  • Hello! I've reviewed the GoodWe Smart Meter user manual and I'm ready to answer your questions about the GM1000D model. This manual covers installation instructions, wiring diagrams, electrical specifications, and operational details of the Smart Meter, including its reset and LED indications. Feel free to ask me anything.
  • What is the purpose of the Smart Meter?
    What is included in the packing list?
    What is the operating temperature?
    What is the function of the reset switch?
01 INTRODUCTION
PACKING LIST
GoodWe Smart Meter is designed with high precision small
dimensions, convenient operation and installation.
It is available for both single-phase grid system connection to
dectect voltage, current, power and energy, for working with
inverters including SEMS systems for the purpose energy
management.
Any fault or damage caused misoperation or disobeyal against
the rules on manual is beyond GoodWe warrenty cover range.
1*Smart Meter
1*Screw Driver
2*CT(Current Transformer)
8*Cable Connection Terminal
1*RJ45-to-Pin Cable[1]
NOTE:
[1] Only suitable for RS485 cable connection on RJ45
port of GoodWe hybrid inverters.
2.1 SMART METER OVERVIEW
02 OVERVIEW
3.1 INSTALLATION ENVIROMENT
3.2 INSTALLATION (WITH DIN TRACK)
Protection Class: IP20(for indoor use)
Operating Temperature: -25℃~+60℃
① Pull to release the retaining clip
② Mount the HomeKit on the track
and push the
Retaining clip up(a click sound
indicates it is installed well)
① Power LED
② Energy consumption LED
③ Communications LED
④ Reset switch
⑤ USB Port
Reset
SMART METER
USB
1 B(485B-)
2 A(485A+)
5 -(CT2-)
6 +(CT2+)
7 -(CT1-)
8 +(CT1+)
9 N
10 L1
11 L2
12 L3
36mm
USB
Reset
03 INSTALLATION INSTRUCITON
2.2 CT OVERVIEW
32mm 35mm
16mm
45mm
2M
USB
Smart Meter
USER MANUAL
No. 90 Zijin Rd., New District, Suzhou, 215011, China
[email protected] | www.goodwe.com
Reset
SMART METER
USB
3.3 WIRING CONNECTION
340-00341-01
Correct direction of CT: House (K)→Grid(L).
Incorrect connection or direction will cause incorrect data.
04 ELECTRICAL DATA
GM1000D
Single-phase
110V/230V
100V ~ 240V
50Hz/60Hz
CT in:120A/40mA
0.48A ~ 120A
3W max
Active / Reactive Power Energy
Class 1
Class 1
Class 2
MODEL
APPLICATION
Voltage
Self-Consumption
Data Detection
Energy Calculation
Precision
Communication
(With inverter)
Weight
Altitude
Nominal Voltage
Voltage Range
Frequency
Nominal Current
Current Range
Voltage / Current / Active Power
/ Reactive Power / Power Factor
/ Frequency
RS485 (Bund Rate 9600 / ModBus
Protocol / communication cable
max. length 100m)
Voltage/ Current
Active Power
Reactive Power
5.2 RESET SWITCH
5.1 INDICATIONS
• Power LED:
Normal status: ON
• Energy Consumption LED:
Consuming: ON
Generating: Blinking
• Communication LED:
Transmitting data: ON
Resetting: Blink 5 times
5.3 USB PORT
For after-sales maintenance.
05 INTERFACE
Press
<3s
5s
>10s
Function
Meter reset
Meter settings initialization
Meter initialize settings and clear energy data
AC coupled inverter
Grid-tie inverter
RS485
Grid
PV
House Meter
CT2
CT1
Load
House Grid
Current
Input
360g
<2000m
FUSE 0.5A
/