M22311 Series

ABB M22311 Series, M22313 Series, Welcome M22344-W User manual

  • Hello! I am an AI chatbot trained to assist you with the ABB M22311 Series User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
VER:1.2 28.04.2017
ABB-Welcome
Pos: 2 /D inA4 - Anl eit ungen Onli ne/I nhal t/KN X/Doo rEnt ry/ 83220-A P- xxx/ Tit elblat t - 832 20-A P-xxx - AB B @ 1 9\m od_132 3249 806 476 _15.doc x @ 11 108 4 @ @ 1
M22344-W
Basic 4.3" video hands-free
indoor station
ABB
-Welcome
| — 2 —
Pos: 4 /B usc h-Ja eger (N eust rukt ur)/ Modul-S t ruktu r/Onli ne-D oku ment ation /Inh altsve rzeic hni s (--> Fü r alle Doku men te <-- )/In haltsve rzeic hnis @ 19\ mod _13206 490 4438 6_15.d ocx @ 109 653 @ @ 1
1 Safety ....................................................................................................... 3
2 Intended use ............................................................................................. 3
3 Environment .............................................................................................. 3
3.1 ABB devices ............................................................................. 3
4 Operations ................................................................................................ 5
4.1 Standard operations .................................................................. 5
4.1.1 Control elements ....................................................................... 5
4.2 Control actions .......................................................................... 7
4.2.1 Incoming call/in a call ................................................................ 7
4.2.2 Display and volume settings during a call ................................... 8
4.2.3 Communication menu ............................................................... 9
4.3 Settings .................................................................................. 11
4.3.1 Overview ................................................................................ 11
4.3.2 Switch actuator settings ........................................................... 12
4.3.3 Program button settings .......................................................... 13
4.3.4 Ringtone settings .................................................................... 14
4.3.5 Volume settings ...................................................................... 15
4.3.6 Date and time settings ............................................................. 16
4.3.7 Other settings ......................................................................... 17
4.3.8 History review ......................................................................... 18
4.3.9 Language settings ................................................................... 20
4.3.10 Information.............................................................................. 20
4.3.11 Resetting factory default .......................................................... 21
4.4 Cleaning ................................................................................. 22
4.5 Adjusting the device ................................................................ 23
5 Technical data......................................................................................... 24
6 Mounting/Installation ............................................................................... 25
6.1 Requirements for the electrician............................................... 25
6.2 General installation instructions ............................................... 27
6.3 Mounting ................................................................................. 28
ABB
-Welcome
Pos: 6 /B usc h-Ja eger (N eust rukt ur)/ Modul-S t ruktu r/Onli ne-D oku ment ation /Übe rschri ften (--> Für alle D okum ent e <--)/ 1. Eb ene/S - T/S icher heit @ 18\ mod _13 026127 917 90_ 15.d ocx @ 103 357 @ 1 @ 1
1 Safety
Pos: 7 /B usc h-Jaege r (N eust rukt ur)/Mo dul-St ruktu r/Onli ne-D oku ment ation /Si cher heit (-- > Für al le Dok umente <- -)/Wa rnhinw eise /Si cherhei t - 230 V @ 18\m od_130 260 681 6750_15 .docx @ 1 03308 @ @ 1
Warning
Electric voltage!
Dangerous currents flow through the body when coming into direct or
indirect contact with live components.
This can result in electric shock, burns or even death.
Disconnect the mains power supply prior to installation and/or
disassembly!
Permit work on the 110-240 V supply system to be performed only by
specialist staff!
Pos: 8 /B usc h-Ja eger (N eust rukt ur)/ Modul -St ruktu r/Onli ne-D oku ment ation /Übe rschri ften (--> Für all e Dok ument e < --)/ 1. Eb ene/A - F/B estim mun gsgemä ßer G ebrau ch @ 18\mod _13 027 6332131 6_1 5.do cx @ 103483 @ 1 @ 1
2 Intended use
Pos: 9 /D inA4 - Anl eitun gen Online /Inh alt /KNX /Doo rEntry /832 20-A P- xxx/B esti mmu ngsg emaes se r Ge brauc h - 83 220 -AP-xx x-500 @ 2 0\mo d_1324 561 168 699 _15. docx @ 11 272 8 @ @ 1
The M22344-W is an integral part of the ABB-Welcome door entry system and operates
exclusively with components from this system. The device must only be installed in dry
indoor rooms.
Pos: 10 /B us ch-J aeg er (Neus truk tur )/M odul -Strukt ur/O nline -Dok ume ntati on/Ü bers ch rifte n (--> Fü r alle Doku men te <-- )/1. E bene /U - Z/U mwelt @ 18\mod _13 026 141 58967_1 5.d ocx @ 103 383 @ 1 @ 1
3 Environment
Pos: 11 /B usch-J aeg er (Neus truk tur )/Modul -S trukt ur/O nline -Doku me ntatio n/U mw elt (--> Für all e D oku mente <--)/H inwei s e/Hinw ei s - U mwelt - Hinw eis Elek troge räte @ 1 8\mod_1 302 763 973 434_15. docx @ 10 350 0 @ @ 1
Consider the protection of the environment!
Used electric and electronic devices must not be disposed of with
household waste.
The device contains valuable raw materials that can be recycled.
Therefore, dispose of the device at the appropriate collecting
facility.
Pos: 12 / Di nA 4 - A nleit u ngen Onl in e/Ueb ersc hrift en/2 ./A BB Gera ete @ 19 \mo d_1 323 162 843 832_15. docx @ 11 087 5 @ 2 @ 1
3.1 ABB devices
Pos: 13 /B us ch-J aeger (Neus truk tur )/Modul -S trukt ur/O nline -Doku me ntatio n/Umw el t (--> F ür all e Doku me nte <-- )/Hinw eis e/Hinw eis - U mwelt - AB B El ektroger äte @ 19\ mod_1 3231 627 45839_ 15.d ocx @ 110 867 @ @ 1
All packaging materials and devices from ABB bear the markings and test seals for
proper disposal. Always dispose of the packaging material and electric devices and their
components via an authorized collection facility or disposal company.
ABB
-Welcome
ABB products meet the legal requirements, in particular the laws governing electronic
and electrical devices and the REACH ordinance.
(EU-Directive 2002/96/EG WEEE and 2002/95/EG RoHS)
(EU-REACH ordinance and law for the implementation of the ordinance (EG)
No.1907/2006)
ABB
-Welcome
Pos: 18 /D i nA4 - A nleit ungen Onli ne/ Ueb ersc hrift en/1 ./Bedi enun g @ 18\m od_130 261 392 416 5_15 .docx @ 1033 65 @ 1 @ 1
4 Operations
Pos: 19 /D i nA4 - A nl eitu ngen Onlin e/U eb ersc hrift en/2 ./Nor male r B etri eb @ 18 \mo d_1 302 768 8209 65_ 15. docx @ 10 3540 @ 2 @ 1
4.1 Standard operations
Pos: 20 /D i nA4 - A nl eitu ngen Onlin e/U ebersc hrift en/3 ./B edie nele men te @ 20\ mod_13 232 6022 055 9_1 5.do cx @ 1 116 47 @ 3 @ 1
4.1.1 Control elements
Pos: 21 /D i nA4 - A nleitu ngen Onlin e/In halt/K NX /Do orEnt ry/83 220 -AP -xxx/Be di enel emente - 8322 0-A P-xxx @ 18\ mo d_13032 128 536 05_15. doc x @ 103 673 @ @ 1
Fig. 1 Control elements
1
3 4 5 6 72
ABB
-Welcome
No. Functions
1 4.3" Color display
2 Communication button
2A For incoming call, press this button to activate the communication
within 30 seconds and press it again to end the call.
2B In standby mode, press this button to enter the communication menu.
If the LED flashes slowly, this means an incoming call.
If the LED illuminates, this means that a conversation is in progress.
If the LED flashes rapidly, it means system is busy.
3 Unlock button
3A Press this button to open the door at any time.
4 Surveillance button
4A In standby mode, press this button to survey the default outdoor station.
4B While the display is on, press this button to the survey the next outdoor
station. (This function is available depending on the installation type.)
4C While the display is on, hold this button to take a snapshot.
4D In standby mode, if the LED flashes, press this button to display the
"History" record.
If the LED flashes slowly, this represents a notification of a missed
call.
5 Mute button
5A In standby mode, press this button to mute ringtone of the indoor
station.
5B In standby mode, hold the button to mute ringtone of all indoor stations
in the apartment.
5C Press this button to reject incoming call.
5D During the conversation, press this button to mute microphone.
The LED illuminates to indicate mute status.
6 Programmable button 1
6A Release the second lock connected with an outdoor station (default
function).
6B *Programmable button for additional functions, e.g. call to guard unit,
7 System setting button
Enter the system setting menu for various functions of the device.
If the LED flashes rapidly, it means that setting is busy.
*For use of those buttons, please contact your electrical installer.
Pos: 22 /B usc h-Jaeg er (Neus truk tur)/M odul -Strukt ur/O nli ne-Dok ume ntatio n/S teuer mod ule - Onl ine-D ok umentati on ( --> F ür alle Dok ume nte <--)/ +++++ +++++ ++ S eiten umbruch + +++++ +++++ + @ 9\m od_126 8898 668 093_0. docx @ 521 49 @ @ 1
ABB
-Welcome
Pos: 26 /D i nA4 - A nl eitu ngen Onlin e/U ebersc hrift en/2 ./B edie nakti onen @ 2 0\m od_ 1323 262294 281 _15. docx @ 11 191 1 @ 2 @ 1
4.2 Control actions
Pos: 27 /D i nA4 - A nleitu ngen Onlin e/Ueb ersc hrif ten/ 3./S pr ech- und Vi deov erbindu ng @ 20\ mod_13 232 6236 870 0_15.do cx @ 1119 27 @ 3 @ 1
4.2.1 Incoming call/in a call
Pos: 28 /D i nA4 - A nleit ungen Onli ne/I nhal t/KN X/Do orEnt ry/ 83220 -A P-xxx/ Sp rech - und Vi de overbi nd ung - 8 3220-A P-xx x @ 20\ mo d_1 3232 623418 52_ 15.d ocx @ 111 919 @ @ 1
Fig. 2 Incoming call/in a call
During a call, the following functions are available:
No. Functions
1 Press this button to accept incoming call. In a call, press this button to end
the call.
2 Press this button to open the door where the call is from.
3-A Press this button to survey the analog camera of the outdoor station if
there is one.
3-B Hold this button to take a snapshot.
4 Press this button to mute the ringtone of an incoming call. In a call, press
this button to mute the microphone.
5-A Press this button to activate the function of the programmable button.
5-B If the function "release second lock" or "control switch actuator" is assigned
to the programmable button, press this button to activate the function.
6-A
6-B
Press this button to enable or disable the full-screen function.
Hold this button to enter the brightness and volume setttings menu.
7 Time left of the connection.
8 Number of outdoor stations
Pos: 29 /B usc h-Jaeg er (Neus truk tur)/M odul -Strukt ur/O nli ne-Dok ume ntatio n/S teuer mod ule - Onl ine-D ok umentati on ( --> F ür alle Dok ume nte <--)/ +++++ +++++ ++ S eiten umbruch + +++++ +++++ + @ 9\m od_126 8898 668 093_0. docx @ 521 49 @ @ 1
30s
Outdoor 1
1
3
6
7
8
2 4
5
ABB
-Welcome
Pos: 30 /D i nA4 - A nl eitu ngen Onlin e/U eb ersc hrift en/3 ./T uer oef f nen @ 2 0\mo d_1 323 263 277 453_15. doc x @ 11193 5 @ 3 @ 1
4.2.2 Display and volume settings during a call
Pos: 31 /D i nA4 - A nlei tu ngen Onl in e/In halt/K NX/ Do orEnt ry/83 220 -AP -xxx/ Tue r oeff nen - 832 20-AP-x x x @ 20\ mod_ 132 326 795 847 9_15.doc x @ 1121 09 @ @ 1
Fig. 3 Display and volume settings during a call
Hold button for 3s to enter the display and volume setttings menu during a call or
conversation. The following functions are available.
No. Functions
1 Navigation buttons ( up, down, confirm, cancel etc.)
2 Press the navigation buttons as needed.
3 Speech volume (can only be adjusted during conversation).
4 Saturation
5 Brightness
6 Value set
Pos: 32 /B usc h-Jaeg er (Neus truk tur)/M odul -Strukt ur/O nli ne-Dok ume ntatio n/S teuer mod ule - Onl ine-D ok umentati on ( --> F ür alle Dok ume nte <--)/ +++++ +++++ ++ S eiten umbruch + +++++ +++++ + @ 9\m od_126 8898 668 093_0. docx @ 521 49 @ @ 1
120s
Outdoor 1
2
4
5
6
1
2
3
ABB
-Welcome
Pos: 33 /D i nA4 - A nl eitu ngen Onlin e/U eb ersc hrift en/3 ./S tumm sc hal te n @ 2 0\mod_ 132 326 360 7142 _15 .docx @ 1 119 51 @ 3 @ 1
Pos: 66 /B usc h-Jaeg er (Neus truk tur)/M odul -Strukt ur/O nli ne-Dok ume ntatio n/S teuer mod ule - Onl ine-D ok umentati on ( --> F ür alle Dok ume nte <--)/ +++++ +++++ ++ S eiten umbruch + +++++ +++++ + @ 9\m od_126 8898 668 093_0. docx @ 521 49 @ @ 1
4.2.3 Communication menu
Pos: 31 /D i nA4 - A nlei tu ngen Onl in e/In halt/K NX/ Do orEnt ry/83 220 -AP -xxx/ Tue r oeff nen - 832 20-AP-x x x @ 20\ mod_ 132 326 795 847 9_15.doc x @ 1121 09 @ @ 1
4.2.3.1 Overview
Press button to enter the communication menu. The following functions are available:
No. Functions
1 Call to guard unit
-Call guard unit directly.
2 Switch actuator
-Activate the existing actuator list.
4.2.3.2 Call to guard unit
Fig. 4: Call to guard unit
CALL GUARD UNIT
Call Guard Unit
ABB
-Welcome
4.2.3.3 Switch actuator
Fig. 5: Switch actuator
Set the actuator list in the “system settings-switch actuatormenu first.
After choosing a list, press button to enable the lock or light, which is connected with the
switch actuator.
SWITCH ACTUATOR
Actuator 1 (001)
ABB
-Welcome
4.3 Settings
4.3.1 Overview
Press button to enter the system settings menu. The following functions are available:
No. Functions
1 Switch actuator
-Set the actuator list in this menu.
2 Program button
-Set functions for programmable buttons.
3 Ringtone
-Set the ringtone for outdoor bells, indoor bell or others.
4 Volume
-Set volume of ringtone.
5 Date and time
-Set different times.
6 Other settings
-Other settings, e.g. auto full screen.
7 History
-View all communication entries in the menu, e.g. received calls, missed
calls.
8 Language
-Set the local language.
9 Information
10 Reset factory default.
Pos: 27 /D i nA4 - A nleitu ngen Onlin e/Ueb ersc hrif ten/ 3./S pr ech- und Vi deov erbindu ng @ 20\ mod_13 232 6236 870 0_15.do cx @ 1119 27 @ 3 @ 1
ABB
-Welcome
4.3.2 Switch actuator settings
Fig. 6: Switch actuator settings
No. Functions
1 Existing switch actuator list: Press button to modify the settings.
2 Add a new actuator list. A total of 10 switch actuator lists can be added.
3 Enter to change target address with “+” or “-” button from 001 to 199.
4 Rename the switch actuator list:
Scroll through letters of the alphabet or numbers one by one with “+” or
“-” button
3
4
SWITCH ACTUATOR
Actuator 1 (001)
Add New
Target Address
Rename
002
light
Save Cancel
SWITCH ACTUATOR
2
1
Add a new list
ABB
-Welcome
4.3.3 Program button settings
Fig. 7: Program button settings
No. Functions
1 Set functions for the program button, e.g. releasing 2nd-lock, calling guard
unit, enabling the switch actuator.
*Only the switch actuator list can be assigned to the program button.
Button 1
Release 2nd-Lock
PROGRAM BUTTON
1
ABB
-Welcome
4.3.4 Ringtone settings
Fig. 8: Ringtone
No. Functions
1 Select the bell sound for the default outdoor station.
2 Select the bell sound for other outdoor stations.
3 Select the bell sound for the apartment door.
4 Select the bell sound for others, e.g. a call from the guard unit.
1
Default Outdoor
Other Outdoors
RING TONE
Ring Tone 1
Ring Tone 2
2
Doorbell
Ring Tone 3
Others
Ring Tone 4
3
4
ABB
-Welcome
4.3.5 Volume settings
Fig. 9: Volume settings
No. Functions
1 Set the volume of bell sound.
2 Enable/disable the feedback tone that sounds when the touch button is
pressed.
3 The ringtone can be set as fixed or cycled.
1
Ringtone Volume
Touchbutton Tone
VOLUME
Volume 3
2
Repeated Tone
3
ABB
-Welcome
4.3.6 Date and time settings
Fig. 10: Date and time settings
No. Functions
1 Set the date.
2 Set the time.
3 Enable/disable the summer time function.
1
Date(YYYY-MM-DD)
Time
DATE AND TIME
2013
2
08
Summer Time
00
-
01
-
01
3
ABB
-Welcome
4.3.7 Other settings
Fig. 11: Other settings
No. Functions
1 Enable/disable the auto full screen function.
2 Enable/disable the auto-snapshot function.
3 Enable/disable the missed call function. ( flashes when there is a missed
call).
1
Auto Full Screen
Auto
-
snapshots
OTHER SETTINGS
2
Missed
3
ABB
-Welcome
4.3.8 History review
Fig. 12: History review
No. Functions
1 Up to 100 events can be recorded in the history menu.
-If the snapshot function is enabled, an icon is diplayed.
-Date, time and type of the event are recorded together with the
snapshot.
- Directions: means dialing calls
means receiving calls
means missed calls
2 Press this button to view details of this event.
HISTORY
1/2
Outdoor -1
1/63
2013-03-21
16:45
Outdoor - 1
2013-03-21
16:45
Outdoor - 1
2013-03-21
14:24
Outdoor - 1
1
2
3
ABB
-Welcome
Two photos are always made when a visitor rings the bell.
3 Press this button to delete a record item.
ABB
-Welcome
4.3.9 Language settings
Fig. 13: Language settings
4.3.10 Information
Fig. 14: Information for the indoor station. (Scan the QR code to get detailed instruction for
indoor station.)
English
LANGUAGE
Flash Version: V1.02_151210_US
INFORMATION
MCU Version: V1.02_151210_US
M/S: Master
Default Outdoor: 1
Indoor St. Add.: 001
/