American Dynamics 1218 Installation And Operating Instructions Manual

Type
Installation And Operating Instructions Manual
Model 1218
Designer Series
Indoor, Light Duty Pan/Tilt
This manual describes the installation and operating procedures for the American Dynamics model 1218 Unit. The 1218 Pan/Tilt
is a high quality, light duty unit which has been specifically designed for indoor operation. The unit has been specially developed
for small CCD cameras and camera housings. It is quick and easy to install with easily adjustable limit stops. The 1218 is
available with and without presets.
Installation and Operating Instructions
The software/firmware furnished with this equipment is confidential to and is copyrighted by AMERICAN DYNAMICS. It is not
to be copied or disclosed in any manner without the express written consent of AMERICAN DYNAMICS. The
software/firmware is furnished to the purchaser under a license for use on a single system.
Information furnished by AMERICAN DYNAMICS is believed to be accurate and reliable. However, no responsibility is
assumed by AMERICAN DYNAMICS for its use; nor for any infringements of other rights of third parties which may result
from its use. No license is granted by implications or otherwise under any patent or patent rights of AMERICAN DYNAMICS.
The installation of this product should be made by qualified
service personnel and should conform to all local codes.
QA301C
Warning: This product generates, uses, and can
radiate radio frequency energy and if not
installed and used in accordance with the
instructions manual, may cause interference to
radio communications. It has been tested and
found to comply with the limits for a Class A
computing device pursuant to Part 15 of FCC
Rules, which are designed to provide reasonable
protection against such interference when
operated in a commercial environment.
Operation of this product in a residential area is
likely to cause interference in which case the
user at his own expense will be required to take
whatever measures may be required to correct
the interference.
!
WW
WW
AA
AA
RR
RR
NN
NN
II
II
NN
NN
GG
GG
To reduce the risk of fire or shock hazard, do
not expose this product to rain or moisture.
AMERICAN
DYNAMICS
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVERS (OR BACK) .
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION
!
The lightning flash with arrowhead
symbol, within an equilateral
triangle, is intended to alert the
user to the presence of uninsulated
"dangerous voltage" within the
product's enclosure that may be of
sufficient magnitude to constitute a
risk of electric shock to persons.
The exclamation point within an
equilateral triangle is intended to
alert the user to the presence of
important operating and maintenance
(servicing) instructions in the
literature accompanying the product.
UU
UU
NN
NN
PP
PP
AA
AA
CC
CC
KK
KK
II
II
NN
NN
GG
GG
AA
AA
NN
NN
DD
DD
II
II
NN
NN
SS
SS
PP
PP
EE
EE
CC
CC
TT
TT
II
II
OO
OO
NN
NN
Unpack carefully. This is an electronic product and should
be handled as such. Compare the items received with the
packing list with your order.
Be sure to save:
1. The shipping cartons and insert pieces. They are the )
safest material in which to make future shipments of
the product.
2. The IMPORTANT SAFEGUARDS sheet.
3. These Installation and Operating Instructions.
MM
MM
AA
AA
II
II
NN
NN
TT
TT
EE
EE
NN
NN
AA
AA
NN
NN
CC
CC
EE
EE
User maintenance of this unit is limited to external cleaning
and inspection. For specific recommendations refer to the
IMPORTANT SAFEGUARDS sheet packaged with this product.
II
II
NN
NN
SS
SS
TT
TT
AA
AA
LL
LL
LL
LL
AA
AA
TT
TT
II
II
OO
OO
NN
NN
AA
AA
NN
NN
DD
DD
SS
SS
EE
EE
RR
RR
VV
VV
II
II
CC
CC
EE
EE
If you require information during installation of this
product or if service seems necessary, contact the
American Dynamics Repair and Service Department at
(800) 442-2225. You must obtain a Return Authorization
Number and shipping instructions before returning any
product for service.
Do not attempt to service this product yourself. Opening or
removing covers may expose you to dangerous voltages or
other hazards. Refer all servicing to qualified personnel.
Table of Contents
Description............................................................... 1
Installation................................................................ 1
Mounting.................................................................. 2
Ceiling Mounting........................................... 2
Wall Mounting............................................... 2
Connections, Adjustments........................................ 3
Connecting the Pan/Tilt ................................. 3
Adjusting Angles of Movement..................... 3
Dimensions............................................................... 4
Specifications........................................................... back page
MOUNTING
The 1218 Pan unit can be wall or ceiling mounted.
Mounting the Unit from the Ceiling
The 1218 is supplied with a ceiling mount (see Figure 2)
adapter plate bolted to the base. The base has four holes which
accept 6 mm bolts on a 4-inch (101.6 mm) diameter. The unit
can be attached directly to the ceiling by bolting or screwing
through these holes.
Wall Mounting Using the 1391 Mount
Mount the head on a 1391 mount in the following way:
Three heavy duty screws are recommended for securing the
bracket.
Bolt the 1218 unit to the bracket using the three 6 mm bolts
and washers supplied as shown in Figure 3. The ceiling
adapter plate is not used when mounting the head to a wall
bracket.
Note: If the unit is mounted upside down, reposition the
platform through 180°. Remember that the directions
of pan and tilt are reversed.
MOUNTING
Figure 3 - Attaching 1218 Pan/Tilt to the 1391 Wall mount
2
Four holes to fit 6 mm bolts
on 4" (101.6 mm) PCD
Three holes to fit 6 mm bolts
on 1.97" (50 mm) PCD
Figure 2 - Attaching 1218 Pan/Tilt to Ceiling mount
CONNECTING THE UNIT
The 1218 Series indoor pan/tilt unit has a cable approximately
1.5 m in length which connect to a controller with 16/0.2 cable
rated at 240V. Leave enough slack on the cable to prevent
straining the cable when the head is panning. Figure 3 shows
the standard wiring color scheme for the 1218.
ADJUSTING THE ANGLES OF MOVEMENT
Adjusting the Pan Axis Angle of Movement
Make sure the 1218 is disconnected from the control
source.
The Pan Axes Limit Contact Arms are accessible from the
underside of the 1218 (see Figure 5).
Loosen the Pan Limit Switch Contact Arms with a 4 mm
Allen wrench.
Rotate the arms until the desired pan range is achieved.
Re-tighten the Contact Arm set-screws and test the 1218 for
correct pan operation.
Adjusting the Tilt Axis Angle of Movement
Make sure the 1218 is disconnected from the control
source.
Remove the plastic cover from the rear of the main body to
expose the Limit Switch Contact Arms (see Figure 6).
Using a flat-faced screw-driver, turn the lock-down screw
counter-clockwise slightly until the limit striker arms begin
to loosen.
Rotate the Contact Arms until the desired tilt angle is
achieved.
Re-tighten the lock-down screw and test the 1218 for
correct tilt operation.
RED - Pan Right
BLK - Pan Return
VIO - Tilt Up
WHT - Tilt Return
YEL - Tilt Wiper
GRN - Pan Wiper
BRN - Pot Supply
BLU - Pot Supply
Figure 4 - 1218 Wiring Connections
Tilt Limit Switch
Contact Arms
Figure 6 - Adjusting Tilt Axis Angle of Movement
Pan Limit Switch
Contact Arms
Pan Limt Switch
Rocker Arm
Figure 5 - Adjusting Pan Axis Angle of Movement
CONNECTIONS, ADJUSTMENTS
3
IF YOU ENCOUNTER ANY PROBLEMS OPERATING
THIS UNIT, OR NEED ASSISTANCE, CALL OUR
TECHNICAL SUPPORT CENTER AT:
within the United States: 1-800-442-2225
outside the United States: (914) 624-7640
2.5625"
(65.09 mm)
3.94" (100 mm)
2.75"
(69.85 mm)
5.563"
(141.3 mm)
2.75"
(69.85 mm)
5.625"
(142.88 mm)
.375" (9.53 mm)
DIMENSIONS
4
Figure 7 - 1218 Dimensions
SPECIFICATIONS
MECHANICAL
Weight Class: Light Duty
Maximum Load: 11 lbs. (5 Kg)
Pan:
Speed: 0-60°/sec.
Range: 360°
Tilt:
Speed: 0-5.0°sec.
Range: ± 25° from horizontal
Backlash: Less than 0.25%
Construction: Die-cast aluminum
Finish: Light beige powder coat enamel
Weight of Unit: 4.5 lbs. (2.0 Kg)
Overall Dimensions: 5.7"H x 4.9" W x 4.7" D
(144 mm H x 125 W mm x 120 mm D)
ELECTRICAL
Power requirements: 0-12VDC @ 50/60 Hz
Pan Operating Current: 250mA
Tilt Operating Current: 250mA
Limit Control: Adjustable, microswitch
ENVIRONMENTAL
Operating Environment: Indoor
Operating Temperature: +14°F to +140°F (-10°C to +60°C)
MODELS
AD1218//12 DC 12 VDC operation with no presets
AD1218/12DCP Same as AD1218/12DC with factory installed feedback potentiometers. Provides pan and tilt
position feedback for control by equipment having the same feature.
SPECIFICATIONS
An American Dynamics Product
Designed and built by
Sensormatic CCTV Systems Division
One Blue Hill Plaza
Pearl River, New York, 10965
(914) 624-7600
Technical Support Center: 800-442-2225
FAX: (914) 624-7685
OP1218B November 1993
Printed in USA
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

American Dynamics 1218 Installation And Operating Instructions Manual

Type
Installation And Operating Instructions Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI