Anti-Skim Card Reader
Upgrade Manual
TDN 07103-00273 Rev. A
Corporate Headquarters:
21405 B Street
Long Beach, MS 39560
Phone: (800) 259-6672
Fax: (228) 868-9445
COPYRIGHT NOTICE
© 2016 Triton. All Rights Reserved. TRITON logo is a registered
trademark of Triton Systems of Delaware, LLC
Document Updates
June 9, 2016......................Rev. A..................Original 1031018
Table of Contents
EMV Anti-Skim card Reader Kits .......................................................................................................................ii
Section 1 - ARGO 7.................................................................................................................................................1-1
Section 2 - ARGO 12...............................................................................................................................................2-1
Section 3 - ARGO 15...............................................................................................................................................3-1
Section 4 - RL16XX.................................................................................................................................................4-1
Section 5 - RL23XX.................................................................................................................................................5-1
Section 6 - RL53XX.................................................................................................................................................6-1
ALL ABOVE UNITS
Section 7 - Upgrade From ICM 330 Card Reader..............................................................................................7-1
ALL ABOVE UNITS
Section 8 - Calibration and Diagnostics..............................................................................................................8-1
i
WARNING:
When the new Anti-Skim card Reader is installed, be sure to use the screws pro-
vided in the kit. DO NOT reuse the screws from the old card reader; this will
cause damage to the metal inserts on the new card reader.
e new Anti-Skim Card reader will need to be calibrated a er it is installed. Be
sure to refer to the Con guration and Diagnostics section.
Minimum so ware requirement to support the ICM33B Anti-Skim Card Reader
is 4.0.0.33
Improper grounding may
cause damage to ATM
and/or components.
*Please contact Sales@Triton.com for model availability.
Kit
06200-00355
Anti-Skim EMV Card Reader Upgrade kit for, RL16, RL23, RL53, and ARGO. Not for use
when upgrading from 330.
Tools Required Small Phillips head Screwdriver, Side Cut Pliers
Parts Supplied
Description Quantity
1 Card Reader w/Bezel | EMV | ICM33B Anti-Skim 1
2 Serial Card Reader Comms Ribbon Cable | X2 1
3 Screw | 6-32 Phillips Machine Screw | Pan Head | 3/8” long | Zinc Plated with Nylon Patch 5
4 Mounting bracket, angled, one 6-32 threaded hole, one 0.165” open hole, 0.062” thick
steel, tin plate
1
5 Screw | #6-32 | 1/4 Inch | Pan Phil Head w/Ext Tooth Wash 1
6 Triton EMV Kernel Label 1
7 Screw | #8-32 | 3/8 inch | Pan Phil Head w/Ext Tooth Wash 1
1
2
3
4
5
6
ii
7
Kit
06200-00358
Anti-Skim EMV Card Reader Upgrade kit. For upgrading from 330 only. ARGO, RL16,
RL23, RL53.
Tools Required Small Phillips head Screwdriver
Parts Supplied
Description Quantity
1 Card Reader w/Bezel | EMV | ICM33B Anti-Skim 1
2 Screw | 6-32 Phillips Machine Screw | Pan Head | 3/8” long | Zinc Plated with Nylon Patch 5
1
2
iii
SECTION 1
ANTI-SKIM CARD READER
UPGRADE
ARGO 7
KIT 06200-00355
ARGO 7
1-2
1. Carefully remove the plastic cover from the main board.
2. Unplug the Card Reader Communication Cable from the main board. Remove the cable from the cable clips.
ARGO 7 NOTE: For the ARGO 7 installation, not all parts included in the kit are required.
Before starting the installation process, remove power from the ATM by entering Management Functions > Sys-
tem Parameters > Shut Down the Terminal > Enter. When prompted, open the control panel and turn power
switch to o (O) position. Disconnect main power cable from the power supply.
Anti-Skim Card Reader Upgrade
1-3
3. Remove the card reader by removing the four screws shown below. DISCARD CARD READER SCREWS.
If ground wire is attached, remove the screw securing wire.
4. Obtain the Anti-Skim Card Reader from kit number 06200-00355 (see page ii for details). Install the card
reader by inserting it through the front of the control panel. Ensure Triton logo on the Bezel is in the position
shown. (See  gure A). Secure the card reader with the four 3/8” screws provided. (See  gure B).
CAUTION: Be sure to use the screws provided in the kit. DO NOT reuse the screws from step 3; this will cause
damage to the metal inserts on the new card reader.
Figure A
Figure B
I-65Track 1-2
ARGO 7
1-4
5
. Obtain the Card Reader Communication Ribbon Cable from the kit and plug the cable into the card reader.
Fasten the cable securely by pushing in the two tabs on the connector. (See  gure C). Connect the other end of
the Communication Cable to the main board as shown. (See  gure D).
6. Route the Communication Cable through the Cable Clips as shown.
Figure C
Figure D
Anti-Skim Card Reader Upgrade
1-5
7. Secure the ground wire from the card reader to the display bracket with one #8-32 X 3/8 inch Pan Phil Head
w/Ext Tooth Wash screw from kit as shown.
8. Obtain the main board cover (removed during step 1) and secure it to the top of the main board.
9. Connect the main power cable to the power supply and power on the ATM. Close the control panel. REFER
TO SECTION 8 FOR INSTRUCTIONS ON CALIBRATION AND DIAGNOSTICS OF THE ANTISKIM
CARD READER.
SECTION 2
ANTI-SKIM CARD READER
UPGRADE
ARGO 12
KIT 06200-00355
ARGO 12
2-2
1. Unplug the Card Reader Communication Cable from the docking board. Remove the cable from the cable
clips.
2. Remove the card reader by removing the four screws shown below. DISCARD CARD READER SCREWS.
If ground wire is attached, remove the screw securing wire.
ARGO 12 NOTE: For the ARGO 12 installation, not all parts included in the kit are required.
Before starting the installation process, remove power from the ATM by entering Management Functions > Sys-
tem Parameters > Shut Down the Terminal > Enter. When prompted, open the control panel and turn power
switch to o (O) position. Disconnect main power cable from the power supply.
I-65Track 1-2
Anti-Skim Card Reader Upgrade
2-3
3. Obtain the Anti-Skim Card Reader from kit number 06200-00355 (see page ii for details). Install the card
reader by inserting it through the front of the control panel. Ensure Triton logo on the Bezel is in the position
shown. (See  gure A).
4. Secure the card reader with the four 3/8” screws provided. (See  gure B).
CAUTION: Be sure to use the screws provided in the kit. DO NOT reuse the screws from step 2; this will cause
damage to the metal inserts on the new card reader.
Figure A
Figure B
ARGO 12
2-4
5. Obtain the Card Reader Communication Ribbon Cable from the kit and plug the cable into the card reader.
Fasten the cable securely by pushing in the two tabs on the connector. (See  gure C). Connect the other end of
the Communication Cable to the docking board as shown. (See  gure D).
6. Route the Communication Cable through the cable clips as shown.
Figure D
Figure C
Anti-Skim Card Reader Upgrade
2-5
7. Secure the ground wire from the card reader to the display bracket with one #8-32 X 3/8 inch Pan Phil Head
w/Ext Tooth Wash screw from kit as shown.
8. Connect the main power cable to the power supply and power on the ATM. Close the control panel. REFER
TO SECTION 8 FOR INSTRUCTIONS ON CALIBRATION AND DIAGNOSTICS OF THE ANTISKIM
CARD READER.
SECTION 3
ANTI-SKIM CARD READER
UPGRADE
ARGO 15
KIT 06200-00355
ARGO 15
3-2
1. Carefully remove the plastic cover from the main board.
2. Unplug the Card Reader Communication Cable from the main board. Remove the cable from the cable clips.
ARGO 15 NOTE: For the ARGO 15 installation, not all parts included in the kit are required.
Before starting the installation process, remove power from the ATM by entering Management Functions > Sys-
tem Parameters > Shut Down the Terminal > Enter. When prompted, open the control panel and turn power
switch to o (O) position. Disconnect main power cable from the power supply.
Anti-Skim Card Reader Upgrade
3-3
3. Remove the card reader by removing the four screws shown below. DISCARD CARD READER SCREWS.
If ground wire is attached, remove the screw securing wire.
4. Obtain the Anti-Skim Card Reader from kit number 06200-00355 (see page ii for details). Install the card
reader by inserting it through the front of the control panel. Ensure Triton logo on the Bezel is in the position
shown. (See  gure A). Secure the card reader with the four 3/8” screws provided. (See  gure B).
CAUTION: Be sure to use the screws provided in the kit. DO NOT reuse the screws from step 3; this will cause
damage to the metal inserts on the new card reader.
Figure A Figure B
I-65Track 1-2
ARGO 15
3-4
5. Obtain the Card Reader Communication Ribbon Cable from the kit and plug the cable into the card reader.
Fasten the cable securely by pushing in the two tabs on the connector. (See  gure C). Connect the other end of
the Communication Cable to the main board as shown. (See  gure D).
6. Route the Communication Cable through the cable clips as shown.
Figure C
Figure D
Anti-Skim Card Reader Upgrade
3-5
7. Secure the ground wire from the card reader to the display bracket with one #8-32 X 3/8 inch Pan Phil Head
w/Ext Tooth Wash screw from kit as shown.
8. Obtain the main board cover (removed during step 1) and secure it to the top of the main board.
9. Connect the main power cable to the power supply and power on the ATM. Close the control panel. REFER
TO SECTION 8 FOR INSTRUCTIONS ON CALIBRATION AND DIAGNOSTICS OF THE ANTISKIM
CARD READER.
SECTION 4
ANTI-SKIM CARD READER
UPGRADE
RL16XX
KIT 06200-00355
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44

Triton Systems Argo User manual

Type
User manual

Triton Systems Argo: Your high-security ATM card reader featuring advanced anti-skimming technology to safeguard your financial transactions. Experience enhanced card protection and reliable performance with EMV compliance, ensuring secure and efficient card processing.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI