ABB InLine II ZHBM-ITS Series Operating instructions

Type
Operating instructions
Fuse Switch Disconnector
InLine II ZHBM-ITS
Fuse Switch Disconnector
InLine II ZHBM-ITS rev. A / 1SEP622739P0001
INSTALLATION INSTRUCTION
Tableofcontents
1
FUSE SWITCH DISCONNECTOR, InLine II ZHBM-ITS2.1
Useofsymbols
Hazardous voltage
Warnsaboutasituationwhereahazardous
voltagemaycausephysicalinjurytoa
personordamagetoequipment.
General warning
Warnsaboutasituationwheresomething
otherthanelectricalequipmentmaycause
physicalinjurytoapersonordamageto
equipment.
Caution
Provides important information or warns
aboutasituationthatmayhaveadetrimental
effectonequipment.
Information
Provides important information about the
equipment.
Receiving,handlingandstorage
2
FUSE SWITCH DISCONNECTOR, InLine II ZHBM-ITS2.1
Receiving and handling
Uponreceipt,carefullyinspecttheswitch
fordamagethatmayhaveoccurredduring
transit.Ifdamageisevident,orthereisvisible
indication of rough handling,immediately
fileadamageclaimwiththetransportation
company,andnotifyyourlocalABB salesoffice.
Donotremovetheshippingpackageuntil
the ITS2.1 module is ready to be installed.
Storage
Iftheunitwillnotbeplacedintoservice
immediately,storethedeviceinitsoriginal
packageinaclean,drylocation.Toprevent
condensation,maintainauniformtemperature.
Storetheunitinaheatedbuilding,allowing
adequate air circulation and protection
fromdirtandmoisture.Storingthe unit
outdoors couldcauseharmfulcondensation
inside the package .
HAZARD OF Overturning
Whenmovingwithaforklift,donotremove
theshippingpackageuntilthedevice
isinitsfinallocation.
Failuretofollowthisinstructionwillresult
inpersonalinjuryorequipmentdamage.
Warning
equipment
Readthesesafetyinstructions
carefullybeforeusingthisproduct!
3
FUSE SWITCH DISCONNECTOR, InLine II ZHBM-ITS2.1
HAZARDOFELECTRICSHOCK,
EXPLOSION,ORARCFLASH
Apply appropriate personal protective
equipmentandfollowsafeelectricalwork
practices.
Thisequipmentmustonlybeinstalled
andservicedbyqualifiedelectrical
personnel.
Before performing visual inspections,
tests,ormaintenanceontheequipment,
disconnectallsourcesofelectricpower.
Assumethatallcircuitsareliveunless
theyarecompletelydeenergized,tested,
grounded,andtagged.Payparticular
attentiontothedesignofthepower
system.Considerallsourcesofpower,
including the possibility of backfeeding.
Turnoffswitchbeforeremovingor
making load side connections.
Alwaysuseaproperlyratedvoltage
sensingdeviceatalllineandloadtoconfirm
switchisoff.
Turnoffpowersupplyingswitchbefore
doinganyotherworkonorinsideswitch.
Failuretofollowtheseinstructionscould
resultindeathorseriousinjury.
Danger
Busbar overview
FUSE SWITCH DISCONNECTOR, InLine II ZHBM-ITS2.1
185
100
185
100
ZHBM00-ITS
ZHBM123-ITS
4
FUSE SWITCH DISCONNECTOR, InLine II ZHBM-ITS2.1
5
FUSE SWITCH DISCONNECTOR, InLine II ZHBM-ITS2.1
ZHBM123-ITS
ZHBM00-ITS
1
3
2
1 Withdraw the connectors
Disassembling the ITS
A
B
B
2 Pull out the ITS
FUSE SWITCH DISCONNECTOR, InLine II ZHBM-ITS2.1
6
FUSE SWITCH DISCONNECTOR, InLine II ZHBM-ITS2.1
A
B
TCP Module
FUSE SWITCH DISCONNECTOR, InLine II ZHBM-ITS2.1
7
TCP Module
FUSE SWITCH DISCONNECTOR, InLine II ZHBM-ITS2.1
8
CLICK
!
TCP Module
FUSE SWITCH DISCONNECTOR, InLine II ZHBM-ITS2.1
ZHBM00-ITS
9
Busbar mounting
M8
10Nm
FUSE SWITCH DISCONNECTOR, InLine II ZHBM-ITS2.1
ZHBM123-ITS
10
Busbar mounting
M12
25Nm
Assembling the ITS
FUSE SWITCH DISCONNECTOR, InLine II ZHBM-ITS2.1
ZHBM00-ITS ZHBM123-ITS
1
3
2
1 Plug in the connectors
2 Push in the ITS
CLICK!
11
FUSE SWITCH DISCONNECTOR, InLine II ZHBM-ITS2.1
48,5
809,5
655
( )154,5
213
152,5
6
3,5
3,5
5
788
100185185
99
809,5
655
(
)
154,5
218
3,5
6
788
5
3,5
152,5
100
185
185
100
CZ
ZHBM00-ITS
ZHBM123-ITS
12
Contactus
ABB Oy
Smart Power
P.O. Box 622
FI-65101 Vaasa
Finland
© Copyright 2020 ABB. All rights reserved.
Specifications subject to change without notice.
InLine II ZHBM-ITS rev. A / 1SEP622739P0001 # 05.20.2020
> Low Voltage Products and Systems
https://new.abb.com/contact-centers
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

ABB InLine II ZHBM-ITS Series Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI