Subject
Model
Modular Rack Type range (Electrolux WTM series) and Compact Rack Type
range (Electrolux WTC series and Zanussi RTC series).
Problem
The machine stops too often.
Reason
All alarms stop functioning.
Action in
Factory
Since serial number 71900001 we have introduced new firmware release with
reviewed alarms to avoid that machines stop working for minor anomalies.
Just a warning message appears.
Here below the list of all alarm codes where warnings (the display shows the
code but the machine does not stop) are highlighted in green and alarms (the
machine stops working) are highlighted in red:
Alarm
code
Datalog description Description
Modular
1.56
Compact
1.57
11 AIRG. FILL. TOUT The Air Gap was not completely filled within the max. filling time.
12 AIRG. LEV. FAULT The pressure sensor on the air gap does not work correctly.
13 DUO FILL. TOUT The Duo-Rinse tank was not completely filled within the max.filling time. n.a.
14 DUO LEV. FAULT The pressure sensor on the Duo-Rinse tank does not work correctly. n.a.
15 BOIL. HEAT. TOUT
The required temperature was not reached in the boiler within the max.heating
time.
16 BOILER OVERTEMP. The water temperature in the boiler is too high.
17 BOILER NTC SHORT The boiler temperature sensor is short-circuited.
18 BOILER NTC OPEN The boiler temperature sensor is open.
19 DUO HEAT. TOUT
The required temperature was not reached in the Duo-Rinse tank within the
max. heating time.
n.a.
20 DUO OVERTEMP. The water temperature in the Duo-Rinse tank is too high. n.a.
21 DUO NTC SHORT The Duo-Rinse tank temperature sensor is short-circuited. n.a.
22 DUO NTC OPEN The Duo-Rinse tank temperature sensor is open. n.a.
23 RIN. PUMP THERM. The rinse pump thermal protector has tripped.
24 DUO PUMP THERM. The Duo-Rinse pump thermal protector has tripped. n.a.
25 DRAIN DUO TOUT The Duo-Rinse tank was not completely emptied within the max. emptying time. n.a.
27 INVERTER ERROR The gear motor inverter has generated an alarm.
30 DRAIN AIRG. TOUT The Air gap was not completely emptied within the max. Emptying time.
31 WASH FILL. TOUT The wash tank was not completely filled within the max. filling time.
ELECTROLUX PROFESSIONAL SPA
MAILING ADDRESS TELEPHONE WEBSITE VAT NO.
VIA SEGALUZZA, 30
33170 PORDENONE - ITALY
++39 0434 380650 www.electrolux.com 00072220932
OFFICE ADDRESS TELEFAX E-MAIL ADDRESS
VIA SEGALUZZA, 30
33170 PORDENONE - ITALY
++39 0434 380636
++39 0434 385646
Share more of our thinking at www.electrolux.com
Alarm
code
Datalog description Description
Modular
1.56
Compact
1.57
32 WASH LEV. FAULT The pressure sensor on the wash tank does not work correctly.
33 WASH HEAT. TOUT
The required temperature in the wash tank was not reached within the max.
heating time.
34 WASH OVERTEMP. The water temperature in the wash tank is too high.
35 WASH NTC SHORT The wash tank temperature sensor is short-circuited.
36 WASH NTC OPEN The wash tank temperature sensor is open.
37 WASH PUMP1 THER. The upper wash pump thermal protector has tripped.
38 WASH PUMP2 THER. The lower wash pump thermal protector has tripped.
39 CU FAN THER. The CU (Condensing unit) fan thermal protector has tripped.
40 DRAIN WASH TOUT The wash tank was not completely emptied within the max. Emptying time.
51 PREW. FILL. TOUT The prewash tank was not completely filled within the max. filling time.
52 PREW. LEV. FAULT The pressure sensor on the prewash tank does not work correctly.
53 PREW. HEAT. TOUT
The required temperature in the prewash tank was not reached within the max.
heating time.
54 PREW. OVERTEMP. The water temperature in the prewash tank is too high.
55 PREW. NTC SHORT The prewash tank temperature sensor is short-circuited.
56 PREW. NTC OPEN The prewash tank temperature sensor is open.
57 PREW. PUMP THER. The prewash pump thermal protector has tripped.
58 DRAIN PREW. TOUT The prewash tank was not completely emptied within the max emptying time.
71 DT HEAT. TOUT
The required temperature in the drying tunnel was not reached within the max.
heating time.
72 DT OVERTEMP. The drying tunnel temperature is too high.
73 DT NTC SHORT The drying tunnel temperature sensor is short-circuited.
74 DT NTC OPEN The drying tunnel temperature sensor is open.
75 DT FAN THER. The drying tunnel fan thermal protector has tripped.
76 MOT CURR OOR H
The gear motor supplied current is higher than the maximum value allowed for
the “Max motor curr.” parameter.
77 MOT CURR OOR L
The gear motor supplied current is lower than the minimum value allowed for the
gear motor current.
78 HIGH MOT CURR.
The gear motor supplied current is higher than the value set in the “Max motor
curr.” parameter.
82
BOIL. USA HEAT.
TOUT
The required temperature was not reached in the first boiler within the max.
heating time.
83
BOILER USA
OVERTEMP.
The water temperature in the first boiler is too high.
84
BOILER USA NTC
SHORT
The first boiler temperature sensor is short-circuited.
85
BOILER USA NTC
OPEN
The first boiler temperature sensor is open.
89 U.I. TEMP. HIGH The temperature on the user interface is too high.
90 ECAP ERROR Communication problems between machine electronic boards.
91 ----------
User interface board (modular rack type) or power board connected to the user
interface board (compact rack type) out of order.
Alarms (the machine stops)
Warnings (the machine does not longer stop)
Warnings or alarms (depending of the type of the machine)
Share more of our thinking at www.electrolux.com
2
Action in
Field
Spare part codes don’t change and “new” boards are perfectly
interchangeable towards previous ones.
The new firmware release above (1.56 for WTM and 1.57 for RTC/WTC) can
be implemented only if you update all boards, i.e. both user interface and
MEC boards.
All boards in Pordenone and Herbon warehouse are being updated.
production
code
Spare part code
OLD
release
NEW
release
MEC board
673610101
0L1284
1.52
1.56 Modular RT
WTM
User interface
673610001
0L1285
1.52
1.56
MEC board
673610201
0L1291
1.53
1.57 Compact RT
RTC / WTC
User interface
673608202
0L1196
1.53
1.57
MEC = Multi-platform Electronic Control
You can check the firmware release either by switching machine on (the
display shows the firmware release of each board) or by reading the supplier’s
label on the board.
For instance:
Firmware release 1.56
MEC board 0L1284 for
Modular RT (WTM)
Share more of our thinking at www.electrolux.com
3
  • Page 1 1
  • Page 2 2
  • Page 3 3

Electrolux 727104 (RS06FX1FR) Datasheet

Type
Datasheet

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI