Application sheet
BasicGrip
Carpet / tiles / parquet / laminate / synthetics
Cement-screed
1
2
3
4
5
1 Carpet / tiles / parquet
2 Cement-screed 65 mm
3 FH composite pipe (16 mm)
4 BasicGrip panel 11mm insulation 11 mm
5 Insulation WLG 040 40 mm
6 Basic perimeter insulation
Floor nish NA mm Carpet / tiles / parquet / laminate / synthetics
Construction height 116 mm Height excluding oor nish
Weight ~ 138 kg / m² Weight excluding oor nish
Thermal resistance R 1,31 m²K / W The minimum thermal resistance requirement of DIN EN 1264 is
fullled.
Thermal transmission coecient U 0,76 W / m²K If the architectural design species better thermal insulation, this
must be taken into account.
Design load ≤ 2,0 kN / m²
Point load (≥ 20 cm²) ≤ 1,0 kN
Application area
Residential spaces, hallways and attic spaces in residential buildings and hotel rooms.
Corresponds to categories A1, A2 and A3 of DIN 1055-3.
Requirements & special features
The R value must be increased if the groundwater level is less than or equal to 5 m. A
U value not exceeding 0.5 W/m²K must be maintained in existing buildings and addi-
tions with areas up to 50 m². Structural sealing according to DIN 18195 must be placed
beneath the oor panel in case of structures facing the ground, and otherwise on the
unnished oor. The screed thicknesses must be adjusted in case of higher design load
or point load values.
Observe all installation instructions and manufacturer’s instructions.
Additional insulation
Insulation: 40 mm EPS 040 DEO
Construction
According to EnEV, EN 1264, DIN 4109, 1055 and 18560
Construction number 170
Technical Data Floors/ceilings facing unheated rooms or the ground
6
© Danfoss 11/2008
VA.CT.T1.02