Altronix T1M1LCK1 is a fully assembled kit designed for access control applications. It includes a Trove1 enclosure with TM1 Altronix/Mercury backplane, AL400ULXB2 power supply/charger, ACM4 fused access power controller, PDS8 dual input fused power distribution module, VR6 voltage regulator, and a rocker switch bracket with a rocker switch. The kit also features integrated wire harnesses and finger duct for ease of installation. It accommodates one intelligent dual reader controller and one dual reader interface module.

Altronix T1M1LCK1 is a fully assembled kit designed for access control applications. It includes a Trove1 enclosure with TM1 Altronix/Mercury backplane, AL400ULXB2 power supply/charger, ACM4 fused access power controller, PDS8 dual input fused power distribution module, VR6 voltage regulator, and a rocker switch bracket with a rocker switch. The kit also features integrated wire harnesses and finger duct for ease of installation. It accommodates one intelligent dual reader controller and one dual reader interface module.

Access & Power Integration
Altronix/Mercury Wired Kits
Models Include:
Installation Guide
All registered trademarks are property of their respective owners.
Rev. 020922
Installing Company: _________________________ Service Rep. Name: ____________________________________________
Address: _________________________________________________________ Phone #: ___________________________
4 Door Kits with Fused Outputs:
T1M1LCK1
Accommodates one (1) Intelligent Dual Reader Controller and
one (1) Dual Reader Interface Modules.
2 Door Kits with Fused Outputs:
T1M1LCK2
Accommodates one (1) Intelligent Controller and one (1) Dual
Reader Interface Module.
4 Door Kits with Fused Outputs:
T1M1LCK3
Accommodates up to two (2) Dual Reader Interface Modules.
Each fully assembled kit includes:
- Trove1 enclosure with TM1 Altronix/Mercury backplane
- One (1) AL400ULXB2 - Power Supply/Charger
- One (1) ACM4 - Fused Access Power Controller
- One (1) PDS8 - Dual Input Fused Power Distribution Module
- One (1) VR6 - Voltage Regulator
- One (1) Rocker Switch Bracket with One (1) Rocker Switch
4 Door Kits with PTC Outputs:
T1M1LCK1D
Accommodates one (1) Intelligent Dual Reader Controller and
one (1) Dual Reader Interface Module.
2 Door Kits with Fused Outputs:
T1M1LCK2D
Accommodates one (1) Intelligent Controller and one (1) Dual
Reader Interface Module.
4 Door Kits with Fused Outputs:
T1M1LCK3D
Accommodates up to two (2) Dual Reader Interface Modules.
Each fully assembled kit includes:
- Trove1 enclosure with TM1 Altronix/Mercury backplane
- One (1) AL400ULXB2 - Power Supply/Charger
- One (1) ACM4CB - PTC Access Power Controller
- One (1) PDS8CB - Dual Input PTC Power Distribution Module
- One (1) VR6 - Voltage Regulator
- One (1) Rocker Switch Bracket with One (1) Rocker Switch
- 2 - T1M1LCK Series Installation Guide
Overview:
Altronix Trove Plus kits are pre-wired, pre-assembled and consist of Trove1M1 enclosure/backplane with factory installed Altronix power supply/
charger and sub-assemblies, wire harnesses and finger duct.
Configuration Chart:
Altronix
Model
Number
115VAC
60Hz
Input
Current
(A)
Power
Supply
Board
Input
Fuse
Rating
Power
Supply
Board
Battery
Fuse
Rating
Nominal DC Output
Voltage
Maximum Supply
Current for Main
Outputs on Power
Supply board and
ACM4(CB) Access
Power Controller’s
outputs
Fail-Safe/Fail-Secure or
Dry Form “C” Outputs
ACM4(CB) Board
Input Fuse (PTC) Rating
ACM4(CB) Board
Output Fuse (PTC) Rating
PDS8(CB) Board
Input Fuse (PTC) Rating
PDS8(CB) Board
Output Fuse (PTC) Rating
Power
Supply 1
Power
Supply 2
Output
Range
(VDC)
Output
Range
(VDC)
T1M71LCK1
3.0 5A/
250V
15A/
32V
20.17-
26.4
20.17-
26.4 24VDC @ 3.8A 4
10A/
250V
3A/
250V
10A/
250V
3A/
250V
T1M71LCK2
T1M71LCK3
T1M71LCK1D
10A/
250V 2.5A 9A 2.5A
T1M71LCK2D
T1M71LCK3D
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having
jurisdiction. Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the
wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws; level and secure.
Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners.
Place the enclosure’s upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired location, opposite hinge. Slide the tamper switch
bracket onto the edge of the enclosure approximately 2” from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the Access
Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure.
4. Mount Mercury modules to backplane(s), refer to page 3.
5. Refer to the ULXB Power Supply/Charger Installation Guide for AL400ULXB2
and corresponding Installation Guides for PDS8(CB), VR6, and ACM4(CB)
for further installation instructions.
Fig. 1
Tamper Switch
(included)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure
Altronix is not responsible for any typographical errors.
T1M1LCK Series Installation Guide - 3 -
T1M1LCK1(D): Configuration of Mercury Boards:
1. Position access controller module over corresponding spacers and depress onto snap on spacers (Fig. 3, pg. 4).
2. Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models:
Mercury Access Controller Pem Mounting
LNL-2220 / LP1502 / LP4502 A
LNL-1320 / MR52 B
Fig. 2
DAT
J4
J3
1
2
3
TMP
FLT
R1
R2
+
1
3
2
4
J8
RESET
S2
BT1
3V BR/CR2330
2
3
4
1
S1
VBAT
IN1
K
1
K
2
K
3
K
4
K2 K1
K3K4
IN2
IN3
IN4
IN5
IN6
IN7
IN8
8V
J6
J2
J5
J7
PASS 12V
GND
DAT
D0
TB8
READER 1
BZR
VO
GND
FLT
GND
TMP
GND
VIN
TB1
LED
D1
CLK
READER 2
D1
LED
VO
BZR
GND
CLK
D0
DAT
TB9
NO
OUT 1 C
NC
NO
OUT 2 C
NC
NC
OUT 4 C
NC
NO
NO
OUT 3 C
TB10TB11
RXD
CTS
GND
RTS
TXD
TB2
TB3
TR+
GND
TR-
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
TB4
TB5
TB6
TB7
-
D1 D2
IN1IN2 IN3IN4 IN5IN6 IN7IN8
IN9
GND
IN10
INPUTS
IN-5V
OUT-12V
J4
J2
RDR POWER
REG UNREG
GNDDAT CLK BZRLED V0CLKGNDDAT BZRLED V0
READER 1READER 2
PN
REV
SN
TR+
TR-
R+
R-
SG
AC
GND
ACDC
RS-485 12V
J5,J6
TERMINATOR
J5
J6
2W 4W
RS-485
J3
NO CNCNOC NC
RLY 1RLY 2RLY 3RLY 4
NO CNCNOC NC
RLY 5RLY 6
NO CNCNOC NC
65432
18
7
S1
OFF ON
READER INTERFACE
U10
COM
C2
C3
NO
NC
K1
C3
C2
COM K3
NO
NC
C3
C2
COM K5
NO
NC
C3
C2
COM K2
NO
NC
C3
C2
COM K4
NO
NC
C3
C2
COM K6
NO
NC
RSB1
Altronix PDS8(CB)
PDS8(CB) is stacked above VR6
(A)
LNL-2220,
LP1502/
LP4502
(B)
LNL-1320,
MR52
TRG
TRIGGER
INPUT
ACM4
ACCESS POWER
CONTROLLER
LED1 LED2 LED3 LED4
MAIN
OUTPUT 1
NC C NO COM NC C NO COM NC C NO COM NC C NO COM
OUTPUT 2 OUTPUT 3
IN GND
1
IN GND
2
IN GND
3
IN GND
4
OUTPUT 4
-- +
CONTROL
-- +
POWER
+INP- T +RET-
INTERFACE
NO C NC
FACP
Altronix ACM4(CB)
+ INP1 --
PWR1 +
PWR1 +
OFF
IN1
IN2
Out1
<1 off 2>
PWR2 +PWR2 +
COM ---
COM ---
+ INP2 --
IN2 Fuse
IN1 Fuse
Common Power Outputs (NEG)
N
P
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8
1 2 3 4 5 6 7 8
Out2
<1 off 2>
Out3
<1 off 2>
Out4
<1 off 2>
Out5
<1 off 2>
Out6
<1 off 2>
Out7
<1 off 2>
Out8
<1 off 2>
L G N BAT FAIL NC C NO NC C NO AC FAIL
AC
+ BAT - + DC -
DC BAT
F1
Off - 24V
On - 12V
SW1
ON
Altronix
AL400ULXB2
Snap On
Spacer
Mercury Board
Backplane
Pem
Fig. 2a
- 4 - T1M1LCK Series Installation Guide
T1M1LCK2(D): Configuration of Mercury Boards:
1. Position access controller module over corresponding spacers and depress onto snap on spacers (Fig. 3, pg. 4).
2. Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models:
Mercury Access Controller Pem Mounting
LNL-3300 / LP2500 A
LNL-1320 / MR52 B
Fig. 3
D1 D2
IN1IN2 IN3IN4 IN5IN6 IN7IN8
IN9
GND
IN10
INPUTS
IN-5V
OUT-12V
J4
J2
RDR POWER
REG UNREG
GNDDAT CLK BZRLED V0CLKGNDDAT BZRLED V0
READER 1READER 2
PN
REV
SN
TR+
TR-
R+
R-
SG
AC
GND
ACDC
RS-485 12V
J5,J6
TERMINATOR
J5
J6
2W 4W
RS-485
J3
NO CNCNOC NC
RLY 1RLY 2RLY 3RLY 4
NO CNCNOC NC
RLY 5RLY 6
NO CNCNOC NC
65432
18
7
S1
OFF ON
READER INTERFACE
U10
COM
C2
C3
NO
NC
K1
C3
C2
COM K3
NO
NC
C3
C2
COM K5
NO
NC
C3
C2
COM K2
NO
NC
C3
C2
COM K4
NO
NC
C3
C2
COM K6
NO
NC
RSB1
Altronix PDS8(CB)
PDS8(CB) is stacked above VR6
(A)
LNL-3300,
LP2500
(B)
LNL-1320,
MR52
TRG
TRIGGER
INPUT
ACM4
ACCESS POWER
CONTROLLER
LED1 LED2 LED3 LED4
MAIN
OUTPUT 1
NC C NO COM NC C NO COM NC C NO COM NC C NO COM
OUTPUT 2 OUTPUT 3
IN GND
1
IN GND
2
IN GND
3
IN GND
4
OUTPUT 4
-- +
CONTROL
-- +
POWER
+INP- T +RET-
INTERFACE
NO C NC
FACP
Altronix ACM4(CB)
+ INP1 --
PWR1 +
PWR1 +
OFF
IN1
IN2
Out1
<1 off 2>
PWR2 +PWR2 +
COM ---
COM ---
+ INP2 --
IN2 Fuse
IN1 Fuse
Common Power Outputs (NEG)
N
P
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8
1 2 3 4 5 6 7 8
Out2
<1 off 2>
Out3
<1 off 2>
Out4
<1 off 2>
Out5
<1 off 2>
Out6
<1 off 2>
Out7
<1 off 2>
Out8
<1 off 2>
L G N BAT FAIL NC C NO NC C NO AC FAIL
AC
+ BAT - + DC -
DC BAT
F1
Off - 24V
On - 12V
SW1
ON
Altronix
AL400ULXB2
RESET
S2
BT1
3V BR/CR2330
GND
FLT
GND
TMP
GND
VIN
TB1
TR+
TR-
GND
TB3
TR+
TR-
GND
TB4
Snap On
Spacer
Mercury Board
Backplane
Pem
Fig. 3a
T1M1LCK Series Installation Guide - 5 -
T1M1LCK3(D): Configuration of Mercury Boards:
1. Position access controller module over corresponding spacers and depress onto snap on spacers (Fig. 3, pg. 4).
2. Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models:
Mercury Access Controller Pem Mounting
LNL-1320 / MR52 A
LNL-1320 / MR52 B
Fig. 3
DAT
D1 D2
IN1IN2 IN3IN4 IN5IN6 IN7IN8
IN9
GND
IN10
INPUTS
IN-5V
OUT-12V
J4
J2
RDR POWER
REG UNREG
GNDDAT CLK BZRLED V0CLKGNDDAT BZRLED V0
READER 1READER 2
PN
REV
SN
TR+
TR-
R+
R-
SG
AC
GND
ACDC
RS-485 12V
J5,J6
TERMINATOR
J5
J6
2W 4W
RS-485
J3
NO CNCNOC NC
RLY 1RLY 2RLY 3RLY 4
NO CNCNOC NC
RLY 5RLY 6
NO CNCNOC NC
65432
18
7
S1
OFF ON
READER INTERFACE
U10
COM
C2
C3
NO
NC
K1
C3
C2
COM K3
NO
NC
C3
C2
COM K5
NO
NC
C3
C2
COM K2
NO
NC
C3
C2
COM K4
NO
NC
C3
C2
COM K6
NO
NC
D1 D2
IN1IN2 IN3IN4 IN5IN6 IN7IN8
IN9
GND
IN10
INPUTS
IN-5V
OUT-12V
J4
J2
RDR POWER
REG UNREG
GNDDAT CLK BZRLED V0CLKGNDDAT BZRLED V0
READER 1READER 2
PN
REV
SN
TR+
TR-
R+
R-
SG
AC
GND
ACDC
RS-485 12V
J5,J6
TERMINATOR
J5
J6
2W 4W
RS-485
J3
NO CNCNOC NC
RLY 1RLY 2RLY 3RLY 4
NO CNCNOC NC
RLY 5RLY 6
NO CNCNOC NC
65432
18
7
S1
OFF ON
READER INTERFACE
U10
COM
C2
C3
NO
NC
K1
C3
C2
COM K3
NO
NC
C3
C2
COM K5
NO
NC
C3
C2
COM K2
NO
NC
C3
C2
COM K4
NO
NC
C3
C2
COM K6
NO
NC
RSB1
Altronix PDS8(CB)
PDS8(CB) is stacked above VR6
(A)
LNL-1320,
MR52
(B)
LNL-1320,
MR52
TRG
TRIGGER
INPUT
ACM4
ACCESS POWER
CONTROLLER
LED1 LED2 LED3 LED4
MAIN
OUTPUT 1
NC C NO COM NC C NO COM NC C NO COM NC C NO COM
OUTPUT 2 OUTPUT 3
IN GND
1
IN GND
2
IN GND
3
IN GND
4
OUTPUT 4
-- +
CONTROL
-- +
POWER
+INP- T +RET-
INTERFACE
NO C NC
FACP
Altronix ACM4(CB)
+ INP1 --
PWR1 +
PWR1 +
OFF
IN1
IN2
Out1
<1 off 2>
PWR2 +PWR2 +
COM ---
COM ---
+ INP2 --
IN2 Fuse
IN1 Fuse
Common Power Outputs (NEG)
N
P
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8
1 2 3 4 5 6 7 8
Out2
<1 off 2>
Out3
<1 off 2>
Out4
<1 off 2>
Out5
<1 off 2>
Out6
<1 off 2>
Out7
<1 off 2>
Out8
<1 off 2>
L G N BAT FAIL NC C NO NC C NO AC FAIL
AC
+ BAT - + DC -
DC BAT
F1
Off - 24V
On - 12V
SW1
ON
Altronix
AL400ULXB2
Snap On
Spacer
Mercury Board
Backplane
Pem
Fig. 3a
- 6 - T1M1LCK Series Installation Guide
Notes:
T1M1LCK Series Installation Guide - 7 -
Notes:
- 8 - T1M1LCK Series Installation Guide
Trove1 Enclosure Dimensions (H x W x D approximate):
18” x 14.5” x 4.625” (457mm x 368mm x 118mm)
14.5”
(321.31mm)
13.0”
(330.2mm)
1.45”
(36.83mm)
7.25”
(184.15mm)
4.5”
(114.3mm)
4.5”
(114.3mm) 4.5”
(114.3mm) 2.75”
(69.85mm)
1.25”
(31.75mm)
1.5”
(38.09mm)
8.5”
(215.9mm)
18.0”
(457.2mm)
0.5897”
(14.98mm)
1.0958”
(27.83mm)
0.6012”
(15.27mm)
6.5”
(165.1mm)
1.25”
(31.75mm)
1.25”
(31.75mm)
1.5”
(38.09mm)
8.5”
(215.9mm)
6.5”
(165.1mm)
0.569”
(14.52mm)
1.5” Conduit
1” Conduit
3/4” Conduit
1” Conduit
3/4” Conduit
1” Conduit
3/4” Conduit
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
web site: www.altronix.com | e-mail: [email protected] | Lifetime Warranty
IIT1M1LCK1 E19V MEMBER
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Altronix T1M1LCK1 Installation guide

Category
Security door controllers
Type
Installation guide

Altronix T1M1LCK1 is a fully assembled kit designed for access control applications. It includes a Trove1 enclosure with TM1 Altronix/Mercury backplane, AL400ULXB2 power supply/charger, ACM4 fused access power controller, PDS8 dual input fused power distribution module, VR6 voltage regulator, and a rocker switch bracket with a rocker switch. The kit also features integrated wire harnesses and finger duct for ease of installation. It accommodates one intelligent dual reader controller and one dual reader interface module.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI