200 °C (-58 to +392 °F) (CCmx and CCmx/90)
-50 ... +80 °C (-58 to +176 °F) (CCgx and CCgx/90)
Controller: -10 ... +75 °C (+14 to +167 °F)
- Humidity: 5 - 95 % (non-condensing)
- Ambient pressure: Atmospheric pressure
- The space between the sensor surface and the target must have an unvarying dielectric constant.
- The space between the sensor surface and the target may not be contaminated (for example water,
rubbed-off parts, dust, etc.)
1) An operating temperature of -50 ... +100 °C (-58 to +212 °F) applies for the sensors CSG0.50-CA and
CSG1.00-CA -50
2) A storage temperature of -50 ... +100 °C (-58 to +212 °F) applies for the sensors CSG0.50-CA and
CSG1.00-CA -50
Page 10
Functional Principle, Technical Data
capaNCDT 6200
2. Functional Principle, Technical Data
2.1 Measuring Principle
The principle of capacitive distance measurement with the capaNCDT system is based on the principle of the
parallel plate capacitor. For conductive targets, the sensor and the target opposite form the two plate elec-
trodes.
If a constant AC current flows through the sensor capacitor, the amplitude of the AC voltage at the sensor is
proportional to the distance between the capacitor electrodes. The AC voltage is demodulated, amplified and
output as an analog signal.
The capaNCDT system evaluates the reactance X
C
of the plate capacitor which changes strictly in proportion
to the distance.
X = ; capacitance C = * *
c
1
j C
area
distance
r
o
i
A small target and bent (uneven) surfaces cause a non-linear characteristic.
This theoretical relationship is realized almost ideally in
practice by designing the sensors as guard ring capaci-
tors.
The linear characteristic of the measuring signal is
achieved for electrically conductive target materials
(metals) without any additional electronic linearization.
Slight changes in the conductivity or magnetic proper-
ties do not affect the sensitivity or linearity.
Electrical conductor
Ground
Screening electrode
Measuring electrode
Fig. 1 Functional principle of the guard ring
capacitor
Page 11
Functional Principle, Technical Data
capaNCDT 6200
2.2 Structure
The non-contact, multi-channel measuring system, installed in an aluminum housing, consists of:
- A basic module DT 6220 or DT 6230
- A demodulator module DL 6220 or DL 6230, each with integrated preamplifier per sensor
- Sensor
- Sensor cable
- Power supply cable
- Ethernet cable
- Signal output cable
The modular assembly allows to join up to 4 channels (module system).
Micro controller
Demodulator
Preamplifier
A/D
converter
Voltage
0..10 V
Current
4..20mA
Sensor
Output circuit
Analog filter
digital
switchable
Zero point
adjustable
poti
Demodulator
Preamplifier
A/D
converter
Voltage
0..10 V
Current
4..20mA
Sensor
Output circuit
Analog filter
digital
switchable
Zero point
adjustable
poti
DT 6220 / 6230 DL 6220 DL 6220
Oscillator
Voltage
conditioning
Trigger
Supply
12 ... 36 V
Ethernet
EtherCAT
Fig. 2 Block diagram capaNCDT 6200
Page 12
Functional Principle, Technical Data
capaNCDT 6200
2.2.1 Sensors
For this measurement system, several sensors can be used.
In order to obtain accurate measuring results, keep the surface of the sensor clean and free from dam-
age.
The capacitive measuring process is area-related. A minimum area (see table) is required depending on the
sensor model and measuring range. In the case of insulators the dielectric constant and the target thickness
also play an important role.
Sensors for electrical conducting targets (metals)
Sensor model Measuring range Min. target diameter
CS005 0.05 mm 3 mm
CS02 0.2 mm 5 mm
CSH02 0.2 mm 7 mm
CSH02FL 0.2 mm 7 mm
CS05 0.5 mm 7 mm
CSE05 0.5 mm 6 mm
CSE05/M6 0.5 mm 6 mm
CSH05 0.5 mm 7 mm
CSH05FL 0.5 mm 7 mm
CS08 0.8 mm 9 mm
CS1 1 mm 9 mm
CSE1 1 mm 8 mm
CSE1,25/M12 1.25 mm 10 mm
CSH1 1 mm 11 mm
CSH1FL 1 mm 11 mm
CS1HP 1 mm 9 mm
Page 13
Functional Principle, Technical Data
capaNCDT 6200
Sensor model Measuring range Min. target diameter
CSH1,2 1.2 mm 11 mm
CSH1.FL 1.2 mm 11 mm
CSH2FL 2 mm 17 mm
CS2 2 mm 17 mm
CSH2 2 mm 17 mm
CSE2 2 mm 14 mm
CSE2/M16 2 mm 14 mm
CS3 3 mm 27 mm
CSE3/M24 3 mm 20 mm
CSH3FL 3 mm 24 mm
CS5 5 mm 37 mm
CS10 10 mm 57 mm
CSG0.50 0.5 mm approx. 7 x 8 mm
CSG1.00 1.00 mm approx. 8 x 9 mm
Page 14
Functional Principle, Technical Data
capaNCDT 6200
2.2.2 Sensor Cable
Sensor and controller are connected by a special, double screened sensor cable.
Do not shorten or lengthen these special cables.
Usually, a damaged cable can not be repaired.
Switch off the device when plugging and removing connectors.
Do not crush the sensor cable.
Do not modify to the sensor cable.
> Lost of functionality
Model Cable length Cable ø 2 axial
connector
1x axial
+ 1x 90
0
For sensors Min. bending radius
once permanently
CCgxC 2/4 or 6 m 3.1 mm 0.05 - 0.8 mm
10 mm 22 mm
CCgxC/90 2/4 or 6 m 3.1 mm 0.05 - 0.8 mm
CCgxB 2/4 or 6 m 3.1 mm 1 ... 10 mm
CCgxB/90 2/4 or 6 m 3.1 mm 1 ... 10 mm
CCmxC 1.4/2.8 or 4.2 m 2.1 mm 0.05 - 0.8 mm
7 mm 15 mm
CCmxC/90 1.4/2.8 or 4.2 m 2.1 mm 0.05 - 0.8 mm
CCmxB 1.4/2.8 or 4.2 m 2.1 mm 1 ... 10 mm
CCmxB/90 1.4/2.8 or 4.2 m 2.1 mm 1 ... 10 mm
The sensors of type CSH have integrated a 1.4 long sensor cable. Cable lengths of 2.8 m are available too if
required.
Other cable lengths are also available on request.
The sensor model CSE1 (measuring range 1 mm) has the connector type C.
Page 15
Functional Principle, Technical Data
capaNCDT 6200
2.2.3 Controller
The capaNCDT 6200 Multi-channel measuring system consists of a basic module DT62xx and one up to four
demodulator modules DL62xx, according to requirements. The components are stored in aluminum hous-
ings.
Demodulator module(s)
Basic module
Demodulator module(s)
Basic module
Fig. 3 Front view basic module DT6220 with
2 demodulator modules DL6220
Fig. 4 Front view basic module DT6230 with
demodulator module DL6230 and DL6220
Basic module DT62xx
The basic module consists of the units voltage conditioning, oscillator and digital unit.
The voltage conditioning generates all required internal voltages from the supply voltage, both for the basic
module as well as the connected demodulator modules. The oscillator supplies the demodulator modules
with constant frequency and amplitude-stable alternating current. The frequency is 31 kHz. The digital unit
controls the A/D converter of the demodulator modules and measures the actual measuring values. The mea-
suring values can be read out via the Ethernet interface in digital form, see Chap. 6.
Page 16
Functional Principle, Technical Data
capaNCDT 6200
Demodulator module DL62xx
The demodulator module DL62xx consists of an internal preamplifier, demodulator, output stage and A/D
converter. The internal preamplifier generates the distance dependent measuring signal and amplifies it.
Demodulator and output stage convert the measuring signal in a standardized voltage and current signal.
The measuring values can be processed digitally with the help of the A/D converter.
The trim potentiometer zero allows a special zero adjustment of the analog output signals, see Fig. 3.
i
Output voltage can achieve up to 15 VDC, if the sensor is disconnected respectively exceedance of
measuring range.
Page 17
Functional Principle, Technical Data
capaNCDT 6200
2.3 Technical Data
Controller type DT62x0 with DL6220 DT62x0 with DL6230
Resolution static 0.004 % FSO 0.0005 % FSO
Resolution dynamic 0.02 % FSO (5 kHz) 0.005 % FSO (5 kHz)
Bandwidth 5 kHz (-3dB) 5 kHz (-3dB)
Bandwidth adjustable to 20 Hz to 20 Hz
Data rate output digital max. 3.906 kSa/s max. 3.906 kSa/s
Linearity (typical) ≤ ±0,05 % d.M. ≤ ±0,025 % d.M.
Max. sensitivity deviation ≤ ±0.1 % FSO ≤ ±0.1 % FSO
Long term stability ≤ 0.02 % FSO / month ≤ 0.02 % FSO / month
Synchronous operation supported
(multiple control units)
DT6230 only DT6230 only
Isolator measurement no no
Temperature stability 200 ppm 200 ppm
Temperature range
operation
sensor
1
-50 ... +200 °C (-58 ... +392 °F) -50 ... +200 °C (-58 ... +392 °F)
controller +10 … +60 °C (+50 ... +140 °F) +10 … +60 °C (+50 ... +140 °F)
storage -10 … +75 °C (+14 ... +167 °F) -10 … +75 °C (+14 ... +167 °F)
Supply
DT6220: 24 VDC (12 … 36 VDC)
24 VDC (15 … 36 VDC)
DT6230: 24 VDC (15 ... 36 V)
Power consumption at 24 VDC
DT6220 3.1 W (typical)
DT6230 3.8 W (typical)
per DL6220 1.8 W (typical); 2.0 W (max.)
per DL6230 1.9 W (typical); 2.2 W (max.)
Output
0 … 10 V (short-circuit proof) 0 … 10 V (short-circuit proof)
4 … 20 mA (load max. 500 Ohm) 4 … 20 mA (load max. 500 Ohm)
Ethernet Ethernet
1) A operation temperature of -50 ... +100 °C (-58 to +212 °F) applies for the sensors CSG0.50-CA and CSG1.00-CA -50
Page 18
Functional Principle, Technical Data
capaNCDT 6200
Controller type DT62x0 with DL6220 DT62x0 with DL6230
Sensors all sensors suitable all sensors suitable
Sensor cable standard CCm1.4x; CCg2.0x CCm1.4x; CCg2.0x
Sensor cable (matched)
≤ 6 m (with CCgxx) ≤ 4.2 m (with
CCmxx)
≤ 6 m (with CCgxx) ≤ 4.2 m (with
CCmxx)
Trigger TTL, 5 V
FSO = Full Scale Output
2.4 Options
Article number Designation Description
Suitable for articles
2303018
DL6220
2303022
DL6220/ECL2
2303023
DL6220/ECL3
2303029
DL6220/LC
2982044
LC DL62x0
digital
Special calibration of linearity on digital
output
2982045
LC DL62x0
analog
Special calibration on linearity on analog
output
2982046 ECL2 DL6220
Special tuning for 2 times sensor cable
length
- -
2982047 ECL3 DL6220
Special tuning for 3 times sensor cable
length
- -
2982048 EMR2 DL6220 Extended measuring range (factor: 2)
2982049 RMR1/2 DL6220 Shortened measuring range (factor: 1/2)
Page 19
Functional Principle, Technical Data
capaNCDT 6200
Article number Designation Description
Suitable for articles
2303019
DL6230
2303024
DL6230/ECL2
2303025
DL6230/ECL3
2303030
DL6230/LC
2982044
LC DL62x0
digital
Special calibration of linearity on digital
output
2982045
LC DL62x0
analog
Special calibration of linearity on analog
output
2982054 ECL2 DL6230
Special tuning for 2 times sensor cable
length
- -
2982055 ECL3 DL6230
Special tuning for 3 times sensor cable
length
- -
2982051 EMR2 DL6230 Extended measuring range (factor: 2)
2982052 EMR3 DL6230 Extended measuring range (factor: 3)
2982053 RMR1/2 DL6230 Shortened measuring range (factor: 1/2)
• Articles already contain the option
Option available
- No option available
Page 20
Delivery
capaNCDT 6200
3. Delivery
3.1 Unpacking, Included in Delivery
1 Basic module DT62x0 with 1 - 4 demodulator modules DL62x0
1 Power supply and trigger cable PC6200-3/4, 3 m long, see Chap. A 1.3
1 Ethernet cable, 3 m long
1 CD (contains instruction manual and software)
1 Conversion kit (Springs for mounting on DIN-rail, mounting plates for wall fastening, threaded rods in differ-
ent lengths), see Chap. A 1.1.
Optional accessories:
1 Sensor
1 Sensor cable with connector
Signal output cable, synchronization cable, see Chap. A 1.4
Carefully remove the components of the measuring system from the packaging and ensure that the
goods are forwarded in such a way that no damage can occur.
Check for completeness and shipping damages immediately after unpacking.
If there is damage or parts are missing, immediately contact the manufacturer or supplier.
3.2 Storage
- Temperature range storage:
Sensor: -50 ... +200 °C (-58 to +392 °F)
1
Sensor cable: -50 ... +200 °C (-58 to +392 °F) (CCmx and CCmx/90)
-50 ... +80 °C (-57 to +176 °F) (CCgx and CCgx/90)
Controller: -10 ... +75 °C (+14 to +167 °F)
- Humidity: 5 - 95 % RH (non-condensing)
1) A storage temperature of -50 ... +100 °C (-58 to +212 °F) applies for the sensors CSG0.50-CA and
CSG1.00-CA -50
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116

MICRO-EPSILON capaNCDT 6200 User manual

Category
Measuring, testing & control
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI