Parameter Display Defaults Setting range
Display
condition
IN-P aMA2
•
-
UNIT ?C
type
sensor
dUNT ?/O
type
Analog
L-RG 0$00
H-RG 2)00
position
dP )0
• Set the decimal point position of the
L-SC 00)0
H-SC 10)0
correction
IN-B 000 -999 to 999 -
lOR1
0$00
[Transmission
-
0)00
[Transmission
hOR1
2)00
[Transmission
-
1)00
[Transmission
lOR2
0$00
[Transmission
-
0)00
[Transmission
hOR2
2)00
[Transmission
-
1)00
[Transmission
BAR OUT1 [Transmission output model]
lOU1 00)0
[Transmission output model]
sensor input
emperature range
Analog input
to scale
-
hOU1 10)0
lOU2 00)0
hOU2 10)0
transmission
output
extension
ExIO 5P
[Transmission output model]
the analog input range
type
Analog
&
operation
AL-1
AT!A
low limit alarm
-
option
standardlatch
•
-
operation AL-2
AT@A
[Alarm output model]
option'
•
-
option
operation AL-3
AT!A
option
operation AL-4
AT@A
option
Alarm output
hysteresis A-HY 001 [Alarm output model]
Alarm
operation
option
Program Mode
Universal input
Parameter Display Defaults Setting range
Display
condition
function InSF LIN
type
Analog
pressure )PSI 0*00
typeAnalog
&
special
function
correction SPAN !000
type
Analog
&
AvF 01
MAvF 04
DI-K HOLD
-
COLR GRN
normalerror occur
-
Sensor
disconnection
alarm output
BURN ON
type
sensor
level USER STND -
LOCK OFF
program-
setting
program mode
and setting
program mode
-
Pressure of pressure sensor
Pulse input
Parameter Display Defaults Setting range
Display
condition
IN-P 50KH
•
-
dUNT KHZ -
L-RG 0)00
-
H-RG 5)00
position
dP )00
• Set the decimal point position of the
-
L-SC 0)00 -
H-SC 5)00
correction
IN-B 000 -999 to 999 -
lOR1
0$00
[Transmission
-
0)00
[Transmission
hOR1
2)00
[Transmission
-
1)00
[Transmission
lOR2
0$00
[Transmission
-
0)00
[Transmission
hOR2
2)00
[Transmission
-
1)00
[Transmission
BAR OUT1 [Transmission output model]
lOU1 0)00
[Transmission output model]
to scale -
hOU1 5)00
lOU2 0)00
hOU2 5)00
transmission
output
extension
ExIO 5P
[Transmission output model]
the analog input range
operation
AL-1 AT!A
low limit alarm
-
option
standardlatch
•
-
operation AL-2 AT@A
[Alarm output model]
option
•
-
option
operation AL-3 AT!A
option
operation AL-4 AT@A
option
Alarm output
hysteresis A-HY 001 [Alarm output model]
Alarm
operation
option
correction SPAN !000
MAvF 04
DI-K HOLD
-
color COLR GRN
normalerror occur
-
level USER STND -
LOCK OFF
program-
setting
program mode
and setting
program mode
-
Reset
01.
02. Displays the setting value as NO by pressing the [MODE] key.
03. or
04. Press the [MODE] key to reset all parameter values as default and to return
to run mode.
•
Error
Display Description Troubleshooting
LLLL
automatically when it is in the
measured and using range.
HHHH
BURN
disconnected
ERR
setting conditions.
ERR2
setting.
Sensor disconnection
alarm output
Transmission output
(DC 4 - 20 mA)
Alarm output
Absolute
alarm
Absolute
alarm
OFF
OFF OFF
Input Type and Using Range
Universal input
Pulse input
•
•
•
•
Input type Display Using range ()Using range ()
Cu50
Cu10
JPt1
DPt5
DPt1
Thermocouple
TcK1
TcK2
TC-J
TC-E
TC-T
TC- B
TC-R
TC-S
TC-N
TC-C
TC-L
TC-U
TC-P
Analog
aMA1
• The using range varies depending on the
decimal point position.
aMA2
aMV1
aMV2
A-V1
A-V2
Input type Measuring cycle Display Using range
Pulse
10H
• The using range varies depending on the
decimal point position.
100H
1KH
10KH
50KH