  • Hello! I've reviewed the Installation Guide for Altronix Door Controller Kit T2M7LXK series. This document provides detailed instructions for installing and configuring these pre-wired kits, which include features like fused and PTC output options, support for Mercury access controllers, and a variety of door configurations. I’m ready to answer your questions about the installation process or the device in general.
  • What does each fully assembled kit include?
    What Mercury access controller modules are supported?
    What are the main differences between 'V' and 'DV' models?
Please refer to the included corresponding Sub-Assembly Installation Guides for further information.
T2M7LXK1V
8 Door Kit with Fused Outputs
Accommodates one (1) Intelligent Dual Reader Controller and
three (3) Dual Reader Interface Modules.
T2M7LXK2V
6 Door Kit with Fused Outputs
Accommodates one (1) Intelligent Controller and three (3) Dual
Reader Interface Module.
T2M7LXK3V
8 Door Kit with Fused Outputs
Accommodates up to four (4) Dual Reader Interface Modules.
Each fully assembled kit includes:
- Trove2 enclosure with TM2 Altronix/Mercury backplane
- One (1) AL1024XB2V - Power Supply/Charger
- One (1) ACMS8 - Dual Input/Output Fuse Protected
Access Power Controller
- One (1) VR6 - Voltage Regulator
- One (1) PDS8 - Dual Input/Output Fuse Protected
Power Distribution Module
- One (1) Rocker Switch Bracket with One (1) Rocker Switch
- Wire harnesses and finger duct
T2M7LXK1DV
8 Door Kit with PTC Outputs
Accommodates one (1) Intelligent Dual Reader Controller and
three (3) Dual Reader Interface Modules.
T2M7LXK2DV
6 Door Kit with PTC Outputs
Accommodates one (1) Intelligent Controller and three (3) Dual
Reader Interface Module.
T2M7LXK3DV
8 Door Kit with PTC Outputs
Accommodates up to four (4) Dual Reader Interface Modules.
Each fully assembled kit includes:
- Trove2 enclosure with TM2 Altronix/Mercury backplane
- One (1) AL1024XB2V - Power Supply/Charger
- One (1) ACMS8CB - Dual Input/Output PTC Protected
Access Power Controller
- One (1) VR6 - Voltage Regulator
- One (1) PDS8CB - Dual Input/Output PTC Protected
Power Distribution Module
- One (1) Rocker Switch Bracket with One (1) Rocker Switch
- Wire harnesses and finger duct
Access & Power Integration
Rev. T2M7LXKV_070623
Installing Company: _________________________ Service Rep. Name: __________________________________________
Address: _________________________________________________________ Phone #: _________________________
All registered trademarks are property of their respective owners. More than just power.™
Installation Guide
Altronix/Mercury Wired Kits
Models Include:
- 2 - T2M7LXKV Kit Series Installation Guide
Overview:
Altronix Trove Plus kits are pre-wired, pre-assembled and consist of Trove2M2 enclosure/backplane with factory installed Altronix power supply/
charger and sub-assemblies, wire harnesses and finger duct.
Configuration Chart:
Altronix
Model
Number
220VAC
60Hz
Input
Current
(A)
Power
Supply
Board
Input
Fuse
Rating
Power
Supply
Board
Battery
Fuse
Rating
Nominal
DC Output
Voltage
Range
(VDC)
Maximum Supply
Current for Main
Outputs on Power
Supply board and
ACMS8(CB) Access
Power Controller’s
outputs
Fail-Safe/Fail-Secure or
Dry Form “C” Outputs
Current Per ACMS8(CB)
and PDS8(CB) Output (A)
ACMS8(CB) Board
Input Fuse (PTC) Rating
ACMS8(CB) Board
Output Fuse (PTC) Rating
PDS8(CB) Board
Input Fuse (PTC) Rating
PDS8(CB) Board
Output Fuse (PTC) Rating
T2M7LXK1V
2.7 5A/
250V
15A/
32V
20.17-
26.4 24VDC @ 9.4A 8
2.5 15A/
250V
3A/
250V
10A/
250V
3A/
250V
T2M7LXK2V
T2M7LXK3V
T2M7LXK1DV
2.0 9A 2.5A 9A 2.5AT2M7LXK2DV
T2M7LXK3DV
Hardware and Accessories:
One(1) tamper switch (Altronix Model TS112 or equivalent).
Cam lock.
Battery leads.
Mechanical:
16 Gauge enclosure with ample knockouts for convenient access.
• Enclosure Dimensions (H x W x D): 27.25” x 21.75” x 6.5” (692.2mm x 552.5mm x 165.1mm).
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction.
Product is intended for indoor use only.
1. Remove backplane from enclosure. Do not discard hardware.
2. Mark and predrill holes in the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the
wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws, level and secure. Mark the position
of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes
over the three upper screws. Install the three lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch (Altronix Model TS112 or equivalent) in desired
location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure
approximately 2” from the right side (Fig. 1, pg. 2). Connect tamper switch wiring to the
Access Control Panel input or the appropriate UL Listed reporting device.
To activate alarm signal open the door of the enclosure.
4. Refer to the XBV Power Supply/Charger Installation Guide for AL1024XB2V
and corresponding Sub-Assembly Installation Guides for PDS8(CB) and ACMS8(CB) for
further installation instructions.
5. Position Mercury access controller modules over corresponding spacers and depress onto
snap on spacers (Fig. 2, pg. 3).
6. Connect wire harnesses to Mercury access controller modules(Fig. 2-4, pg. 3-5).
7. Mount backplane to enclosure with hardware.
Fig. 1
Tamper Switch
(included)
To Access Control Panel or
UL Listed Reporting Device
Edge of
Enclosure
Enclosure
T2M7LXKV Kit Series Installation Guide - 3 -
T2M7LXK1(D)V Configuration:
1. Position access controller module over corresponding spacers and depress onto snap on spacers (Fig. 2, pg. 3).
2. Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models:
Mercury Access Controller Pem Mounting
LP1502 / LP4502 A
LNL-1320 / MR52 B C D
Fig. 2
D1 D2
IN1IN2 IN3IN4 IN5IN6 IN7 IN8
IN9
GND
IN10
INPUTS
IN-5V
OUT-12V
J4
J2
RDR POWER
REG UNREG
GNDDAT CLKBZR LEDV0CLKGND DAT BZR LEDV0
READER 1READER 2
PN
REV
SN
TR+
TR-
R+
R-
SG
AC
GND
ACDC
RS-485 12V
J5,J6
TERMINATOR
J5
J6
2W 4W
RS-485
J3
NO CNCNOC NC
RLY 1RLY 2RLY 3RLY 4
NO CNCNOC NC
RLY 5RLY 6
NO CNCNOC NC
65432
18
7
S1
OFF ON
READER INTERFACE
U10
COM
C2
C3 NO
NC
K1
C3
C2
COM K3
NO
NC
C3
C2
COM K5
NO
NC
C3
C2
COM K2
NO
NC
C3
C2
COM K4
NO
NC
C3
C2
COM K6
NO
NC
D1 D2
IN1 IN2 IN3IN4 IN5IN6 IN7 IN8
IN9
GND
IN10
INPUTS
IN-5V
OUT-12V
J4
J2
RDR POWER
REG UNREG
GND DATCLK BZR LED V0CLKGND DAT BZR LED V0
READER 1READER 2
PN
REV
SN
TR+
TR-
R+
R-
SG
AC
GND
ACDC
RS-485 12V
J5,J6
TERMINATOR
J5
J6
2W 4W
RS-485
J3
NO CNCNOC NC
RLY 1RLY 2RLY 3RLY 4
NO CNCNOC NC
RLY 5RLY 6
NO CNCNOC NC
65432
18
7
S1
OFF ON
READER INTERFACE
U10
COM
C2
C3 NO
NC
K1
C3
C2
COM K3
NO
NC
C3
C2
COM K5
NO
NC
C3
C2
COM K2
NO
NC
C3
C2
COM K4
NO
NC
C3
C2
COM K6
NO
NC
D1 D2
IN1IN2 IN3IN4 IN5IN6 IN7IN8
IN9
GND
IN10
INPUTS
IN-5V
OUT-12V
J4
J2
RDR POWER
REG UNREG
GND DATCLK BZR LED V0CLKGND DATBZR LEDV0
READER 1READER 2
PN
REV
SN
TR+
TR-
R+
R-
SG
AC
GND
ACDC
RS-485 12V
J5,J6
TERMINATOR
J5
J6
2W 4W
RS-485
J3
NO CNCNOC NC
RLY 1RLY 2RLY 3RLY 4
NO CNCNOC NC
RLY 5RLY 6
NO CNCNOC NC
65432
18
7
S1
OFF ON
READER INTERFACE
U10
COM
C2
C3 NO
NC
K1
C3
C2
COM K3
NO
NC
C3
C2
COM K5
NO
NC
C3
C2
COM K2
NO
NC
C3
C2
COM K4
NO
NC
C3
C2
COM K6
NO
NC
J4
J3
1
2
3
TMP
FLT
R1
R2
+
1
3
2
4
J8
RESET
S2
BT1
3V BR/CR2330
J1
5V
3.3V
2
3
4
1
S1
VBAT
IN1
K
1
K
2
K
3
K
4
K2 K1
K3K4
IN2
IN3
IN4
IN5
IN6
IN7
IN8
8V
J6
J2
J5
J7
PASS 12V
GND
DAT
D0
TB8
READER 1
BZR
VO
GND
FLT
GND
TMP
GND
VIN
TB1
LED
D1
CLK
READER 2
D1
LED
VO
BZR
GND
CLK
D0
DAT
TB9
NO
OUT 1 C
NC
NO
OUT 2 C
NC
NC
OUT 4 C
NC
NO
NO
OUT 3 C
TB10TB11
RXD
CTS
GND
RTS
TXD
TB2
TB3
TR+
GND
TR-
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
TB4
TB5
TB6
TB7
-
(A) LNL-2220,
LP1502 / LP4502
(D) LNL-1320,
MR52
(C) LNL-1320,
MR52
(B) LNL-1320,
MR52
L
G
N
BAT FAIL
AC FAIL
NC
C
NO
NC
C
NO
AC
DC
- BAT + + DC -
AC DELAY
Altronix AL1024ULXB2
Altronix VR6 is mounted under ACMS8(CB)
PWR1 +
PWR2 +
COM -
COM -
PWR2 +
PWR1 +
+ PWR2 --
+ PWR1 --
Altronix ACMS8(CB)
+ INP1 --
PWR1 +OFF
IN1
IN2
PWR1 +
PWR2 +
PWR2 +
COM (--- )
COM (--- )
+ INP2 --
IN1 Fuse
Common Power Outputs (NEG)
N
P
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8
1 2 3 4 5 6 7 8
Altronix PDS8(CB)
RSB1
Altronix AL1024XB2V
- 4 - T2M7LXKV Kit Series Installation Guide
T2M7LXK2(D)V Configuration:
1. Position access controller module over corresponding spacers and depress onto snap on spacers (Fig. 3, pg. 4).
2. Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models:
Mercury Access Controller Pem Mounting
LNL-3300 / LP2500 A
LNL-1320 / MR52 B C D
Fig. 3
D1 D2
IN1IN2 IN3IN4 IN5 IN6 IN7IN8
IN9
GND
IN10
INPUTS
IN-5V
OUT-12V
J4
J2
RDR POWER
REG UNREG
GND DAT CLK BZR LED V0CLKGNDDAT BZR LED V0
READER 1READER 2
PN
REV
SN
TR+
TR-
R+
R-
SG
AC
GND
ACDC
RS-485 12V
J5,J6
TERMINATOR
J5
J6
2W 4W
RS-485
J3
NO CNCNOC NC
RLY 1RLY 2RLY 3RLY 4
NO CNCNOC NC
RLY 5RLY 6
NO CNCNOC NC
65432
18
7
S1
OFF ON
READER INTERFACE
U10
COM
C2
C3 NO
NC
K1
C3
C2
COM K3
NO
NC
C3
C2
COM K5
NO
NC
C3
C2
COM K2
NO
NC
C3
C2
COM K4
NO
NC
C3
C2
COM K6
NO
NC
D1 D2
IN1IN2 IN3IN4 IN5 IN6 IN7 IN8
IN9
GND
IN10
INPUTS
IN-5V
OUT-12V
J4
J2
RDR POWER
REG UNREG
GND DATCLK BZR LED V0CLKGNDDAT BZR LED V0
READER 1READER 2
PN
REV
SN
TR+
TR-
R+
R-
SG
AC
GND
ACDC
RS-485 12V
J5,J6
TERMINATOR
J5
J6
2W 4W
RS-485
J3
NO CNCNOC NC
RLY 1RLY 2RLY 3RLY 4
NO CNCNOC NC
RLY 5RLY 6
NO CNCNOC NC
65432
18
7
S1
OFF ON
READER INTERFACE
U10
COM
C2
C3 NO
NC
K1
C3
C2
COM K3
NO
NC
C3
C2
COM K5
NO
NC
C3
C2
COM K2
NO
NC
C3
C2
COM K4
NO
NC
C3
C2
COM K6
NO
NC
D1 D2
IN1IN2 IN3IN4 IN5IN6 IN7IN8
IN9
GND
IN10
INPUTS
IN-5V
OUT-12V
J4
J2
RDR POWER
REG UNREG
GND DATCLK BZR LED V0CLKGND DAT BZR LED V0
READER 1READER 2
PN
REV
SN
TR+
TR-
R+
R-
SG
AC
GND
ACDC
RS-485 12V
J5,J6
TERMINATOR
J5
J6
2W 4W
RS-485
J3
NO CNCNOC NC
RLY 1RLY 2RLY 3RLY 4
NO CNCNOC NC
RLY 5RLY 6
NO CNCNOC NC
65432
18
7
S1
OFF ON
READER INTERFACE
U10
COM
C2
C3 NO
NC
K1
C3
C2
COM K3
NO
NC
C3
C2
COM K5
NO
NC
C3
C2
COM K2
NO
NC
C3
C2
COM K4
NO
NC
C3
C2
COM K6
NO
NC
(A) LNL-3300,
LP2500
(D) LNL-1320,
MR52 (C) LNL-1320,
MR52
(B) LNL-1320,
MR52
RESET
S2
BT1
3V BR/CR2330
GND
FLT
GND
TMP
GND
VIN
TB1
TR+
TR-
GND
TB3
TR+
TR-
GND
TB4
L
G
N
BAT FAIL
AC FAIL
NC
C
NO
NC
C
NO
AC
DC
- BAT + + DC -
AC DELAY
Altronix AL1024ULXB2
Altronix VR6 is mounted under ACMS8(CB)
PWR1 +
PWR2 +
COM -
COM -
PWR2 +
PWR1 +
+ PWR2 --
+ PWR1 --
Altronix ACMS8(CB)
+ INP1 --
PWR1 +OFF
IN1
IN2
PWR1 +
PWR2 +
PWR2 +
COM (--- )
COM (--- )
+ INP2 --
IN1 Fuse
Common Power Outputs (NEG)
N
P
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8
1 2 3 4 5 6 7 8
Altronix PDS8(CB)
RSB1
Altronix AL1024XB2V
T2M7LXKV Kit Series Installation Guide - 5 -
T2M7LXK3(D)V Configuration:
1. Position access controller module over corresponding spacers and depress onto snap on spacers (Fig. 4, pg. 5.
2. Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models:
Mercury Access Controller Pem Mounting
LNL-1320 / MR52 A B C D
Fig. 4
D1 D2
IN1IN2 IN3IN4 IN5IN6 IN7IN8
IN9
GND
IN10
INPUTS
IN-5V
OUT-12V
J4
J2
RDR POWER
REG UNREG
GND DATCLK BZR LED V0CLKGND DAT BZR LED V0
READER 1READER 2
PN
REV
SN
TR+
TR-
R+
R-
SG
AC
GND
ACDC
RS-485 12V
J5,J6
TERMINATOR
J5
J6
2W 4W
RS-485
J3
NO CNCNOC NC
RLY 1RLY 2RLY 3RLY 4
NO CNCNOC NC
RLY 5RLY 6
NO CNCNOC NC
65432
18
7
S1
OFF ON
READER INTERFACE
U10
COM
C2
C3 NO
NC
K1
C3
C2
COM K3
NO
NC
C3
C2
COM K5
NO
NC
C3
C2
COM K2
NO
NC
C3
C2
COM K4
NO
NC
C3
C2
COM K6
NO
NC
D1 D2
IN1IN2 IN3IN4 IN5IN6 IN7IN8
IN9
GND
IN10
INPUTS
IN-5V
OUT-12V
J4
J2
RDR POWER
REG UNREG
GND DATCLK BZR LED V0CLKGND DAT BZR LED V0
READER 1READER 2
PN
REV
SN
TR+
TR-
R+
R-
SG
AC
GND
ACDC
RS-485 12V
J5,J6
TERMINATOR
J5
J6
2W 4W
RS-485
J3
NO CNCNOC NC
RLY 1RLY 2RLY 3RLY 4
NO CNCNOC NC
RLY 5RLY 6
NO CNCNOC NC
65432
18
7
S1
OFF ON
READER INTERFACE
U10
COM
C2
C3 NO
NC
K1
C3
C2
COM K3
NO
NC
C3
C2
COM K5
NO
NC
C3
C2
COM K2
NO
NC
C3
C2
COM K4
NO
NC
C3
C2
COM K6
NO
NC
D1 D2
IN1IN2 IN3IN4 IN5 IN6 IN7 IN8
IN9
GND
IN10
INPUTS
IN-5V
OUT-12V
J4
J2
RDR POWER
REG UNREG
GND DATCLK BZR LED V0CLKGND DAT BZR LED V0
READER 1READER 2
PN
REV
SN
TR+
TR-
R+
R-
SG
AC
GND
ACDC
RS-485 12V
J5,J6
TERMINATOR
J5
J6
2W 4W
RS-485
J3
NO CNCNOC NC
RLY 1RLY 2RLY 3RLY 4
NO CNCNOC NC
RLY 5RLY 6
NO CNCNOC NC
65432
18
7
S1
OFF ON
READER INTERFACE
U10
COM
C2
C3 NO
NC
K1
C3
C2
COM K3
NO
NC
C3
C2
COM K5
NO
NC
C3
C2
COM K2
NO
NC
C3
C2
COM K4
NO
NC
C3
C2
COM K6
NO
NC
D1 D2
IN1IN2 IN3IN4 IN5IN6 IN7IN8
IN9
GND
IN10
INPUTS
IN-5V
OUT-12V
J4
J2
RDR POWER
REG UNREG
GND DATCLK BZRLED V0CLKGND DATBZR LEDV0
READER 1READER 2
PN
REV
SN
TR+
TR-
R+
R-
SG
AC
GND
ACDC
RS-485 12V
J5,J6
TERMINATOR
J5
J6
2W 4W
RS-485
J3
NO CNCNOC NC
RLY 1RLY 2RLY 3RLY 4
NO CNCNOC NC
RLY 5RLY 6
NO CNCNOC NC
65432
18
7
S1
OFF ON
READER INTERFACE
U10
COM
C2
C3 NO
NC
K1
C3
C2
COM K3
NO
NC
C3
C2
COM K5
NO
NC
C3
C2
COM K2
NO
NC
C3
C2
COM K4
NO
NC
C3
C2
COM K6
NO
NC
PDS8(CB)
(D) LNL-1320,
MR52
(C) LNL-1320,
MR52
(B) LNL-1320,
MR52
(A) LNL-1320,
MR52
L
G
N
BAT FAIL
AC FAIL
NC
C
NO
NC
C
NO
AC
DC
- BAT + + DC -
AC DELAY
Altronix AL1024ULXB2
Altronix VR6 is mounted under ACMS8(CB)
PWR1 +
PWR2 +
COM -
COM -
PWR2 +
PWR1 +
+ PWR2 --
+ PWR1 --
Altronix ACMS8(CB)
+ INP1 --
PWR1 +OFF
IN1
IN2
PWR1 +
PWR2 +
PWR2 +
COM (--- )
COM (--- )
+ INP2 --
IN1 Fuse
Common Power Outputs (NEG)
N
P
OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 OUT8
1 2 3 4 5 6 7 8
Altronix PDS8(CB)
RSB1
Altronix AL1024XB2V
- 6 - T2M7LXKV Kit Series Installation Guide
Notes:
T2M7LXKV Kit Series Installation Guide - 7 -
Notes:
- 8 - T2M7LXKV Kit Series Installation Guide
Trove2 Enclosure Dimensions (H x W x D approximate):
27.25” x 21.5” x 6.5” (692.2mm x 552.5mm x 165.1mm)
6.75” (171.5mm)8.25” (209.5mm)
8.00” (203.2mm)
2.00” (50.8mm)
2.00” (50.8mm)
1.25” (31.8mm)
1.25” (31.8mm)
5.25” (133.4mm) 5.25” (133.4mm)7.00” (177.8mm)
1.25” (31.8mm)
6.25” (158.8mm) 19.80” (502.9mm)
1.00” (25.4mm)
27” (685.8mm)
1.5”
(38.1mm)
2.00” (50.8mm) 2.00” (50.8mm)
3.5”(88.9mm) 3.5”(88.9mm)
21.50” (546.1mm)
5.25” (133.35mm) 5.25” (133.35mm)
6.25” (158.8mm)
1.25”
(31.8mm)
0.85” (21.6mm)
0.5625” (14.3mm)
2.415” (61.3mm)
0.685” (17.4mm)
1.77”
(45mm)
0.885” (22.5mm)
1.125” (28.3mm)
Knockouts
2.00” (50.8mm) 2.00” (50.8mm)
Altronix is not responsible for any typographical errors. Product specifications are subject to change without notice.
––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
website: www.altronix.com | e-mail: [email protected] | Lifetime Warranty
IIT2M7LXKV Kit Series G06W MEMBER
/