Arkray Glucocard Vital User Instruction Manual

Category
Measuring, testing & control
Type
User Instruction Manual

Arkray Glucocard Vital is a blood glucose monitoring system that provides accurate and reliable blood sugar readings to help manage diabetes. With its advanced features, it offers ease of use and helps track blood glucose levels effectively:

  • Fast and Accurate Results: Get blood sugar readings in just 5 seconds with high accuracy.

  • Small Blood Sample: Requires only a tiny blood sample of 0.5 microliters, minimizing discomfort.

  • Alternative Site Testing: Allows testing from alternate sites like the palm or forearm for added convenience.

  • Easy-to-Use Interface: Features a large, clear display and simple buttons for intuitive operation.

Arkray Glucocard Vital is a blood glucose monitoring system that provides accurate and reliable blood sugar readings to help manage diabetes. With its advanced features, it offers ease of use and helps track blood glucose levels effectively:

  • Fast and Accurate Results: Get blood sugar readings in just 5 seconds with high accuracy.

  • Small Blood Sample: Requires only a tiny blood sample of 0.5 microliters, minimizing discomfort.

  • Alternative Site Testing: Allows testing from alternate sites like the palm or forearm for added convenience.

  • Easy-to-Use Interface: Features a large, clear display and simple buttons for intuitive operation.

User Instruction Manual Read this User Instruction Manual carefully
before you start testing.
2
CAUTION:
Before using any product to test your blood sugar (blood glucose),
read all instructions and practice the test. Do all quality control checks
as directed and consult with a diabetes healthcare professional. These
recommendations apply to all blood glucose monitoring systems and
are supported by the American Association of Diabetes Educators, the
American Diabetes Association, the U.S. Food and Drug Administration,
and the Health Industry Manufacturers Association.
3
Introduction. . ................................................6
Intended Use. .............................................7
Important Information. ......................................8
The GLUCOCARD® Vital™ Blood Glucose Monitoring System ...........9
Understanding the GLUCOCARD® Vital™ Blood Glucose Meter ........10
Explanation of the Full Display Screen .........................11
GLUCOCARD® Vital™ Test Strips. ................................12
Testing with GLUCOCARD® Vital™ Test Strips. ......................13
Important Test Strip Information ..............................14
Changing the Battery ......................................15
Meter Set Up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Setting the Time and Date ..................................18
Using Assure® Dose Control Solution .............................22
Recommended Use of Control Solution ........................23
Performing a Control Solution Test ............................24
Comparing Control Solution Results ..........................28
TABLE OF CONTENTS
4
Blood Glucose Testing .........................................30
Obtaining a Drop of Blood ..................................30
Performing a Blood Glucose Test ................................33
Alternate Site Testing (AST) .....................................36
Important Information About Alternate Site Testing (AST) ..........36
Preparing to Test Your Blood Glucose From an Alternate Site .......38
Performing a Blood Glucose Test From an Alternate Site ...........39
Downloading Test Results to a Computer ..........................43
Understanding Test Results .....................................44
Comparing Meter and Laboratory Results ......................44
Expected Blood Glucose Readings ............................47
High Blood Glucose Readings ...............................47
Low Blood Glucose Readings ................................48
Diabetes Findings .........................................48
Meter Memory ..............................................51
Marking Results in the Memory . .............................51
Marking Control Solution Tests ...............................51
Marking Other Results .....................................52
Recalling Results. .........................................52
5
Display Screen Images ........................................56
Caring For Your GLUCOCARD® Vital™ Blood Glucose Meter ...........60
Cleaning the Meter ........................................60
Storage .................................................60
Specications ...............................................62
Warnings, Precautions, and Limitations ...........................63
Warranty. . . .................................................65
The GLUCOCARD® Vital™ Blood Glucose Meter .................65
6
INTRODUCTION
Thank you for choosing the GLUCOCARD® Vital™ Blood Glucose Monitoring
System. Frequent blood glucose testing is important. It tells you how your
diabetes is affected by factors such as medication, diet, exercise, and stress
management. Blood glucose test results can also tell you if your diabetes
is changing in ways that affect your treatment plan. Always consult your
diabetes healthcare professional before making any changes. All of the
information needed to use the GLUCOCARD® Vital™ System is included in
this manual. Please read it thoroughly before using the system. If you have
any questions, call ARKRAY Customer Service at 800.566.8558, 24 hours
a day, 7 days a week, USA and Canada only. Contact your healthcare
professional with questions if you are unable to reach Customer Service.
7
Intended Use
The GLUCOCARD® Vital™ Blood Glucose Monitoring System is intended
for the quantitative measurement of glucose in fresh capillary whole blood
samples drawn from the ngertips or palm. Testing is done outside the
body (
In Vitro
Diagnostic Use). It is indicated for use at home (over the
counter [OTC]) by persons with diabetes, or in clinical settings by healthcare
professionals, as an aid to monitor the effectiveness of diabetes control. It is
not intended for the diagnosis of or screening for Diabetes Mellitus, and is not
intended for use on neonates.
8
Important Information
• Test results below 70 mg/dL indicate low blood glucose (hypoglycemia).
• Test results above 240 mg/dL indicate high blood glucose (hyperglycemia).
• If results are below 70 mg/dL or above 240 mg/dL, repeat the test.
If results continue to measure below 70 mg/dL or above 240 mg/dL consult
your diabetes healthcare professional immediately.
If symptoms are not consistent with test results AND all the instructions
have been followed carefully, contact your diabetes healthcare professional.
Before testing, always make sure both the meter and test strips are at
operating temperature.
9
The GLUCOCARD® Vital™ System Includes:
• GLUCOCARD® Vital™ Meter
• Carrying Case
• User Instruction Manual
• Self-Testing Logbook
May include Test Strips, Control Solution, and Lancing Device and/or Lancets
THE GLUCOCARD® VITAL™ SYSTEM
10
FRONT BACK
Display Screen
Back Button
On/Off Button
Forward Button
Battery
Compartment
Cover
Test Strip Port
UNDERSTANDING THE GLUCOCARD® VITAL™ BLOOD GLUCOSE METER
Data
Connection
Port
11
Explanation of the Full Display Screen
Time
Date
Average Test
Reading
Control
Solution Test
Low
Battery
Unit of
Measurement
Temperature
Warning
Test Strip
Apply Blood
Insert/Remove
Test Strip
Memory Mode
Error Code
Result Warning
Main Display:
Test Strip Code
Test Countdown
Test Results
Error Codes
If any part of the display screen is missing when the meter is turned on,
call Customer Service at 800.566.8558.
12
These capillary action test strips require only
0.5 µL of blood and provide an end-ll sample
application tip for easy blood application.
The GLUCOCARD® Vital™ Blood Glucose
Monitoring System measures the amount
of glucose (sugar) in fresh capillary whole
blood. When a drop of blood is added to the
sample application tip, the sample is drawn
into the test strip reaction site. The glucose
in the blood reacts with the enzyme on the
test strip. This reaction produces a current,
proportional to the amount of glucose in the
blood. The meter detects the current and
converts it into a blood glucose reading.
TEST STRIP
Reaction
Site
Test Strip
Contact Bars
GLUCOCARD® VITAL™ TEST STRIPS
Sample Application Tip
(apply blood to end of test strip
and capillary action will pull blood
to reaction site quickly and easily)
13
Important Test Strip Information
Store the test strip bottle in a cool, dry place between 39°F–86°F
(4°C–30°C).
• Keep away from direct sunlight and heat.
• Do not refrigerate or freeze.
• Do not store or transfer the test strips outside the original bottle.
As soon as you have removed a test strip, replace the cap securely on
the bottle.
Use test strips within 90 days (3 months) of opening and not beyond the
expiration date (
).
The GLUCOCARD® Vital™ Blood Glucose Monitoring System works
with the GLUCOCARD® Vital™ Blood Glucose Test Strips.
TESTING WITH GLUCOCARD® VITAL™ TEST STRIPS
14
Important Test Strip Information
Write the date of opening on the bottle label to remind you to discard the
test strips after 90 days (3 months).
• Do not bend, cut, or alter a test strip.
• Do not reuse a test strip.
Use only GLUCOCARD® Vital™ test strips with the GLUCOCARD® Vital™
meter.
• Ensure your hands are clean and dry before handling test strips.
15
NOTE:
Changing the battery should only take a few seconds. If the battery is
changed within 30 seconds, the meter memory is not affected. You will not
lose any past test results and the settings are not affected. However, if it
takes longer than 30 seconds to change the battery, or if the battery is dead
before changing it, the time and date settings may need to be reset.
The rst time the meter is turned on after changing the battery, you may see
a display screen message (E00). This means you should check that the time
and date are correct. See pages 18–21 for detailed instructions on changing
the time and date.
Changing the Battery
The GLUCOCARD® Vital™ blood glucose meter has a CR2032 battery installed.
16
When the battery power is getting low, your meter shows . You have enough
power for about 100 tests before you need to replace the battery.
If the is ashing, there is only enough power for about 20 tests. Replace the
battery as soon as possible.
When the battery has run out, the meter will not work. CR2032
3V
+
WARNING:
Keep all batteries out of children’s reach. If a battery is swallowed, consult a
doctor immediately.
Battery
17
How to Change the Battery
Step 1
Turn the meter off. The battery cover is on the back of the meter.
Step 2
Pull the battery cover up with your nger or ngernail. Remove battery cover.
Step 3
Remove the old battery. If necessary, turn the meter over and tap it gently
against the palm of your hand until the battery falls out. Avoid the use of
sharp objects that may damage the meter.
Step 4
Insert the new battery. The “+” on the battery should be facing up.
Step 5
Replace the battery cover.
18
Meter Set Up
Before using the GLUCOCARD® Vital™ meter for the rst time, you must set
the time and date. You can choose between the 12-hour format (1–12 o’clock
with a.m. or p.m.) and the Military 24-hour format (0–23). The date format can
either be displayed as month/day (USA format) or day/month (International
format). Do not perform a blood glucose test until you have set the meter
correctly.
Setting the Time and Date
Step 1: Turn on meter
Press the On/Off button to turn the meter on. The full screen appears briey. If
any part of the display screen is missing (see page 11), call Customer Service.
The meter then displays the time, date, unit of measurement, and the insert
test strip symbol.
Step 2: Enter set-up mode
Press and hold down the On/Off button for more than 2 seconds to enter the
set-up mode.
19
Step 3: Set the time format
The time can be displayed in either a 24-hour format
or 12-hour format with a.m. and p.m. The meter
displays the current time format. To change format,
press either the Back or Forward button. Press the
On/Off button to select the time format. The date
format then appears on the display.
Month/Day
Format
Day/Month
Format
Step 4: Set the date format
The date format can either be displayed as month/
day (01/31) or day/month (31/01). The meter displays
the current format. To change format, press either the
Back or Forward button. Press the On/Off button to
select the date format. The hour setting then ashes
on the display.
20
Step 5: Set the hour
Press and release the Back or Forward button to change the hour.
Hold the Back or Forward button down to scroll through quickly.
When the correct hour is displayed, press the On/Off button. The
minute setting then ashes on the display.
Step 6: Set the minute
Press and release the Back or Forward button until the correct
minute appears. Hold the Back or Forward button down to
scroll through quickly. When the correct minute is displayed,
press the On/Off button. The month setting then ashes on the
display.
Step 7: Set the month
(If day/month format is selected then Step 7 will set day)
Press and release the Back or Forward button until the correct
month appears. Hold the Back or Forward button down to scroll
through quickly. When the correct month is displayed, press
the On/Off button. The day setting then ashes on the display.
Hour ashing
Minute ashing
Month ashing
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68

Arkray Glucocard Vital User Instruction Manual

Category
Measuring, testing & control
Type
User Instruction Manual

Arkray Glucocard Vital is a blood glucose monitoring system that provides accurate and reliable blood sugar readings to help manage diabetes. With its advanced features, it offers ease of use and helps track blood glucose levels effectively:

  • Fast and Accurate Results: Get blood sugar readings in just 5 seconds with high accuracy.

  • Small Blood Sample: Requires only a tiny blood sample of 0.5 microliters, minimizing discomfort.

  • Alternative Site Testing: Allows testing from alternate sites like the palm or forearm for added convenience.

  • Easy-to-Use Interface: Features a large, clear display and simple buttons for intuitive operation.

Ask a question and I''ll find the answer in the document