ReliOn Prime User Instruction Manual

Category
Measuring, testing & control
Type
User Instruction Manual
Prime
Blood Glucose Monitoring System
User
Instruction
Manual
2
CAUTION:
Before using any product to test your blood sugar (blood
glucose), read all instructions and practice the test. Do all
quality control checks as directed and consult with a diabetes
healthcare professional. These recommendations apply to all
blood glucose monitoring systems and are supported by the
American Association of Diabetes Educators, the American
Diabetes Association, the U.S. Food and Drug Administration,
and the Health Industry Manufacturers Association.
3
Introduction ...........................................6
Intended Use .......................................7
Important Information .................................8
The ReliOn® Prime System ................................9
Understanding the ReliOn® Prime Blood Glucose Meter ........10
Explanation of the Full Display Screen ...................11
ReliOn® Prime Test Strips ................................12
Testing with ReliOn® Prime test strips .......................13
Important Test Strip Information ........................14
Changing the Battery ................................15
Meter Set Up .......................................18
Setting the Time and Date ............................18
Blood Glucose Testing ...................................22
ReliOn® Lancing Device ...............................22
Obtaining a Drop of Blood ............................25
Performing a Blood Glucose Test ..........................27
TABLE OF CONTENTS
4
Alternate Site Testing (AST) ...............................31
Important Information About AST ....................... 31
Preparing to Test Your Blood Glucose From an Alternate Site .......33
Performing a Blood Glucose Test From an Alternate Site .....34
Using Control Solution ..................................39
Recommended Use of Control Solution ..................40
Performing a Control Solution Test ......................41
Comparing Control Solution Results .....................45
Downloading Test Results to a Computer ....................46
Understanding Test Results ............................... 47
Comparing Meter and Laboratory Results ...............47
Expected Blood Glucose Readings .....................50
High Blood Glucose Readings .........................50
Low Blood Glucose Readings .........................51
Diabetes Findings ..................................51
Meter Memory ........................................54
5
Marking Results in the Memory ........................54
Marking Control Solution Tests .........................54
Marking Other Results. ...............................55
Recalling Results ....................................55
Display Screen Images ..................................59
Caring For Your ReliOn® Prime Blood Glucose Meter ...........64
Cleaning the Meter ..................................64
Storage. ...........................................64
Specifications .........................................66
Warnings, Precautions, and Limitations .....................67
Warranty. .............................................69
6
INTRODUCTION
Thank you for choosing the ReliOn® Prime Blood Glucose Monitoring
System. Frequent blood glucose testing is important. It tells you how your
diabetes is affected by factors such as medication, diet, exercise, and stress
management. Blood glucose test results can also tell you if your diabetes
is changing in ways that affect your treatment plan. Always consult your
diabetes healthcare professional before making any changes. All of the
information needed to use the ReliOn® Prime System is included in this
manual. Please read it thoroughly before using the system. If you have any
questions, call Customer Service at 800.631.0076 (24 hours a day, 7 days a
week). Contact your healthcare professional with questions if you are unable
to reach Customer Service.
7
Intended Use
The ReliOn® Prime Blood Glucose Monitoring System is intended for the
quantitative measurement of glucose in fresh capillary whole blood samples
drawn from the fingertips or palm. Testing is done outside the body (
In Vitro
Diagnostic Use). It is indicated for use at home (over the counter [OTC]) by
persons with diabetes, or in clinical settings by healthcare professionals, as an
aid to monitor the effectiveness of diabetes control. It is not intended for the
diagnosis of or screening for Diabetes Mellitus, and is not intended for use on
neonates.
8
Important Information
 
 
glucose (hyperglycemia)
 
 
consult your diabetes healthcare professional immediately
 
have been followed carefully, contact your diabetes healthcare
professional
 
operating temperature
9
The ReliOn® Prime System Includes:
 
 
 
 



THE ReliOn® Prime SYSTEM
10
Back
Battery Compartment
Cover
UNDERSTANDING THE ReliOn® Prime BLOOD GLUCOSE METER
Front
Display Screen
Back Button

Forward Button
Test Strip Port
Data
Connection
Port
11
Explanation of the Full Display Screen
Time
Date
Average Test
Reading
Control
Solution Test
Low
Battery
Unit of
Measurement
Temperature
Warning
Test Strip
Apply Blood

Test Strip
Memory Mode
Error Code
Result Warning

Test Countdown
Test Results
Error Codes
If any part of the display screen is missing when the meter is turned on call
Customer Service at 800.631.0076.
12
These capillary action test strips require
only 0.5 micro-liter (µl) of blood and provide
an end-fill sample application tip for easy
blood application. The ReliOn® Prime Blood
Glucose Monitoring System measures the
amount of glucose (sugar) in fresh capillary
whole blood. When a drop of blood is added
to the sample application tip, the sample is
drawn into the test strip reaction site. The
glucose in the blood reacts with the enzyme
on the test strip. This reaction produces
a current, proportional to the amount of
glucose in the blood. The meter detects the
current and converts it into a blood glucose
reading.
TEST STRIP
Reaction
Site
Test Strip
Contact Bars
Sample Application Tip
(apply blood to end of test strip
and capillary action will pull blood
to reaction site quickly and easily)
ReliOn® Prime TEST STRIPS
13
Important Test Strip Information
 

 
 
 
 
bottle
 
expiration date ( )
The ReliOn® Prime Blood Glucose Monitoring System works with
the ReliOn® Prime Test Strips.
TESTING WITH ReliOn® Prime TEST STRIPS
14
Important Test Strip Information
 
strips after 90 days (3 months)
 
 
 
 
15
Note:
Changing the battery should only take a few seconds. If the battery is
changed within 30 seconds, the meter memory is not affected. You will not
lose any past test results and the settings are not affected.
However, if it takes longer than 30 seconds to change the battery, or if the
battery is dead before changing it, the time and date settings may need to
be reset.
The first time the meter is turned on after changing the battery, you may see
a display screen message (E00). This means you should check that the time
and date are correct. (See pages 18-21 for detailed instructions on changing
the time and date).
Changing the Battery
The ReliOn® Prime Blood Glucose Meter has a CR2032 battery installed.
16
When the battery power is getting low, your meter shows . You have
enough power for about 100 tests before you need to replace the battery.
If the is flashing, there is only enough power for about 20 tests. Replace the
battery as soon as possible.
When the battery has run out, the meter will not work.
CR 2032
Li-Mn 3V
+
WARNING:

doctor immediately.
17
How to Change the Battery
Step 1
Turn the meter off. The battery cover is on the back of the meter.
Step 2
Pull the battery cover up with your finger or fingernail. Remove battery cover.
Step 3
Remove the old battery. If necessary, turn the meter over and tap it gently
against the palm of your hand until the battery falls out. Avoid the use of
sharp objects that may damage the meter.
Step 4
Insert the new battery. The “+” on the battery should be facing up.
Step 5
Replace the battery cover.
18
Meter Set Up
Before using the ReliOn® Prime Meter for the first time, you must set the time

or pm) and the Military 24-hour format (0-23). The date format can either be

Do not perform a blood glucose test until you have set the meter correctly.
Setting the Time and Date
Step 1: Turn on meter

any part of the display screen is missing (see page 11), call Customer Service.
The meter then displays the time, date, unit of measurement, and the insert
test strip symbol.
Step 2: Enter set-up mode

set-up mode.
19
Step 3: Set the time format
The time can be displayed in either 24-hour format or
12-hour format with AM and PM. The meter displays
the current time format. To change format, press

button to select the time format. The date format then
appears on the display.


Step 4: Set the date format


the current format. To change format, press either the

select the date format. The hour setting then flashes
on the display.
20
Step 5: Set the hour
Press and release the Back or Forward button to change the hour.
Hold the Back or Forward button down to scroll through quickly.

minute setting then flashes on the display.
Step 6: Set the minute
Press and release the Back or Forward button until the correct
minute appears. Hold the Back or Forward button down to
scroll through quickly. When the correct minute is displayed,

display.
Step 7: Set the month (If day/month format is selected then
Step 7 will set day)
Press and release the Back or Forward button until the correct
month appears. Hold the Back or Forward button down to scroll
through quickly. When the correct month is displayed, press

Hour flashing
Minute flashing
Month flashing
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70

ReliOn Prime User Instruction Manual

Category
Measuring, testing & control
Type
User Instruction Manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI