Alarm
code
Datalog description Description
Modular
1.56
Compact
1.57
32 WASH LEV. FAULT The pressure sensor on the wash tank does not work correctly.
33 WASH HEAT. TOUT
The required temperature in the wash tank was not reached within the max.
heating time.
34 WASH OVERTEMP. The water temperature in the wash tank is too high.
35 WASH NTC SHORT The wash tank temperature sensor is short-circuited.
36 WASH NTC OPEN The wash tank temperature sensor is open.
37 WASH PUMP1 THER. The upper wash pump thermal protector has tripped.
38 WASH PUMP2 THER. The lower wash pump thermal protector has tripped.
39 CU FAN THER. The CU (Condensing unit) fan thermal protector has tripped.
40 DRAIN WASH TOUT The wash tank was not completely emptied within the max. Emptying time.
51 PREW. FILL. TOUT The prewash tank was not completely filled within the max. filling time.
52 PREW. LEV. FAULT The pressure sensor on the prewash tank does not work correctly.
53 PREW. HEAT. TOUT
The required temperature in the prewash tank was not reached within the max.
heating time.
54 PREW. OVERTEMP. The water temperature in the prewash tank is too high.
55 PREW. NTC SHORT The prewash tank temperature sensor is short-circuited.
56 PREW. NTC OPEN The prewash tank temperature sensor is open.
57 PREW. PUMP THER. The prewash pump thermal protector has tripped.
58 DRAIN PREW. TOUT The prewash tank was not completely emptied within the max emptying time.
71 DT HEAT. TOUT
The required temperature in the drying tunnel was not reached within the max.
heating time.
72 DT OVERTEMP. The drying tunnel temperature is too high.
73 DT NTC SHORT The drying tunnel temperature sensor is short-circuited.
74 DT NTC OPEN The drying tunnel temperature sensor is open.
75 DT FAN THER. The drying tunnel fan thermal protector has tripped.
76 MOT CURR OOR H
The gear motor supplied current is higher than the maximum value allowed for
the “Max motor curr.” parameter.
77 MOT CURR OOR L
The gear motor supplied current is lower than the minimum value allowed for the
gear motor current.
78 HIGH MOT CURR.
The gear motor supplied current is higher than the value set in the “Max motor
curr.” parameter.
82
BOIL. USA HEAT.
TOUT
The required temperature was not reached in the first boiler within the max.
heating time.
83
BOILER USA
OVERTEMP.
The water temperature in the first boiler is too high.
84
BOILER USA NTC
SHORT
The first boiler temperature sensor is short-circuited.
85
BOILER USA NTC
OPEN
The first boiler temperature sensor is open.
89 U.I. TEMP. HIGH The temperature on the user interface is too high.
90 ECAP ERROR Communication problems between machine electronic boards.
91 ----------
User interface board (modular rack type) or power board connected to the user
interface board (compact rack type) out of order.
Alarms (the machine stops)
Warnings (the machine does not longer stop)
Warnings or alarms (depending of the type of the machine)
Share more of our thinking at www.electrolux.com