Watts 0958247 User manual

Type
User manual

This manual is also suitable for

Whole House Filtration with Pressure Relieve Valve
Watts Premier • 1725 W. Williams Drive #C20 • Phoenix, AZ 85027
1-800-752-5582 • www.wattspremier.com
Model: 500228
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Please read carefully before proceeding with installation. Your failure to follow any attached instructions
or operating parameters may lead to the product’s failure.
Save manual for future reference
Warning
Rev. Date 01/27/2010 Manual # 299111
Watts Premiers Whole House Filtration with pressure relieve valve
Watts Premiers Whole House Filtration system should be installed on the main cold wa-
ter line servicing the house and installed in location that is protected of the environment.
Watts Premier does not take any responsibility for the plumbing of the system into the
water line. Install accordingly to your local plumbing codes.
Watts Premiers Whole House Filtration system comes with one inch quick connect t-
tings. If your water line is smaller than one inch you will need to use proper reducers for
the installation (not included).
Note: Only Teon tape should be used on threaded ttings, do not use pipe dope as it may
cause damage to the plastic threads.
Installation Tools & Materials Recommended:
For Typical Installation:
- Pipe Cutter or Hack Saw
- 1/2” Open-end Wrench & Adjustable Pipe Wrench
- Variable Speed Drill
- Teon Tape (Supplied)
Operational Parameters:
1. Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system.
2. Operating Temperatures:
Maximum 100F (37.8C)
Minimum 40F (04.4C)
3. Operating Pressures:
Maximum 85 PSIG (5.95 kg/cm2)
Minimum 5 PSIG (0.35 kg/cm2)
4. Maximum Flow Rate:
22 GPM @ 60 psig
83.27 LPM @ 4.20 kg/cm2
3: Installation Kit
Use caution when tightening plastic ttings as overtightening may cause damage.
3.1 The installation kit includes: (1) 1” Brass Ball Valve, (1) 1” Brass Hex Nipple,
(2) 1” Plastic Quick connect ttings, (2) Rolls of Teon tape.
3.2 Wrap the Teon tape on all male threaded ttings 5 to 6 full wraps in a clockwise
direction.
3.3 Thread the brass hex nipple into the brass valve end facing away from the handle
(in the “open” position) and tighten.
3.4 Thread the plastic quick connect tting into the open end of the brass ball valve and
tighten.
3.5 Thread the brass hex nipple side of the ball valve assembly into the black housing lid port
labeled “IN” and tighten. Make sure that the ball valve handle is facing towards you once
fully threaded.
3.6 Thread the second plastic quick connect tting into the black housing lid port labeled
“OUT” and tighten.
Plastic Quick
Connect Fitting
Brass Ball Valve
Brass Hex Nipple
Metal Mounting Bracket
Plastic Quick
Connect Fitting
OUT
IN
FLOW
Handle “Open”
1.1 Check to see what is the size of water line that you will be tapping into.
1.2 Verify what material your water pipe is made of; Copper, PVC schedule 40/80, Black
Iron or Galvanized pipe. Watts Quick Connect ttings accept all water pipe materials.
1.3 If needed, purchase the required ttings and/or materials from your local hardware or
plumbing center to make the connections to the Whole House system. PVC
reducing bushings are recommended if the porting requires reducing.
1: Water Line
2: Mounting of Bracket
2.1 The direction of your water ow through your homes plumbing will determine the way
the bracket is mounted on the lter lid.
2.2 Align the small pattern of hole on the bracket with the hole patterns of the lter lid.
2.3 Using the four 5/16 lag bolts and at washers attach the bracket to the lter lid,
do not overtighten!
*** The lter should be changed every six months or sooner if needed. ***
System Maintenance
To change your lters, shut off the main water supply using the ball valve on the ltration
system and open a faucet downstream of the system to reduce water pressure. Push the Red
Pressure Relieve Valve on top of the housing lid to depressurize the unit. The lter bowl can be
removed by turning it clockwise.
Remove old lter and discard. Rinse lter bowl and replace lter. Use a water soluble lubricant
to lubricate the O-ring . Make sure O-ring is properly seated when replacing lter bowl. Do not
over-tighten housing.
4.3 Mount the system to the wall using the mounting bracket.
4.4 Pipe ends that will connect to the quick connect ttings should have a clean smooth nish
for proper seal against the inner O-rings. Rough edges should be sanded down to prevent
damage to the O-rings or any part of the quick connect ttings.
4.5 To make a connection, push the water pipe into the quick connect tting until fully
seated. Approximately 1.5” of the water pipe should go into the quick connect tting
when installed properly.
Plumb water line to system while making sure that the ow direction is correct through the lter
system. (IN/OUT)
Note: A manual by-pass may be installed
5: Start-Up
5.1 Open a faucet down stream of the Whole House lter unit.
5.2 Turn on the main water supply and check for leaks at all connections to system.
5.3 Close the faucet down stream of the Whole House Filter unit and check for leaks.
Monitor for leaks for 24 hours after installation.
Note: This system will weight approximately 18 pounds when in service.
4: Connecting to Water Line
4.1 Shut off main water supply and open a faucet down stream to allow draining of water out
of water pipes.
4.2 Cut the water line where the Whole House Filter System is to be installed. Make sure the
location allows for future servicing of the system.
Trouble Shooting
Problem Possible Cause Solution
1. Filter bowl has no water in it. Water is not turned on. Turn water on.
Ball Valve Turned “OFF” Make sure valve handle is
inline with the piping “ON”.
2. Leaking at the bowl. O-ring kinked or not seated. Check / Replace / Re-seat O-ring.
Bowl not tightened enough. Tighten bowl.
3. Leaking at the valve ttings. Improper installation Replace or repair ttings.
4. Leaking at top of valve (lid). Faulty lid. Call Watts Premier at 1-800-752-
5582 for replacement.
5. Low water ow / pressure. Filter clogged. Replace lter.
1725 W. Williams Dr. C-20 Phoenix, Arizona 85027
Limited Warranty
What your Warranty Covers:
If any part of your WATTS PREMIER unit is defective in workmanship (excluding replaceable lters ), return
unit after obtaining a return authorization (see below), within 1 year of original retail purchase, WATTS
PREMIER will repair or, at WATTS PREMIER’S option, replace the system at no charge.
How to obtain Warranty Service:
For warranty service, call 1-800-752-5582 for a return authorization number. Then, ship your unit to our
factory, freight and insurance prepaid, with proof of date of original purchase. Please include a note stating
the problem. Premier will repair it, or replace it, and ship it back to you prepaid.
What this warranty does not cover:
This warranty does not cover defects resulting from improper installation, (contrary to WATTS PREMIER’S
printed instructions), from abuse, misuse, misapplication, improper maintenance, neglect, alteration,
accidents, casualties, re, ood, freezing, environmental factors, water pressure spikes or other such acts of
God.
This warranty will be void if defects occur due to failure to observe the following conditions:
1. The System must be hooked up to a potable municipal or well cold water supply.
2. The pH of the water must not be lower than 5 or higher than 10.
3. The incoming water pressure must be between 20 and 85 pounds per square inch.
4. Incoming water to the Counter Top cannot exceed 100 degrees F (38 degrees C.)
This warranty does not cover any equipment that is relocated from the site of its original installation.
This warranty doe not cover any charges incurred due to professional installation.
This warranty does not cover any equipment that is installed or used outside the United States of America and
Canada.
LIMITATIONS AND EXCLUSIONS:
WATTS PREMIER WILL NOT BE RESPONSIBLE FOR ANY IMPLIED WARRANTIES, INCLUDING THOSE
OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. WATTS PREMIER WILL NOT
BE RESPONSIBLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, INCLUDING TRAVEL
EXPENSE, TELEPHONE CHARGES, LOSS OF REVENUE, LOSS OF TIME, INCONVENIENCE, LOSS
OF USE OF THE EQUIPMENT, AND DAMAGE CAUSED BY THIS EQUIPMENT AND ITS FAILURE TO
FUNCTION PROPERLY. THIS WARRANTY SETS FORTH ALL OF PREMIER’S RESPONSIBILITIES
REGARDING THIS EQUIPMENT.
OTHER CONDITIONS:
If WATTS PREMIER chooses to replace the equipment, WATTS PREMIER may replace it with reconditioned
equipment. Parts used in repairing or replacing the equipment will be warranted for 90 days from the date the
equipment is returned to you or for the remainder of the original warranty period, whichever is longer. This
warranty is not assignable or transferable.
YOUR RIGHTS UNDER STATE LAW:
Some states do not allow limitations on how long an implied warranty lasts, and some states do not allow the
exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not
apply. This warranty gives you specic legal rights, and you may have other legal rights which vary from state
to state.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Watts 0958247 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI