This hood is equipped with an electronic motor and lamp
control.Thecontrolisabletoset3differentfanspeeds,turn
ON/OFF light and has a timer function. In the following draw-
ing are described the main key functions.
1. Timer Key
The default timer setting is 10 minutes, and it can be
adjustedbetween20minutesand1minute.
After pressing the timer key, the control enters to a timer
setup mode, and user can adjust the timer countdown
timewiththe“-”and“+”keyswithin5seconds.Thetimer
can be initiated immediately pressing the timer key, after
setting the timer duration or pressing the timer key twice
(default10minutessetting).
If not action occurs within 5 seconds the countdown will start.
Duringthetimersetupthe“-”and“+”keysarededicated
to the timer and no motor action will occur.
Once initiated the timer, it can be cancelled by pressing
the timer key again.
2. Light Key
PresslampkeytoturnONthelight(LampstatepreviouslyOFF).
PresslampkeytoturnOFFthelight(LampstatepreviouslyON).
3. Display
Shows the hood settings.
4. “-” Key. Speed Decrease / OFF
This key is used to decrease the fan speed, or turn OFF
the fan.
ThefanwillturnOFFifthe“-”keyispressedandthe
hoodwasintherstspeed.
Ifthefanisatsecondspeedandthe“-”keyispressed,
thefanwillbesettorstspeed.
Ifthefanisatthirdspeedandthe“-”keyispressed,the
fan will be set to second speed.
IfthefanisOFFandthe“-”keyispressed,thecontrol
backlight will light up.
5. “+” Key. Speed Increase / ON
This key is used to increase the fan speed, or turn
ON the fan.
ThefanwillturnONifthe“+”keyispressedandthe
hood was OFF.
Ifthefanisatrstspeedandthe“+”keyispressed,
the fan will be set to second speed.
Ifthefanisatsecondspeedandthe“+”keyispressed,
the fan will be set to third speed.
Ifthefanisatthirdspeedandthe“+”keyispressed,
a beep will sound.
Special functions
Clock programming
The clock can be reprogrammed at any time except
during an active timed function.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
1 2 3
The clock can be displayed in a twelve hour format and
validclocktimesarefrom1:00to12:59.
Theclockcanbereprogrammedpressingthe“Timer”
key for 5 seconds, and after, the clock can be adjusted
withthe“+”and“-”keys.Colon“:”willashindicating
clock programming mode.
The user can have minute increments / decrements of 1
minute,butiftheuserkeeppressingthe“+”/”-”keys
for more than 1 second, the increments / decrements will
be of 5 minutes. During this option the control will
round to the nearest 5 minutes.
Theusercannishonreprogrammingtheclockpressing
the“timer”key.
After 1 minute of no key pressed the control will accept
the programmed clock time and will add one minute
to the set clock.
Grease lter saturation alarm
After thirty fan functional hours, the display will show
“GreaseFilter”ifthefanisactive.Whenthisiconis
showninthedisplay,thegreaseltersinstalledare
required to be washed.
Toresetthegreaseltersaturationalarmtheusermust
pressthe“+”keyfor5seconds,afterthisactionthe
icon“greaselter”isnotdisplay,andthehoodhasthe
normal display operation.
Charcoal lter saturation alarm (Recirculating accessories)
After one hundred and twenty functional hours of the fan,
thedisplaywillshow“CharcoalFilter”ifthefanisactive.
Whenthisiconashesondisplay,thecharcoallters
installed are required to be replaced or reactivated.
Toresetthegreaseltersaturationindicationtheuser
mustpressthe“-”keyfor5seconds,afterthistime
theicon“charcoallter”isnotdisplayandthehoodhas
the normal display operation.
Audible signal activation and deactivation
The audible signals can be activated or deactivated
pressingthe“Light”keyfor5seconds.
If the audible signal is activated, a tone must sound and
the“Snd”symbolmustappearonthedisplayfor2second.
Iftheaudiblesignalisdeactivated,the“Snd”symbolmust
appearonthedisplayfor2secondandnosoundmustsound.
Charcoal lter inclusion and exclusion
(Recirculating accessories)
Thecharcoallterinclusionorexclusioncanbesetby
pressingthe“-”and“+”keysatthesametimefor5seconds.
TheInclusionorexclusionofcharcoalltermustbe
selected while the lamps and the motor are OFF.
Whenthecharcoalhasbeenexcluded,thecharcoallter
alarm is disabled.
Heat sensor
The control is equipped with a heat sensor that will turn
on the blower at second speed if excessive heat
occurs(over70°C)surroundingthecontrolarea.
IftheblowerisOFForifitisoperatingatrstspeed,the
blower will be set automatically to second speed.
During this state, the user may raise the blower speed to
third speed but can not decrease the speed.
When the temperature level on the hood drops to normal,
theblowerwilloperateinthesettingdenedbytheuser
before the alarm occured.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•