TROVE T1RM3CK1 is a pre-assembled rack kit designed to accommodate one Intelligent Dual Reader Controller and one Dual Reader Interface Module, providing access control and power distribution capabilities. It features a fully assembled enclosure with a backplane, power supply/charger, fused access power controller, dual input fused power distribution module, voltage regulator, and wire harnesses. The kit is suitable for four-door applications and offers various output options, including fail-safe/fail-secure or dry form "C" outputs, with configurable current limits.

TROVE T1RM3CK1 is a pre-assembled rack kit designed to accommodate one Intelligent Dual Reader Controller and one Dual Reader Interface Module, providing access control and power distribution capabilities. It features a fully assembled enclosure with a backplane, power supply/charger, fused access power controller, dual input fused power distribution module, voltage regulator, and wire harnesses. The kit is suitable for four-door applications and offers various output options, including fail-safe/fail-secure or dry form "C" outputs, with configurable current limits.

T1RM3CK1
4 Door Kit with Fused Outputs
Accommodates one (1) Intelligent Dual Reader Controller and
one (1) Dual Reader Interface Module.
Fully assembled kit includes:
- Trove1R rack enclosure with TM1R Altronix/Mercury backplane
- One (1) eFlow6NB - Power Supply/Charger
- One (1) ACM4 - Fused Access Power Controller
- One (1) PDS8 - Dual Input Fused Power Distribution Module
- One (1) VR6 - Voltage Regulator
- Wire harnesses and management
T1RM3CK1D
4 Door Kit with PTC Outputs
Accommodates one (1) Intelligent Dual Reader Controller and
one (1) Dual Reader Interface Module.
Fully assembled kit includes:
- Trove1R rack enclosure with TM1R Altronix/Mercury backplane
- One (1) eFlow6NB - Power Supply/Charger
- One (1) ACM4CB - PTC Access Power Controller
- One (1) PDS8CB - Dual Input PTC Power Distribution Module
- One (1) VR6 - Voltage Regulator
- Wire harnesses and management
Access & Power Integration
Rev. 072423
Installing Company: _________________________ Service Rep. Name: __________________________________________
Address: _________________________________________________________ Phone #: _________________________
All registered trademarks are property of their respective owners. More than just power.™
Installation Guide
Altronix/Mercury Wired Rack Kits
Models Include:
All components of these Trove kits are UL Listed sub-assemblies.
Please refer to the included corresponding Sub-Assembly Installation Guides for further information.
- 2 - T1RM3CK1(D) Series Installation Guide
Overview:
Altronix Trove Mercury wired rack kits are pre-assembled and consist of Trove rack enclosure/backplane with factory installed Altronix power
supply/charger and sub-assemblies. They also accommodate a variety of Mercury modules for up to four doors in a single enclosure.
Configuration Chart:
Altronix
Model Number
120VAC 60Hz
P/S Input Current (A)
Power Supply Board
Input Fuse Rating
Power Supply Board
Battery Fuse Rating
Nominal DC
Output Voltage
Maximum Supply
Current for Main and Aux.
Outputs on
Power Supply board,
PDS8(CB) Power
Distribution Module and
ACM4(CB) Access Power
Controller’s outputs (A)
Current Per
ACM4(CB) Output (A)
ACM4(CB) Board
Input Fuse Rating
ACM4(CB) Board
Output Fuse (PTC)
Rating
Fail-Safe/Fail-Secure
or Dry Form “C”
Outputs
PDS8(CB) Board
Input Fuse (PTC)
Rating
PDS8(CB) Board
Output Fuse (PTC)
Rating
[DC] [Aux]
24VDC
Output
Range
(V)
24VDC
Output
Range
(V)
T1RM3CK1
3.5 5A/
250V
10A/
32V
20.28-
26.4
20.28-
26.4 24VDC @ 5.6A
2.5 10A/
250V
3A/
32V 410A/
32V
3A/
32V
T1RM3CK1D 2.0 10A/
250V 2.5A 4 9A 2.5A
Installation Instructions for T1RM3CK1(D):
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction.
These products are for indoor use only and must be installed within the protected premises.
Note: First assemble and Install Z Bracket Wire Management Accesory
(refer to Z Bracket Installation pg. 3)
1. Remove backplane from enclosure prior to installing into rack cabinet (do not discard hardware).
2. In order to mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) turn the
enclosure upside down. Punch out the knockout in designated location, on the back of the unit,
from outside of the drawer (Fig. 1, pg. 2). Insert the tamper switch into the knockout from outside of the
drawer with the button facing outwards and spaded connectors inside the drawer.
Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device.
To activate alarm signal open the rack drawer.
3. Slide the rack enclosure into an open 2U location in the four post rack cabinet.
4. Utilizing proper fasteners attach front ears to the rack rails.
5. Attach the rear of the adjustable slides to the rear rails of the rack cabinet with the proper fasteners.
6. Secure the rack cover (Fig. 2a, pg. 2) and rack drawer to earth ground (Fig. 2b, pg. 2).
7. Make sure that all internal cofigurations (wiring, voltage selection, switch settings, etc.) are complete before mounting backplane back
into enclosure.
8. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow6NB and corresponding sub-assembly Installation Guides for the
following models: ACM4(CB), PDS8(CB), VR6 for further instructions.
Fig. 1
Back of the drawer,
viewed from outside.
Tamper Switch
mounting location
Fig. 2
Fig. 2a
Fig. 2b
T1RM3CK1(D) Series Installation Guide - 3 -
Assembling and Attaching Z Bracket Wire Management Accessory (included):
Altronix Trove Rack enclosures include Z Bracket, a convenient and reliable wire management accessory.
Hardware (included):
Ten (10) bolts and eight (8) lock nuts.
1. Carefully unpack Z Bracket. Do not discard hardware
(included) (Fig. 3, pg. 3).
2. Attach arms to each other using bolts and
lock nuts (Fig. 3a, pg. 3).
3. Attach the hinge brackets to the ends of
arms using bolts and nuts positioning
them as shown on (Fig. 3b, pg. 3).
4. Make sure that all nuts are tightened.
5. Attach the hinge bracket on the longer side of Z Bracket to the adjustable slide using bolts and lock nuts (included) (Fig. 4, 4a, pg. 3).
6. Attach the hinge bracket on the shorter side of Z Bracket to the rear of the rack enclosure using bolts (included).
Fig. 4
Fig. 4a
Fig. 3b
Two (2)
Fig. 3
Fig. 3a
- 4 - T1RM3CK1(D) Series Installation Guide
T1RM3CK1(D): Configuration of Mercury Boards:
1. Position access controller module over corresponding spacers and depress onto snap on spacers (Fig. 5, pg. 4).
2. Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models:
LenelS2 / Mercury Access Controller Pem Mounting
LNL-2220 / LP1502 A
LNL-1320 / MR52 B
Fig. 5
To LED lense
To IEC connector
D1 D2
IN1IN2 IN3IN4 IN5IN6 IN7IN8
IN9
GND
IN10
INPUTS
IN-5V
OUT-12V
J4
J2
RDR POWER
REG UNREG
GNDDAT CLK BZRLED V0CLKGNDDAT BZRLED V0
READER 1READER 2
PN
REV
SN
TR+
TR-
R+
R-
SG
AC
GND
ACDC
RS-485 12V
J5,J6
TERMINATOR
J5
J6
2W 4W
RS-485
J3
NO CNCNOC NC
RLY 1RLY 2RLY 3RLY 4
NO CNCNOC NC
RLY 5RLY 6
NO CNCNOC NC
65432
18
7
S1
OFF ON
MADE IN USA
READER INTERFACE
U10
COM
C2
C3
NO
NC
K1
C3
C2
COM K3
NO
NC
C3
C2
COM K5
NO
NC
C3
C2
COM K2
NO
NC
C3
C2
COM K4
NO
NC
C3
C2
COM K6
NO
NC
J4
J3
1
2
3
TMP
FLT
R1
R2
+
1
3
2
4
J8
RESET
S2
BT1
3V BR/CR2330
J1
5V
3.3V
2
3
4
1
S1
VBAT
IN1
K
1
K
2
K
3
K
4
K2 K1
K3K4
IN2
IN3
IN4
IN5
IN6
IN7
IN8
8V
J6
J2
J5
J7
PASS 12V
GND
DAT
D0
TB8
READER 1
BZR
VO
GND
FLT
GND
TMP
GND
VIN
TB1
LED
D1
CLK
READER 2
D1
LED
VO
BZR
GND
CLK
D0
DAT
TB9
NO
OUT 1 C
NC
NO
OUT 2 C
NC
NC
OUT 4 C
NC
NO
NO
OUT 3 C
TB10TB11
RXD
CTS
GND
RTS
TXD
TB2
TB3
TR+
GND
TR-
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
TB4
TB5
TB6
TB7
-
Altronix
Power Supply
NC C NO NC C NO
AC FAIL BAT FAIL
TRIGGER
AC DCAC1
EOL NO GND
SUPERVISED RESET
+AUX-
- BAT +- DC +
L G N
OFF - 24V
ON - 12V
ON
Altronix VR6
is mounted
below PDS8(CB)
+ INP1 --
PWR1 +OFF
IN1
IN2
PWR1 +
PWR2 +
PWR2 +
COM (--- )
COM (--- )
+ INP2 --
IN1 Fuse
Common Power Outputs (NEG)
N
P
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8
1 2 3 4 5 6 7 8
Altronix PDS8(CB)
TRG
TRIGGER
INPUT
LED1 LED2 LED3 LED4
MAIN
OUTPUT 1
NC C NO COM NC C NO COM NC C NO COM NC C NO COM
OUTPUT 2 OUTPUT 3
IN GND
1
IN GND
2
IN GND
3
IN GND
4
OUTPUT 4
-- +
CONTROL
-- +
POWER
+INP- T +RET-
INTERFACE
NO C NC
FACP
Altronix ACM4(CB)
(A) LNL-2220
(B) LNL-1320
Snap On
Spacer
Mercury Board
Backplane
Pem
Fig. 5a
T1RM3CK1(D) Series Installation Guide - 5 -
Notes:
- 6 - T1RM3CK1(D) Series Installation Guide
Notes:
T1RM3CK1(D) Series Installation Guide - 7 -
Notes:
- 8 - T1RM3CK1(D) Series Installation Guide
Trove1R Enclosure Dimensions (H x W x D approximate):
3.375” x 19.0” x 26.5” (85.8mm x 482.6mm x 673.1mm). Shown with Z Bracket attached
0.1”
2.5mm
1.5”
38.1mm
11.175” (283.8mm)
Tamper
Switch
3/4” Conduit
1” Conduit
Conduit
3/4”
1/2”
2.4”
61mm
4.57”
116.1mm
3.375”
85.8mm
26.5”
673.1mm
19” (482.6mm)
R 1.27” (32.3mm)
1” (25.4mm)
0.55” (14mm)
3.62”
92mm
Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice.
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
website: www.altronix.com | e-mail: [email protected] | Lifetime Warranty
IIT1RM3CK1(D) G24W MEMBER
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

TROVE T1RM3CK1 Installation guide

Type
Installation guide

TROVE T1RM3CK1 is a pre-assembled rack kit designed to accommodate one Intelligent Dual Reader Controller and one Dual Reader Interface Module, providing access control and power distribution capabilities. It features a fully assembled enclosure with a backplane, power supply/charger, fused access power controller, dual input fused power distribution module, voltage regulator, and wire harnesses. The kit is suitable for four-door applications and offers various output options, including fail-safe/fail-secure or dry form "C" outputs, with configurable current limits.