TH450
Page 15 - Manual FA01031-IT - 08/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
Page 15 - Manual FA01432-EN - 03/2020 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Translation of the original instructions
reappears on the screen to confi rm that the temperature ranges have been programmed.
The device exits the procedure 10 seconds after the last action and the data entered up
to that moment are accepted as valid.
Note. The value that can be assigned to each temperature range is limited by the values
of the range immediately above and below it.
If, for example, range T3 is set at 20°C and range T1 is set at 16°C, the value of range
T2 can vary between 16.1°C and 19.9°C; if T2 is set at 21°C, T3 is automatically
increased to 21.1°C.
Press button .
The icon appears to confi rm
that the programme has been
activated.
Use of the all-purpose program
The device includes an all-purpose programme (to be used, for example, during holidays
or on midweek public holidays) that can be activated at any time of the current day and
remain active until 24:00. It can also be pre-requested for use on any day of the week.
The all-purpose programme is factory set to the same profi le as the one set for Sundays
, but it can be customised.
To activate this programme for the current day:
Set the AUTOMATIC operating mode.
Press button P to confirm the
temperature value shown on the
display and move on to the next
temperature level .
Continue as described to set all
the temperature ranges as you
want them.
The entire daily programme chart