Focal Point Lia DLIA Installation guide

Category
Rack accessories
Type
Installation guide
©2023 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
1 of 5
IS0831 REV. B
LiaTM
DLIA-36S|48S|60S-CRV1
Luminaires must be installed by a qualified
electrician (check with local and national
codes for proper installation).
To prevent electrical shock, disconnect
electrical supply before installation or
servicing.
Contractor is responsible for adequately
reinforcing walls and/or ceilings to support
fixture weight.
Focal Point, LLC accepts no responsibility
for inadequately reinforced walls and/or
ceilings.
The information contained in this drawing
is the sole property of Focal Point, LLC. Any
reproduction in part or whole without the
written permission of Focal Point, LLC is
prohibited.
POWER OFF
POWER ON
ATTENTION
SEE ADDITIONAL
INSTRUCTIONS
BEFORE YOU BEGIN COMPONENT KEY
INSTRUCTION KEY Stem Mount
Cable Mount
Shade Segment
36" unit x 2 segments
48" unit x 3 segments
60" unit x 4 segments
Joiner
36" unit x 2
48" unit x 3
60" unit x 4
PET Installation Template
LIGHT ENGINE PET SHADE
CABLE MOUNT INSTALLATION
SEE PAGE 2
STEM MOUNT INSTALLATION
SEE PAGE 3
PET SHADE INSTALLATION
SEE PAGE 4
LIGHT ENGINE MUST BE INSTALLED
PRIOR TO PET SHADE
Joiner Screw
(700295)
2 of 5
IS0831 REV. B ©2023 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
6
4
11
3
11
5
BY
OTHERS
MAKE ELECTRICAL CONNECTION
2
DEPRESS PLUNGER
WHILE SUPPORTING
LUMINAIRE
” MINIMUM
TRIM EXCESS CABLE AT ADJUSTER END
DO NOT SUSPENDED DIRECTLY FROM JBOX
BRACKET MUST BE SECURED INDEPENDENTLY
TO STRUCTURE ABOVE TO SUPPORT AT MINIMUM
THE WEIGHT OF THE FIXTURE SEE PAGE 
SECURE
BRACKET TO
STRUCTURE
ABOVE
SET SUSPENSION CABLE
TO DESIRED LENGTH
1
CABLE MOUNT
INSTALL JBOX BY OTHERS AND RODS BY OTHERS
SECURE RODS TO STRUCTURE ABOVE
LIGHT ENGINE INSTALLATION
WEIGHTS:
" UNIT   LBS
 PEOPLE RECOMMENDED
FOR INSTALLATION
" UNIT   LBS
 PEOPLE RECOMMENDED
FOR INSTALLATION
" UNIT   LBS
 PEOPLE RECOMMENDED
FOR INSTALLATION
3 of 5
IS0831 REV. B ©2023 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
BY
OTHERS
MAKE ELECTRICAL CONNECTION
3
. ATTACH THE STEM TO COVER. DO NOT
OVER TIGHTEN STEM, THIS MAY CAUSE
PINCHED WIRES.
. USING PLIERS, SECURELY TIGHTEN
LOCK NUT. STEM MUST BE SECURELY
TIGHTENED AND UNABLE TO SPIN LOOSE.
45
18”
10.375”
120˚
7.5”
13”
120˚
STEM MOUNT
1
12.375”
17.5”
90˚
1
2
1
2
2
' DIAMETER ' DIAMETER ' DIAMETER
4 of 5
IS0831 REV. B ©2023 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
TIGHT FIT, MULTIPLE PEOPLE
REQUIRED FOR REMOVAL
AVOID ALL CONTACT WITH LED
SURFACE, LEDs ARE EASILY DAMAGED
DRIVER SERVICE
32
1
EMERGENCY
SEE BATTERY MANUFACTURER
INSTRUCTIONS
EMERGENCY MAXIMUM MOUNTING HEIGHT:
.'
PET SHADE INSTALLATION
BA
UNFOLD PET
INSTALLATION TEMPLATE
" UNIT ONLY STEM MOUNT ONLY
REMOVE CENTER INSERT FOR
STEM MOUNT INSTALLATION ONLY
" UNIT " UNIT " UNIT
1
ALIGN INNER CUTOUT OF TEMPLATE WITH SUSPENSION POINTS
TEM MOUNT SKYDOME
48B
TEMPLATE INSTALLS
PRINT SIDE DOWN
5 of 5
IS0831 REV. B ©2023 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
45
ENSURE
MAGNETS ARE
FULLY SEATED
WITHIN
DESIGNATED
SLOTS INSTALL
REMAINING
SHADE
SEGMENTS
6
INSTALL JOINER
BETWEEN SHADE
SEGMENTS
7 8
INSTALL REMAINING JOINERS
X
211
3
ALIGN EDGE OF
SHADE SEGMENT
WITH STARTING
NOTCH ON
TEMPLATE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5

Focal Point Lia DLIA Installation guide

Category
Rack accessories
Type
Installation guide