1. Turn off the power before installation. Remove the
existing fixture if applicable.
2. Determine the location for installation and cut
ceiling hole with approximate dimensions of 4.25” x
4.25" or 108mm x 108mm. (Fig. 1)
3. Open the DRIVER/JUNCTION BOX cover and
remove the appropriate knockout(s) on the side
panel (Fig. 2). Install the appropriate cable clamp(s)
(not included) and insert the electrical supply cable
through the cable clamp. Connect the ground wire to
the green wire terminal, hot wire to the black wire
terminal and neutral wire to the white wire terminal
using the wire nuts provided.
4. Place all wiring and connections back into the box
and close the cover. Connect the
DRIVER/JUNCTION BOX to the light panel using the
CONNECTOR.
5. Insert DRIVER/JUNCTION BOX through the
mounting hole (Fig. 3) and secure using mounting
tabs.
6. Push the SPRING-LOADED CLIPS into the
mounting hole upwards and insert LIGHT PANEL
into it. Release the clips and the fixture will be pulled
flush to the ceiling. (Fig 4)
WARNING / ATTENTION
CAUTIONS
NOTES
The units covered in these instructions are intended to retrofit Type IC or Type Non-IC luminaries.
Risk of fire. Supply conductors (power wires) connecting to the fixture must be rated 90° C. If
uncertain, consult an electrician.
Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaries electrical
systems.
Risk of fire or electric shock. If not qualified, do not attempt installation. Contact a qualified
electrician.
Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features
and dimensions shown in the photographs and/or drawings.
To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp
objects.
This lamp is not intended for use with emergency exit fixtures or emergency lights.
For your safety read and understand instructions completely before starting installation.
Before attempting installation, check your local electric code, as it sets wiring standards
for your locality.
If luminaire (fixture) is to be switched from a wall switch, make sure black power supply wire
is connected to the switch. DO NOT connect the white supply wire to the switch.
Make sure no bare wires are exposed outside the wire nut connectors.
Do not make or alter any open holes in an enclosure of wiring or electrical components