2
This mantel kit contains the following pieces:
Finished Unfinished
• Header right leg 103487-01 103487-02
• Header left leg 103487-03 103487-04
• Header 103487-05 103487-06
• Header blocks (4) 101527-01 101527-01
• Mounting strips (2) 101534-01 101534-01
• Header top 103487-07 103487-08
• Batten molding strip 103468-17 103468-18
• Hardware package 101542-01 101542-01
• Brass Trim Kit 102753-01 102753-01
• Trim Kit Hardware 102865-01 102865-01
Tools required:
• #2 Phillips screw driver (regular length)
• Electric drill
• 5/16" drill bit
• Hammer
• Pencil
• Level
• Measuring Tape
• Hand or electric saw
Hardware required:
• 4 - 2
1
/2" Load-bearing Nails
If any of these pieces are missing or damaged, contact the dealer where you purchased this kit or call DESA International’s Parts
Department at 1-800-972-7879 for information.
3. Lay mounting strips on the floor. Place left and right legs face
down on mounting strips. Use the mounting strips to give you
a flat surface to work on while attaching legs to header. Set
header between right and left legs (see Figure 2
, page 3
).The
mounting blocks should overhang the side panels.
IMPORTANT:
To avoid damage to wood, do not kneel, lean,
or apply any pressure on the front panel in this position.
Slide header flush against left legs. Align top of both pieces.
Insert 1
1
/
4
" wood screws through predrilled holes in mounting
blocks (see Figure 2, page 3). Make sure top of header and legs
are still flush and all pieces fit tightly together. Tighten screws
to fasten header to left leg. Repeat to attach header to right leg
(see Figure 2, page 3).
NOTE:
The mantel assembly will be loose until you attach the top.
WARNING ICON G 001
WARNING
Use care when finishing an unfinished mantel.
Finish pieces before assembly. Do not finish
mantel pieces near running heater or open flame.
Vapors from most finishing products are highly
flammable. Follow manufacturer’s guidelines when
using finishing products.
I
MPORTANT:
If you are painting an unfinished mantel, apply an oil
base undercoat to the mantel before painting. This will seal the wood.
After undercoat dries completely, lightly sand and apply an oil base
top coat. If you do not apply an oil base undercoat and topcoat, the
wood grain will bleed through the paint.
1. Mantel must be installed flush with wall. Baseboard will pre-
vent proper installation of mantel. Baseboard can either be
altered to fit mantel or removed.
Note:
To avoid scratching mantel front pieces during assembly, place
a sheet or blanket on floor where mantel will be assembled.
2. Remove header front panel from carton. Note position of or-
nament on front to identify top of piece. Place header front
panel face down on floor. Attach one header block to bottom
left of header (about 1
1
/2" up) with one 1
1
/4" wood screw,
leaving remainder of block to overhang about one half its length
(see Figure 1). Attach one header block to the top left of header
(about 1
1
/2" down) with one 1
1
/4" wood screw, leaving re-
mainder of block to overhang about one half its length (see
Figure 1). Repeat above steps to attach the other two header
blocks to right side of header.
Header
(Face Down)
Figure 1 - Attaching Header Blocks to Header
Header Blocks
1
1
/4" Wood Screws
IMPORTANT:
Read entire instruction sheet before assembling or installing mantel kit.
This mantel is only approved for use with CGFP28 and LF33R series natural gas and propane heaters and CGFB32 series
fireboxes. Do not use mantel with any other product.
WARNING
Carefully remove each mantel piece one at a time from the shipping carton. Do not
try to lift all of the parts out of the box at once. This may damage mantel pieces.
GMC36F & GMC37U CORNER MANTEL KIT
Assembly and Installation Instructions