QED111

SDC QED111 User manual

  • Hello! I've analyzed the provided installation instructions for the SDC LR100K2K-EM Electric Latch Retraction Device Kit, compatible with models QED111, QED114, and QED124. The document details the steps for retrofitting and wiring the device, including crucial alignment for vertical rod applications. I'm ready to address your questions about the installation process or specific details of the kit.
  • What is the purpose of this document?
    What should I do before retro-fitting an electric latch assembly into a vertical device?
    What is the electrical data for the device?
LR100K2K-EM
ELECTRIC LATCH RETRACTION DEVICE KIT
MODELS: QED111, QED114 & QED124
P:\INST INSTRUCTIONS\ELR KITS\INST-LR100K2K-EM REV D 08-22 Page 1
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email engineer@sdcsecurity.com
Carefully slide the assembly back out until the linkage JUST makes contact with the latch retraction rod. Tighten set
screws.
ELECTRICAL DATA
24VDC @ 700/200mA
RED (+) BLK (-)
PATENT #8,851,530
SET
SCREWS
TIGHTEN SET
SCREWS TO
LOCK DEVICE
IN POSITION
Short
Long
Remove and discard dogging from device. Slide the Electric Latch Retraction assembly into device and attach the
linkage to the latch retraction rod (short linkage for standard, long linkage for 4' device).
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: [email protected] ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
INSTALLATION INSTRUCTIONS
Retrofit Installation Note: 42" or 48" exit devices that have been modified to fit a 36" or smaller opening, may not have
the required space to fit the standard E. L. R. assembly. Always verify the distance from the end of the touchpad to the
end rail, and if necessary, consult with the factory for appropriate selection.
NOTE Retro-Fitting Vertical Rod Devices:
Before retro-fitting an electric latch assembly into a vertical device, the following must be done to ensure proper
alignment. Disconnect the vertical rods from the device. Install the electric latch assembly as shown above. Once the
ELR is properly installed energize it so that the push pad is dogged down, by doing so it will allow for proper alignment
for the vertical rods. Finally reconnect the vertical rods to the device and make the proper adjusments.
P:\INST INSTRUCTIONS\ELR KITS\INST-LR100K2K-EM REV D 08-22 Page 2
SECURITY DOOR CONTROLS ■ WWW.SDCSECURITY.COM
[t] 800.413.8783 ■ 805.494.0622 ■ E-mail: [email protected] ■ 801 Avenida Acaso, Camarillo, CA 93012 ■ PO Box 3670, Camarillo, CA 93011
+-
24vdc
ACCESS
CONTROL
BOARD PLACEMENT IN
POWER SUPPLY BOX
SDC 600 SERIES
POWER SUPPLY
Latch
Retraction
Module
Pigtail
8 COND
18-22AWG
JACKETED CABLE
100' MAX
BLK
WHT
GRN
ORG
RED
BLU
BRN
YEL
Match colors with provided pigtail