Action in
Field
Remember that water is one of the most dangerous element since it may
contain contaminants.
Drinkable water could be harmful to the appliances because of the chloride so
it does not represent any “security”
Always check chlorides, hardness and electrical conductivity
before installing any appliance!!!
Customer:
Address:
Postal code:
Town:
Phone:
Job No: PNC: Model:
Installation date: Serial No:
RANGE/UNIT READING
30 mA
see handbook
<0,1 Ohm
max 20 ppm
max 400 μS/cm
max 14°fH / 8°dH / 10°cH
max 40°fH / 22°dH / 28°cH
0,8÷7 bar
1,5÷7 bar
2÷3 bar
3÷7 bar
0,5÷3 bar
10÷15°C
max 50°C
See Tech. Bulletin PD15-00
see handbook
83÷90°C
35÷50°C
10÷35°C
55÷65°C
65÷75°C
50÷80°C
700÷1000 mm
Service Partner: Customer print name:
Tech. print name: Tech.No: Customer signature:
Tech. signature: Position:
Travel time: Labour time: Date:
Total hardness (for machines with water softener built-in)
Dynamic water pressure during filling (for atmospheric boiler in Rack Type / Flight Type)
Check working temperature range on prewash tank (compact & modular Rack Type only)
Training to end user
Check end limit switch on unloading table
Check emergency stop switch
Hood safety-microswitches work properly (automatic hood)
Comments (Non conformity/Suggestions):
Check temperature range on hot air blower/drying tunnel
Check discharge height of drain hose from machine base (if drain pump fitted)
Start and check a complete wash program
Check water leakage
Check working temperature range on boiler (see service or instruction manual if out of range)
Check working temperature range on prewash tank
Check working temperature range on wash tank
Check working temperature range on pre-rinse tank
Appliance levelling
Smooth movement of doors/hood
Rinse aid/detergent adjustment and connections
Pumps/motors/fans rotation (see printed arrow sense)
WATER TREATMENT INSTALLED
□
Reversal osmosys;
□
Nanofilter;
□
Softener;
□
No treatment
TESTING
Proceed with commissioning if installation is satisfactory. If not, report the problem to service manager and inform customer. If in doubt, refer to manufacturer instructions. In
the event of unsafe appliance or at risk situation, stop the appliance and inform immediately your service manager and issue a warning note.
Su
l
volta
e:
□
230-1N-50Hz;
□
400-3N-50Hz;
□
Other volta
e _________
Earth continuity between main grounded terminal and panels (Ohmmeter)
Check equipotential bonding connection
Total hardness (for machines without water softener built-in)
Dynamic water pressure during filling (for pressurized boiler in Rack Type / Flight Type)
Dynamic steam pressure during heating
Cold water temperature
Hot water temperature
RACK TYPE-FLIGHT TYPE
COMMISSIONING CHECK LIST:
DISHWASHING
PRELIMINARY CHECK LIST
Residual current circuit breaker
UC-HT WATER SOFTENER built-in
Dynamic water pressure during filling (for pressurized boiler)
Magnetic circuit breaker (automatic fuse)
UNDERCOUNT.-FRONT L.-GLASS W.
HOOD TYPE-POT WASHER
Dynamic water pressure during filling (for atmospheric boiler)
WATER CHECKING (from appliance inlet)
Chlorides
Conductivity
Check of documentation availability (handbook...)
CONNECTIONS
2