Midmark 6271 - 6276 (Wall Mounted Units) offers a flexible and ergonomic solution for various medical environments. Its height-adjustable column allows users to customize their workspace, promoting comfort and reducing strain. The unit's sturdy construction and secure wall-mounting ensure stability and safety. With its cable management system, the unit keeps cords organized and out of the way, maintaining a clean and efficient workspace. The Mouse House attachment provides convenient placement for the mouse, enhancing user comfort and productivity.

Midmark 6271 - 6276 (Wall Mounted Units) offers a flexible and ergonomic solution for various medical environments. Its height-adjustable column allows users to customize their workspace, promoting comfort and reducing strain. The unit's sturdy construction and secure wall-mounting ensure stability and safety. With its cable management system, the unit keeps cords organized and out of the way, maintaining a clean and efficient workspace. The Mouse House attachment provides convenient placement for the mouse, enhancing user comfort and productivity.

Attention!
For OSHPD Regulated Installations, please go to
www.midmark.com to download the appropriate
OSHPD Approval and Installation documents.
6276-001 Installation Instructions
INS-6276-001 (Rev. D)
Mounting Template/Drilling Hole Preparation:
Tools required:
Electric Drill with driver extension
1/2” Drill Bit
Phillips head screwdriver/bit
Punch
Parts Included:
(1) Mounting Template
Parts Included Cont.:
(1) Keyboard Platform Assembly
(1) Keyboard Pivot Housing
(1) Height Adjustable Column Assembly
(6) Hilti Snaptoggle Heavy-Duty Toggle Bolts (2 extra)
(4) 1/4-20 x 3” Long Phillips Drive Pan Head Machine Screws
(4) 1/4-20 x 1 1/4” Long Phillips Drive Pan Head Machine Screws
(4) M4-0.7 x 10mm Long Phillips Drive Flat Head Machine Screws
(8) Dual Lock Velcro Squares
(1) Mouse House
1
2
Installation Hardware
Fig. B
Fig. A
Use these
four holes
for this
installation.
Toggler Bolt Installation Instructions:
a. Place mounting template on wall (See FIG.A).
Note: Place bottom line of template
on fl oor. This will position Input for a
working range of 29” - 47” height range.
b. Compare level to line printed on template
to ensure mounting template is perfectly level
(See FIG. B).
c. Use punch to locate holes in wall as
marked on template.
d. Make sure that drill bit point is centered
with cross-pattern of hole location.
b.
c.
a.
Drill 1/2” size hole. Hold metal channel
at alongside plastic straps and slide
channel through the hole. Minimum
clearance beind wall: only 1 7/8”
Hold ends of straps together between thumb
& forefi nger and pull toward you until channel
rests behind wall. Rachet cap along straps
with other hand until fl ange of cap is
ush with wall.
Place thumb between straps at wall. Push
thumb side to side, snapping off straps level
with fl ange of cap.
(1/2” Hole)
6276-001 Installation Instructions
INS-6276-001 (Rev. D)
Midmark Corporation | 60 Vista Drive | PO Box 286 | Versailles, Ohio 45380-0286 | USA | midmark.com
Caution
Properinstallationoftoggleboltsrequired
toprovidesecurewallmounting.Minimum
drywallthicknesstobe½”.
3
Product Assembly Instructions:
a. Attach Pivot Keyboard Assembly to
Column Assembly by securing with
(4) 1/4-20 x 1 1/4” Long Phillips Drive
Pan Head Machine Screws and
(4) 1/4” Flat Washers
4
6276-001 Installation Instructions
INS-6276-001 (Rev. D)
Midmark Corporation | 60 Vista Drive | PO Box 286 | Versailles, Ohio 45380-0286 | USA | midmark.com
Prior to installing height
adjustable column assembly
to wall, attach column
mounted accessory
(if applicable)!
a. Do Not unfasten Safety Strap from
adjustment lever (See FIG. A)
b.Align four column assembly mounting holes
with holes in wall. Secure with
(4) 1/4-20 x 3” previously installed
toggler fasteners (See FIG. B). NOTE:
SECURE BOTTOM TWO FASTENERS FIRST
(See Fig. C)
c. Unfasten Safety Strap from adjustment lever.
FIG. A
FIG. B
FIG. C
Height
Adjustment
Column
Assembly
Wall Installation:
5
7
6
To attach the Keyboard Platform assembly to
the Keyboard Pivot Housing assembly, slide
out guide plate from keyboard platform.
Attach Keyboard Platform assembly to
Keyboard Pivot Housing assembly by securing
with (4) #10-24 x 1/2” Long Phillips Drive Flat
Head Machine Screws.
There are two different suggested mounting
positions for the Mouse House, they are
as follows:
a. On wall (make sure to check this when assembly
is adjusted to its highest position) (See FIG.A).
b. Underneath small worksurface (See FIG. B).
FIG. B
FIG. A
FIG. A
Lower Cable Management: For CPU’s,
keyboard and mouse:
Run the tech-fl ex covered cables through the
back of the height adjustable column assembly
(See FIG. A).
Lower Cable Management:
Mouse House Attachment:
6276-001 Installation Instructions
INS-6276-001 (Rev. D)
Midmark Corporation | 60 Vista Drive | PO Box 286 | Versailles, Ohio 45380-0286 | USA | midmark.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Midmark 6271 - 6276 (Wall Mounted Units) Installation guide

Category
Keyboards
Type
Installation guide

Midmark 6271 - 6276 (Wall Mounted Units) offers a flexible and ergonomic solution for various medical environments. Its height-adjustable column allows users to customize their workspace, promoting comfort and reducing strain. The unit's sturdy construction and secure wall-mounting ensure stability and safety. With its cable management system, the unit keeps cords organized and out of the way, maintaining a clean and efficient workspace. The Mouse House attachment provides convenient placement for the mouse, enhancing user comfort and productivity.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI