Ditel Dynamic 3 User manual

Type
User manual
0
Dynamic Manual 3
Software user manual
Dynamic 3
Date: 14/07/2016
1
Dynamic Manual 3
INDEX
1. INTRODUCTION ............................................................................... 2
1.1. Minimum PC configuration ..................................................... 2
1.2. Instalation of software Dynamic 3 .......................................... 2
2. MAIN MENU TOP ............................................................................. 4
3. COMMUNICATION CONNECTING THE DEVICE ................................... 5
3.1. Connection type ...................................................................... 5
3.2. Search for device ..................................................................... 5
4. EDITION ............................................................................................ 6
4.1. Program menu ......................................................................... 6
4.2. Page explorer ........................................................................... 7
4.3. Editing lignes ............................................................................ 7
4.4. Line and page properties .......................................................... 8
4.5. Actions menu ........................................................................... 9
4.5.1. Fonts ..................................................................................... 9
4.5.2. Modes .................................................................................. 10
4.5.3. Graphis ................................................................................. 10
4.5.4. tokens .................................................................................. 11
5. PROGRAMS ..................................................................................... 12
6. TIME DISPLAY .................................................................................. 14
7. DISPLAY CONFIGURATION ............................................................... 15
8. APLICATION SETTINGS...................................................................... 15
9. FONTS ANS GRAPHICS EDITOR ......................................................... 16
9.1. Fonts editor ............................................................................ 16
9.2. Graphics editor ....................................................................... 18
2
Dynamic Manual 3
1. INTRODUCTION
Dynamic 3 is software for managing and editing LED screens Their content. Developed entirely by DITEL. Among ITS
main features are:
- Compatible with Windows XP, 7, 8 and 10.
- Allows It to Work With Simultaneously Several panels.
- Easy and intuitive.
- Editing graphics, fonts.
- Simulator
- Free dowload.
- Free license updates.
- Mercury LED System.
1.1 Minimum PC configuration
The minimum PC requirements are:
- Windows XP operating system or later.
- Microsoft.NET Framework 4.0.
- Minimum resolution of 1280 x 720 screen.
1.2 Installing the Dynamic 3 software
To install the program we must run Setup.exe ((you can download the software on our website) and follow the
program instructions below Explained:
Step 1: September 2:
Run Setup.exe and click Next. Set the folder Where the files are installed. Default
folder is "C: \ Program Files (x86) \ DITEL \ Dynamic 3
\".
3
Dynamic Manual 3
Step 3: Step 4:
Instalation confirm. InstalDynamic ling 3.
Step 5:
Finish the installation.
These eleven steps are completed, the Dynamic will be 3 software ready to work. Remember to update Windows
Microsoft.NET Framework 4.0 to Obtain or later.
4
Dynamic Manual 3
2. MAIN MENU TOP
The main menu of the software Consist of:
- Edition: Here we will edit the texts and graphics That will Appear on the LED screen.
- Programs: In this section we can manage the programs created for the LED screen, as well as our playlist.
- display Time: In This tab we can send the date and time of our PC to the device, Obtain the device time or
introduces a time and date manually. It Also Allows to Work With the 25 variables internal.
- display Configuration:Here we can configure the multiple options of the device,: such as brightness, the
address of the device, the Ethernet settings, Among other parameters. (Only for advanced users).
- Application Settings:Here we can set the program options. For example, the language, the default model,
the values of the default edition.
- font Editor:In this section we can manage, modify and create new fonts and graphics for our screens.
(Predesigned fonts and graphics are included).
- Communication:In This tab we can choose in Which mode we want to connect the device to our
computer. It can be by USB, RS232 / RS485 or Ethernet.
3. COMMUNICATION - CONNECTING THE DEVICE
PROGRAMS EDITION DISP. TIME DISP. CONFIG. APPLI.CONFIG FONT EDITOR COMMUNICATION
5
Dynamic Manual 3
To Work With any of our displays, first it is Necessary to connect to our device, so we go to the "communications"
section of the top menu.
3.1 Connection type
To begin With, We Have to select the type of connection we are going to use to connect to our screens. There are
three types of connection:
USB RS232 / RS485 Ethernet
To connect via Ethernet we must enter the IP address of our device.
The default IP address is 192.168.1.100 and the TCP port 53.
If We Have More Than One LED Display we can select a range of IP in Which to search the devices.
3.2 Searching device
Once communication parameters correctly selected Have Been, We Have to press the "Search" button. It appears it
by searching one device (or more) into the list below. Then add the device found to our devices list pressing "Add to
devices File" while if we want to replace, pressing "Replace device files". The list of devices is stored in a file on our
PC.
Important:On Error in communication, we can select communication mode or Slow Increase
values in advanced settings: such as detailed below:
Display Timeout response and displays Search Timeout: + 1.00.
TCP Socket Timeout and TCP Socket Delay: + 0.05.
On USB communication check the USB driver are installed well. USB drivers can be download from our web page.
On serial communication, Baud, Data Bits, Parity and Stop Bits are by default 9600, 8, N and 1 respectively.
4. EDITION
These are the different parts That Make up the Dynamic 3 Editing program.
6
Dynamic Manual 3
Next we will see in detail each one of them.
4.1 Program menu
1 New: Create a new program to the system configuration ACCORDING and the default values. A new
program is generated Automatically When Dynamic 3 is opened.
1. Open: Opens an existing program in the PC's C: \ Users \ Username \ Documents \ MP Files directory.
2. Save: Keep changes made on the Previously opened program.
3. Save as: Creates a ".hgp" backup file of the new program in the PC's C: \ Users \ Username \ Documents \
MP Files directory.
4. EXECUTE: Sends the program to display the selected device in the list for immediate execution. The
program is stored in the display under the default name - FASTEXEC--.
5. Stop Display:Stops the program execution of the selected display in the device list. No LED is lit in the
display Then Which remains in a state of waiting.
5. Actions Menu
4. Line and Page Properties
2. Page Explorer
3. Editing Lines
7
Dynamic Manual 3
6. Save and Execute: Sends the program to display the selected device in the list for immediate execution and
a copy of the program is saved in the display memory under the name of the program defined by the user.
ATTENTION: The program name stored in the display must have a maximum of 8 characters in uppercase.
This must be taken into account When recording programs on the PC. If the name of the program is greater
than 8 characters, it will be amputated when it is sent on the display Which May cause one program to be
overwritten by another Whose Name Begins with the same eight characters.
NOTE: If the display is disconnected, it will restart by executing the program or in stop mode to the
configuration of ACCORDING Reset the display at startup option (see menu configuration device)
Explorer 4.2 pages
The page explorer provides a global view of the new program or program selected and the ability to navigate
between pages as well as perform the following operations:
The icons can be found at the top of the browser pages are as follows respectively:
- New page Create a new blank page.
- New page by copying current Create a new page by copying the selected
- Erase page: Deletes the selected page.
- Move Up: Moves up to the selected page.
- Move Down: Move down to the selected page.
the execution of the Program will be done according to the order of the pages.
Options right mouse button on the page:
- Rename the page.
- Run the program from the selected page.
4.3 Editing lines
Simulator screen:
This part of the program is visualized what would later see in the LED display. Clicking the blank creates a new line.
We can create a maximum of 14 windows. To resize each window simply drag any of its corners.
We can manipulate each of the screens
Text Editing:
8
Dynamic Manual 3
Here we can write the same way as in the selected window the text you want or insert a graphic, time, time,
temperature ... Also the "tokens" and is reflected effects.
Manager lines:
Small menu that identifies the lines which shows the line number, delete one or all lines and maximize or minimize
the selected line.
4.4 Properties window
At the bottom of "Edit" find the line properties. Modify and view the properties of the current window or page.
Basically here we will control the times of the effects and characteristics of the window or page.
Current properties window:
- Source: It shows the current source and to modify the thickness thereof.
- Mode: It shows the selected effect and to modify its speed.
- Effects at the end: Effects at the end of the timeout.
Erased: Deletes the line so that it does not overlap with the next page.
Flash: Number of flashes.
- Justification text: Align text left, center or right.
Properties of the current page:
- Brightness:Set the brightness of the LEDs, you can select two options:
automatic: Brightness of the page established by the sensor screen.
Manual: You can set the brightness of the LEDs 1 to 100%.
9
Dynamic Manual 3
- Page Type: In case we have several windows created on the page, we can select between two types:
synchronized: All windows appear at the same time.
Independent: They are the windows of appearing in one, to complete the page.
Windows defined in current page:
It shows a list of all windows created on the current page. In the event that the selected page type this independent,
ie the windows one after another in succession, can modify their order of appearance and waiting times appear from
the end effect until it proceeds to the next window .
4.5 Menu actions
The actions menu is found on the left side of the screen. Within this menu options are detailed below:
- Sources.
- Modes.
- Graphics.
- Tokens.
4.5.1 Sources
Here we find the sources that we can choose and see the properties of the current line.
In case you want to use a larger font than the current window, we must first increase the
size of the window. The same would happen in case you want to use a smaller font than the
current window previously should resize the window.
Dynamic 3 features several predefined in various sizes, single color or multicolored fountains
sources.
Note: You can create custom in the "Editor Font" sources explained later.
4.5.2 modes
In this section we find different appearance modes available for windows. Among them
are the following:
- Righ now: The window appears immediately, ie without any effect.
- Run: The contents of the window scrolls from right to left.
- Go left: The contents of the window moves from left to right.
10
Dynamic Manual 3
- Go up: The contents of the window moves from bottom to top.
- Go down: The contents of the window moves up and down.
4.5.3 Graphics
In this section we find predefined graphics available in Dynamic 3. In the top section we
find a list with the different heights of graphics available.
To use such a graphic 16 pixels high, we need the current window count on the same
height.
Note: You can create custom charts in the "Editor Font" explained later.
4.5.4 Tokens
The "tokens" is a string that have a consistent meaning in a programming language, such
as for example the current date.
Data: In this section we can modify the appearance of text.
- Color: We must first select the text you want to modify in the section "Editing
Text", once selected, simply select a color.
11
Dynamic Manual 3
- Intermittent: If we click on this option will be added in "Editing Text" a small light bulb, which will make the
entire contents of the window is a flashing effect. If we want the effect only occurs on a few characters
without affecting others, we put the effect around them.
Time:Add date, time or temperature and the language appear. With page type "synchronized" you can only use a
language page. You just have to double-click on the you want to add, or, drag it to "Editing Text".
Events: Add a countdown to an event. To create it, select the event date on the calendar, give it a name and add to
the list.
You can select the remaining time by one unit.
Once created the event just have to double-click on the you want to add, or, drag it to "Editing Text".
variables:It is a quantity that can have any value and can change quickly. For example, the price of a product or the
parts count in a production line.
We can choose the ID variable, display or not the sign, alignment, length (number of characters), or decimal 0 or not
displaying the left.
The value of the variable is given in this section is only a sample value for the virtual screen we see in our PC. That is,
the value of the variable section does not change the actual value of the variable.
To change the value of the variable, we have to enter the "Clock" from the main menu. Once there we can change
the values of variables.
5. PROGRAMS
12
Dynamic Manual 3
From here you can edit the various programs stored on the computer, on the screen and join several programs as
cycles. To access the directory screen must "update directory".
1. Computer (first column): Default Dynamic 3 creates a folder named "MP Programs" in the "My Documents"
folder. It is simply a file browser for your PC.
2. Device (second column): In the Device column we can see all the programs that are inside the screen. With
the ability to execute them, stop them, delete and edit them.
Important: The name of the programs saved on the screen can not exceed 8 characters. For them it
is advisable not keep the programs on the PC with names longer than 8 characters.
3. Playlists (third column):Here we can see the lists created on the current screen. We may also execute them,
stop them, delete them, save them and create new lists.
Important: Programs to add to the lists, programs must be within the
device (screen).
In each of the added programs we see several options are as follows:
- Run by date:We can set the program start date and end date. The program will run only in this time
interval.
13
Dynamic Manual 3
- Run on time: We can set the program start time and end time. The program will run only in this time
interval.
- Remove program to finish execution: If you select this option, the program will disappear from the list
once their execution is complete.
- Select days of the week: We can set that day of the week you want the program to run.
All of these options can be combined in order to create automated without daily maintenance lists.
6. CLOCK
14
Dynamic Manual 3
1. Time and date: You can be configured in three ways:
o Regardless of the time and date of the device to the PC.
o Synchronize or export the time and date of the PC to the device.
o Set the time and date manually and send to the device.
2. Temperature: Obtainable temperature Cº device and manually add a difference.
(You can only be obtained in devices with temperature probe temperature).
3. Device Variables: You can change the values of 26 variables. To enter the value, we choose the letter of the
variable, type, add a description, the default and click "Send variable device value."
To view the value of variables stored in the device press "Get device variables value."
Note: The variables can only be used on certain devices.
7. DEVICE CONFIGURATION
On the top there are 3 buttons:
15
Dynamic Manual 3
Read Device Configuration: Obtains and saves the configuration of the device in the PC.
Save Device Configuration: all fields of the different tabs are saved on the device.
Restore Factory Settings: Restores factory settings.
When we read the different configuration tabs Depending on the device Appear in question. In This Manual
The fields for all devices are not detailled; for more information for device owners, consult the specific
manual.
For MOST of the devices, there are always two tabs That Appear (General and Advanced) plus another for
communications (Which VARY ACCORDING TO communications device).
"General" Tab
Language: Use by Times Tokens.
Power On Reset: If This option is selected the --FASTEXE-- file of Display memory will be cleared at each
powered on. The --FASTEXE-- file is used When the information is sent online from the software publisher
Dynamic3 or from a master device in integration mode (see communication protocols).
Low battery warning: If the battery level is low, the message "BATTERY" is showing few seconds When
the display is on powers.
"Communications" Tab
16
Dynamic Manual 3
Device Address: Indicates the device ID. This address must be unique for each device. The ID adresse
appears on the display as "A + ID" when it's powered on. The default address from factory is 01.
LocalCast Address: Address used to create groups. All the devices of a group must have the same
address.
timeout: Time in minutes at Which if the display does not receive data the program name "TIMEOUT"
stored in the display will be activated automatically.
The "TIMEOUT" program can display an error message or an empty communication program (with at Least
one space character) for the display remains black.
If time is 0 the function is disabled.
Protocols: Enable protocols.
RF Remote control code: Code of radio frequency remote control.
"Visual Option" Tab
With Clear Display: If the option "Never Clear" is selected, the execution of a new program is overlaid on
the previous program. The visual effect is only the different characters That change.
If the option "Command STOP" or "STOP Command or New Script" is selected, the display is cleared
STOP command on or before presenting a new program.
Dafault Mode Waiting Time, Speed, Width and Character Mode:
Program edition default settings If These parameters are not specified in the program sent to the display.
Otherwise it is the configuration of the program That has priority. (See current page properties and
communication protocols manuals)
"Brightness Control" Tab
17
Dynamic Manual 3
Minimum Brightness: The minimum percentage of intensity of LEDs When brightness is Set to Automatic.
Detected Maximum Brightness: The maximum percentage of luminosity detected by sensor. From here
the LED intensity is maximum.
default Brightness(%): The percentage of the intensity of LEDs in September is here. Also we can Set the
brightness to Automatic, so That the above percentage is disabled.
Brightness Sensor Filter: The Speed With Which We want to vary the brightness When Set to Automatic.
Doesn't change the sensibility of Brightness sensor.
Brightness Sensor:Enable the Brightness sensor.
"Serial Ports" Tab
bauds: RS232 / RS485 bauds. Can Choose between1200/2400/4800/9600 * /
19200/38400/57600/76800/96000/115200.
Data Bits: RS232 / RS485 data bits. Fix value, always in August.
parity: RS232 / RS485 stop bits. N * (None) O (odd) or E (even)
Stop Bits: RS232 / RS485 stop bits. Can choose 1 * or 2.
* Default parameters. The Most Important parameters Appear on display defaults When powered on.
"RTCC" Tab
Daylight Saving Time: Enable the summer time.
Time Zone: UTC Time Offsets.
18
Dynamic Manual 3
"TCP / IP" Tab
IP Address: IPv4 of unit. The displays are delivered With the default address 192.168.1.100 *
To connect to the display from a PC on a LAN must have the devices Both same network address. In This
case only the IP address and subnet mask are needed to Establish communication.
GatewaySet it if the internet access is Necessary.
Subnet Mask: The displays Come With the default subnet mask 255.255.255.0 *
Primary DNS server: For SNTP Synchronization use a public DNS like 8.8.8.8.
Secondary DNS server:For SNTP Synchronization use a public DNS like 8.8.4.4.
DHCP Client: The displays are shipped With DHCP disabled to work with a fixed address, but can Work
With automatic address by checking this box.
SNTP Synchronization: Automatic synchronizing each few minutes of the internal clock of the display to a
public Internet time server. The Internet access available and Should be Gateway address (Gateway) and
the DNS server must be correctly in September.
Protocol TCP Port for communication DTP: The TCP port will be used by That the native protocol called
DTP. Default TCP port is 53 *. MPTools use the DTP protocol, so If you change the TCP port don't forget to
change it too in "communication device and search" of the main menu.
CAUTION: To use SNTP Synchronization With the Wi-Fi communication the TCP port must be Set to
2000 in place of 53.
* Default parameters. The Most Important parameters Appear on display defaults When powered on.
19
Dynamic Manual 3
"Wi-Fi" Tab
SSID: Wireless Network Name (Maximum 32 characters).
Security: Open Network * or key type of wireless network security.
Security key: Security key if not open network.
Security Key length: Number of bytes (character) of the security key.
WEP key index: Only applicable in case of type 40 or WEP 104 WEP Security.
Network Type: Type of Wi-Fi network to connect Which we (Infrastructure * or AD-HOC).
Regional Domain: Wi-Fi geographical area Depending channels. ETSI: Europe *, FCC: USA or Japan.
NOTE: Wi-Fi communication needs Also the "TCP / IP" tab parameters. To connect from MPTools use the
same way than Ethernet in "Communication and Devices Search" of the main menu.
* Default parameters.
"TCP-ASCII Protocol" Tab
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Ditel Dynamic 3 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI