Escea EW5000 Outdoor Wood Cooking Fireplace User manual

Category
Fireplaces
Type
User manual
630211_4 EW5000 Builders and Architects Sheet630472_4 EK1550 Builders and Architects Sheet
EW5000 Information Sheet for Builders and Architects
Suitable for outdoors only.
Wood burning barbeque and outdoor fire.
For further information or specifications, visit the
technical section of our website www.escea.com to
view the latest product Installation Manual.
Appliance Information
892mm
901mm
134mm
996mm
548mm
Flue:
250mm OD
884mm Opening Width
479 mm Opening Height
426mm
122mm
377mm
504mm
758mm
64mm
600mm
35mm MIN 35mm MIN
500mm 1900mm
50mm MIN
Timber Framing
500mm 600mm 1900mm
50mm MIN
35mm MIN
B
Timber Framing
Appliance Opening
35mm MIN 35mm MIN
35mm MIN
DETAIL B
SCALE 1 : 8
AAC Heat Cell
Appliance
FRONT VIEW
TOP VIEW
SIDE VIEW
760mm
1000mm- 1230mm
490mm
760mm
490- 540mm
1000- 1230mm
WITH FASCIA WITHOUT FASCIA
900mm
570mm-- 610mm
351mm
139mm
510mm
Cavity Construction
NOTE: For Concrete or Concrete Block Structure Height dimension depending on the installation method, please see
the Installation Manual for details.
Specifications
Appliance Dimensions(mm) 996W x 758H x 548D
Appliance Weight 90.3kg
Concrete or Concrete Block Structure
Minimum Internal Cavity Dimensions (mm): 1077W x 835D
Timber or Combustible Structure
Minimum AAC Heat Cell Dimensions (mm): 1200W x 950H x 735D
Minimum Cavity Dimensions (mm): 1270W x 1550H x 770D
Minimum Requirements of Concrete | Concrete Block
Structure
This appliance is designed for outdoor use ONLY.
The firebox and the flue system can be installed into a
remote, free-standing, fully non-combustible fireplace
construction on all surfaces surrounding the fireplace and
flue. Example materials that can be used include: solid
concrete, concrete/masonry blocks, bricks, or Hebel
blocks/panels. Do not use timber framing.
For installations with a fascia, the position of the firebox
must be located so that the appliance base is flush with
the front face of the concrete structure. This is to allow
the fascia to engage into the fascia brackets. Use the
provided holes in the base to fix the firebox firmly down.
Depending on material choice, some heat may be con-
ducted through the surrounding cavity and consequently
no combustible materials should come into contact with
these hot surfaces. This is completely dependant on the
chosen material and design of installation. The user should
satisfy themselves that the installation is fit for purpose
and complies with all local and national codes.
Minimum Requirements of the Timber | Combustible
Structure
This appliance is designed for outdoor use ONLY.
It can also be installed within a free-standing timber/
combustible cavity. The cavity structure must be free-
standing and must not be connected to the envelope of
a building. However, the cavity can penetrate through a
combustible roof structure. The roof structure may be
attached to a building.
For this scenario, the appliance must be enclosed within
an Autoclaved Aerated Concrete (AAC) heat cell with
a minimum thickness of 75mm thick panels having a
thermal resistance/ R-value of no less than 0.59m2
K/W. Additionally, the appliance must be installed with
the EW Heat Cell Dropbox.
This scenario must be supplied with the triple skinned
EW5000 Timber Cavity Flue Kit. The appliance must
be frameless for this install scenario as the optional
fascia is not compatible with this installation type.
Any cladding over the front of the structure (not in-
cluding the chimney chase structure) must consist of a
heat resistant material. Cladding over any other surface
of the structure can consist of a combustible material
(eg. plywood).
Corner installation
901mm
35
1
2
"
936mm
36
7
8
"
1000mm
39 .
3
8
"
1870mm
73 .
5
8
"
490mm
19 .
5
19
"
630472_4 EK1550 Builders and Architects Sheet
The venting and sealing requirements must comply with the Installation Manual relevant section D1 and D2 on
page 11 or section E2 and E3 on page 16, depending on the installation method of choice.
Flue Specifications for the Concrete | Concrete Block Structure
Venting & Sealing Requirements
Flue Specifications for the Timber | Combustible Structure
NOTE: The appliance & flue system shall be installed in accordance with AS/NZS 2918 and these specifications.
NOTE: The flashing requirements must comply with the Installation Manual relevant section D3 on page 12 or
E4 on page 21, depending on the installation method of choice.
External Clearances to Combustible Surfaces
The cavity structure must comply with the minimum requirements as stated on the previous page depending on the
installation method of choice.
Flue Information
Clearances
Appliance opening
Appliance opening
Heat-sensitive material sidewall
650mm min
1400mm min
2000mm min
Any heat-sensitive material
Any heat sensitive roofing/ ceiling material
Floor must be non-combustible
SIDE VIEW
TOP VIEW
3.2m min (excluding cowl)
500mm
min
Gather Top
Dropbox
Flue terminal (supplied with flue kit)
Cone 250mm to 650mm (supplied with flue kit)
Spider 250-350-450-550-650mm (supplied with flue kit
)
Flashing plate with 550mm liner (installation dependent,
not supplied) - flashing must comply with relevant building
code
250-350mm spacers and 350-450mm spacers - x1
per 1200mm flue length (x3 of each supplied with flue
kit)
250mm flue (3x 1200mm lengths supplied with flue
kit)- minimum 3200mm install flue length
350mm inner liner (3x 1200mm lengths supplied with
flue kit)
450mm outer liner (3x 1200mm lengths supplied with
flue kit)
250mm spacer - transfers weight of liners back to flue
(supplied with flue kit)
AAC heat cell dropbox- MUST be installed to comply
with AS/NZS 2918 (supplied separately)
Gather Top
Timber framing chase structure (50mm clearance
required to outer liner)
Gather
Top
Entire cavity concrete/ concrete block
Flue terminal (supplied with flue kit)
Cone 250mm to 550mm (supplied
with flue kit)
Spider 250mm to 550mm (supplied
with flue kit).
Flashing liner 450mm (installation
dependent, not supplied)- flashing must
comply with relevant building code
Supported heat resistant chimney cap
with 450mm spigot (installation
dependent, not supplied)
Flue liner 350mm (2x supplied with
flue kit)
Flue 250mm (2x supplied with
flue kit)
Gather
Top
250mm spacer - transfers
weight of liner back to flue
(supplied with flue kit)
  • Page 1 1
  • Page 2 2