ABB 83327-500 User manual

  • Hello! I am an AI chatbot trained to assist you with the ABB 83327-500 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
VER:V1.2 28.04.2017
ABB-Welcome
Pos: 2 /D inA4 - Anl eit ungen Onli ne/I nhal t/KN X/Doo rEnt ry/ 83220-A P- xxx/ Tit elblat t - 832 20-A P-xxx - AB B @ 1 9\m od_132 3249 806 476 _15.doc x @ 11 108 4 @ @ 1
83327-500
Camera interface
=== E nde der Lis te für Tex tma rke C over == =
ABB
-Welcome
| — 2 —
Pos: 4 /B usc h-Ja eger (N eust rukt ur)/ Modul-S t ruktu r/Onli ne-D oku ment ation /Inh altsve rzeic hni s (--> Fü r alle Doku men te <-- )/In haltsve rzeic hnis @ 19\ mod _13206 490 4438 6_15.d ocx @ 109 653 @ @ 1
1 Safety ....................................................................................................... 3
2 Intended use ............................................................................................. 3
3 Environment .............................................................................................. 3
3.1 ABB devices ............................................................................. 3
4 Operation .................................................................................................. 5
4.1 Control elements ....................................................................... 5
4.2 Operating modes ...................................................................... 6
4.2.1 Mode=1, works as an independent outdoor station ..................... 6
4.2.2 Mode=2, works associated with outdoor station .......................... 7
4.2.3 Mode=3, works associated with guard unit ................................. 8
4.2.4 Mode=4, programming mode ..................................................... 9
4.3 Programming mode ................................................................. 10
4.4 With and without permanent power supply ............................... 11
4.5 Video signal from third party DVR ............................................ 12
4.6 Video signal to be stored to third party DVR ............................. 13
5 Technical data......................................................................................... 14
5.1 Overview table ........................................................................ 14
5.2 Device connection diagram...................................................... 14
6 Mounting/Installation ............................................................................... 15
6.1 Requirements for the electrician............................................... 15
6.2 General installation instructions ............................................... 16
6.3 Mounting ................................................................................. 17
6.3.1 Surface-mounted installation ................................................... 17
6.3.2 Flush-mounted installation ....................................................... 17
6.3.3 DIN installation ........................................................................ 17
=== E nde der Liste für Textmarke TO C == =
ABB
-Welcome
| — 3 —
Pos: 6 /B usc h-Ja eger (N eust rukt ur)/ Modul-S t ruktu r/Onli ne-D oku ment ation /Übe rschri ften (--> Für alle D okum ent e <--)/ 1. Eb ene/S - T/S icher heit @ 18\ mod _13 026127 917 90_ 15.d ocx @ 103 357 @ 1 @ 1
1 Safety
Pos: 7 /B usc h-Jaege r (N eust rukt ur)/Mo dul-St ruktu r/Onli ne-D oku ment ation /Si cher heit (-- > Für al le Dok umente <- -)/Wa rnhinw eise /Si cherhei t - 230 V @ 18\m od_130 260 681 6750_15 .docx @ 1 03308 @ @ 1
Warning
Electric voltage!
Dangerous currents flow through the body when coming into direct or
indirect contact with live components.
This can result in electric shock, burns or even death.
Disconnect the mains power supply prior to installation and/or
disassembly!
Permit work on the 110-240 V supply system to be performed only by
specialist staff!
Pos: 8 /B usc h-Ja eger (N eust rukt ur)/ Modul -St ruktu r/Onli ne-D oku ment ation /Übe rschri ften (--> Für all e Dok ument e < --)/ 1. Eb ene/A - F/B estim mun gsgemä ßer G ebrau ch @ 18\mod _13 027 6332131 6_1 5.do cx @ 103483 @ 1 @ 1
2 Intended use
Pos: 9 /D inA4 - Anl eitun gen Online /Inh alt /KNX /Doo rEntry /832 20-A P- xxx/B esti mmu ngsg emaes se r Ge brauc h - 83 220 -AP-xx x-500 @ 2 0\mo d_1324 561 168 699 _15. docx @ 11 272 8 @ @ 1
This device integrates analog camera into the ABB-Welcome door entry system. Up to 4
analog cameras can be connected to 1 camera interface. Each external camera is
powered independently.
Pos: 10 /B us ch-J aeg er (Neus truk tur )/M odul -Strukt ur/O nline -Dok ume ntati on/Ü bers ch rifte n (--> Fü r alle Doku men te <-- )/1. E bene /U - Z/U mwelt @ 18\mod _13 026 141 58967_1 5.d ocx @ 103 383 @ 1 @ 1
3 Environment
Pos: 11 /B usch-J aeg er (N eus truk tur)/M odul -St rukt ur/Onl ine -Doku me ntatio n/Umw el t (--> Für all e Doku me nte <--)/Hi nweis e/H inw eis - U mwelt - Hinw eis El ektroge räte @ 1 8\mod_1 302 763 973 434 _15.doc x @ 10 350 0 @ @ 1
Consider the protection of the environment!
Used electric and electronic devices must not be disposed of with
household waste.
The device contains valuable raw materials that can be recycled.
Therefore, dispose of the device at the appropriate recycling
facility.
Pos: 12 / Di nA 4 - A nleit u ngen Onl in e/Ueb ersc hrift en/2 ./A BB Gera ete @ 19 \mod_1 323 162 843 832_ 15. docx @ 11 0875 @ 2 @ 1
3.1 ABB devices
Pos: 13 /B us ch-J aeger (Neus truk tur )/Modul -S trukt ur/O nline -Doku me ntatio n/Umw el t (--> F ür all e Doku me nte <-- )/Hinw eis e/Hinw eis - U mwelt - ABB Elekt roger äte @ 19\mo d_1 3231 627458 39_ 15.d ocx @ 110867 @ @ 1
ABB
-Welcome
| — 4 —
All packaging materials and devices from ABB bear the markings and test seals for
proper disposal. Always dispose of the packaging material and electric devices and their
components via an authorized recycling facilities or disposal companies.
ABB products meet the legal requirements, in particular the laws governing electronic
and electrical devices and the REACH ordinance.
(EU-Directive 2002/96/EG WEEE and 2002/95/EG RoHS)
(EU-REACH ordinance and law for the implementation of the ordinance (EG)
No.1907/2006)
ABB
-Welcome
| — 5 —
Pos: 18 /D i nA4 - A nleit ungen Onli ne/ Ueb ersc hrift en/1 ./Bedi enun g @ 18\m od_130 261 392 416 5_15 .docx @ 1033 65 @ 1 @ 1
4 Operation
Pos: 19 /D i nA4 - A nl eitu ngen Onlin e/U eb ersc hrift en/2 ./Nor male r B etri eb @ 18 \mo d_1 302 768 8209 65_ 15. docx @ 10 3540 @ 2 @ 1
4.1 Control elements
Pos: 20 /D i nA4 - A nl eitu ngen Onlin e/U ebersc hrift en/3 ./B edie nele men te @ 20\ mod _13 232 6022 055 9_15. doc x @ 1 11647 @ 3 @ 1
Pos: 21 /D i nA4 - A nleitu ngen Onlin e/In halt/K NX /Do orEnt ry/83 220 -AP -xxx/Be di enel emente - 8322 0-A P-xxx @ 18\ mo d_13032 128 536 05_15. doc x @ 103 673 @ @ 1
Fig. 1: Overview of control buttons
No. Functions
1
Bus in
2
Bus out
3
CVBS out
4
Switch on camera power supply.
For details, please see Chapter 4.4 With & Without permanent power
supply
5
Working mode
There are 4 modes for the camera interface, For details, please see
Chapter 4.3 Operation mode.
6 Set the address of the associated devices.
7 Set the address of the camera interface.
8
Operating status notification LED
-Green: ready for operation
-Orange: in setting mode
-Red: fault
9
Dip switch to switch on/off the video channel.
10
Program button to enter the programming mode.
11
4 video in. (supports CVBS signal input)
Pos: 22 /B usc h-Jaeg er (Neus truk tur)/M odul -Strukt ur/O nli ne-Dok ume ntatio n/S teuer mod ule - Onl ine-D ok umentati on ( --> F ür alle Dok ume nte <--)/ +++++ +++++ ++ S eiten umbruch + +++++ +++++ + @ 9\m od_126 8898 668 093_0. docx @ 521 49 @ @ 1
ABB
-Welcome
| — 6 —
Pos: 26 /D i nA4 - A nl eitu ngen Onlin e/U ebersc hrift en/2 ./B edie nakti onen @ 2 0\m od_1323 262 294 281 _15. docx @ 11 191 1 @ 2 @ 1
4.2 Operating modes
Pos: 71 /D i nA4 - A nl eitu ngen Onlin e/U ebersc hrift en/3 ./A bschl ussw ide rsta nd @ 19\ mod_13 219 5807 990 6_1 5.do cx @ 1100 83 @ 3 @ 1
Pos: 72 / Di nA 4 - A nlei tu ngen O nlin e/In hal t/KN X/Do orE nt ry/B edie nun g/Abs chl ussw ide rsta nd s etz en 83 220 -A P-xx x @ 19\ mod _13 1072339 236 9_1 5.do c x @ 1 078 41 @ @ 1
4.2.1 Mode=1, works as an independent outdoor station
Fig. 2: Mode=1, works as an independent outdoor station
Rotary Value Note
Mode 1 Camera interface works as an independent camera interface.
Addr null ——
ID 2
ID starts from 1 to 9 sequentially, and should not be the same
address of camera interface or other camera interface.
Pos: 74 /D i nA4 - A nlei tu ngen Onl in e/In halt/K NX/D o orEnt ry/Bedi e nung/ Mast er/S lave S c halte r setz en 832 20-A P-xxx @ 1 9\m od_1 310 723320 966 _15. docx @ 10 783 3 @ @
Dip Switch 1-4 Turn to ON when a camera is connected.
Capacity
Each camera interface supports 4 analog cameras.
A total 9 camera interfaces (mode=1) in one system.
Operation
Press to view the cameras individually during surveillance.
ABB
-Welcome
| — 7 —
4.2.2 Mode=2, works associated with outdoor station
Fig. 3: Mode=2, works associated with outdoor station
Rotary Value Note
Mode 2 Camera interface work associated with outdoor station.
Addr 1 Address of the associated outdoor station, from 1-9.
ID 1 ID can be set from 1-9, and should be unique.
Dip Switch 1-4 Turn to ON when a camera is connected.
Capacity
Each camera interface supports 4 analog cameras.
A total of 15 cameras can be associated with each outdoor station (including 2 built-in cameras in
outdoor station).
Operation
Press to view the cameras individually during surveillance.
Pos: 74 /D i nA4 - A nlei tu ngen Onl in e/In halt/K NX/D o orEnt ry/Bedi e nung/ Mast er/S lave S c halte r setz en 832 20-A P-xxx @ 1 9\m od_1 310 723320 966 _15. docx @ 10 783 3 @ @
ABB
-Welcome
| — 8 —
4.2.3 Mode=3, works associated with guard unit
Fig. 4: Mode=3, works associated with guard unit
Rotary Value Note
Mode 3 Camera interface work associated with guard unit.
Addr 1 Address of guard unit, from 1-9.
ID 1 ID can be set from 1-9, and should be unique.
Dip Switch 1-4 Turn to ON when a camera is connected.
Capacity
Each camera interface supports 4 analog cameras.
A total of 15 cameras can be associated with each guard unit.
Operation
During communication, image can be sent from guard unit to indoor station by pressing the
"Enable" button.
Pos: 75 /B usc h-Jaeg er (Neus truk tur)/M odul -Strukt ur/O nli ne-Dok ume ntatio n/S teuer mod ule - Onl ine-D ok umentati on ( --> F ür alle Dok ume nte <--)/ +++++ +++++ ++ S eiten umbruch + +++++ +++++ + @ 9\m od_126 8898 668 093_0. docx @ 521 49 @ @ 1
ABB
-Welcome
| — 9 —
4.2.4 Mode=4, programming mode
Fig. 5: mode=4, programming mode
Rotary Value Note
Mode 4 Camera interface works in programming mode.
Addr null
Camera interface mode, camera interface address and associated device
address can all be programmed with software.
In mode=4, besides camera interface and guard unit, camera interface
can also be associated with video indoor station.
If camera interface is associated with video indoor station, ID should start
from 1 to 9 sequently.
For details, see Chapter 4.3 Programming mode.
ID null
Dip Switch 1-4 Turn to ON when a camera is connected.
Capacity
Each camera interface supports 4 analog cameras. Each camera can be associated with
different devices (i.e., outdoor station, guard unit, video indoor station).
A total of 36 cameras can be associated with each video indoor station. Each camera can be
associated with 250 indoor stations.
ABB
-Welcome
| — 10 —
4.3 Programming mode
start
1. Long press “Prog” button for 3s to
enter programming mode
2. Choose cameras to set by dip switch
V1/V2/V3/V4
4. Set the working mode by R1
Mode=1, Camera interface works as an independent outdoor station.
Mode=2, Camera interface works associated with outdoor station.
Mode=3, Camera interface works associated with guard unit.
Mode=4, Camera interface works associated with indoor station
3. Assign the address of the camera
interface by R3
5. Short-press "Prog" button to save current setting
6. Set the address of the associated
device by these three rotary switches
(R1&R2&R3)
Address=R1*100+R2*10+R3
continue to
program
8. Long press “
Prog
” button
3s
to exit
programming mode
End
7. Short-press "
Prog
" button to save
current setting
N
Y
R1 R2 R3
ABB
-Welcome
| — 11 —
4.4 With and without permanent power supply
+
-
12V
+
-
12V
Camera with permanent power supply Camera without permanent power supply
ABB
-Welcome
| — 12 —
4.5 Video signal from third party DVR
Fig. 6: Video signal from third party DVR
Note:
1) DVR output can be one of the inputs for camera interface in modes 1, 2, 3, and 4.
2) Each camera Interface supports 4 DVR singnals.
DVR
ABB
-Welcome
| — 13 —
4.6 Video signal to be stored to third party DVR
Fig. 7: Video signal to be stored to third party DVR
Note:
1) Camera interface sends video to video indoor station and also to DVR/TV through the
CVBS output port.
2) Each camera interface supports 1 CVBS output.
3) After connecting CVBS output to DRV/TV, there are two options for sending video to
DVR:
-Camera interface mode=2, video outdoor station calls video indoor station.
-Camera interface mode=3, "Enable" button is pressed at guard unit.
4) Camera interface doesn’t send video to DVR/TV during video Indoor station
surveillance.
Pos: 75 /B usc h-Jaeg er (Neus truk tur)/M odul -Strukt ur/O nli ne-Dok ume ntatio n/S teuer mod ule - Onl ine-D ok umentati on ( --> F ür alle Dok ume nte <--)/ +++++ +++++ ++ S eiten umbruch + +++++ +++++ + @ 9\m od_126 8898 668 093_0. docx @ 521 49 @ @ 1
DVR
ABB
-Welcome
| — 14 —
Pos: 76 / Di nA 4 - A nleit u ngen Onl in e/Ueb ersc hrift en/1 ./T echnis c he D aten @ 18 \mo d_1 302 615 863 001 _15. docx @ 10 341 6 @ 1 @ 1
5 Technical data
Pos: 77 /D i nA4 - A nl eitu ngen Onli ne/ In halt/KN X/D o orEnt ry/83 220 -AP -xxx/ Tech nis che Date n - 832 20-A P-x xx @ 18\ mod_ 130 321 285 4559 _15 .docx @ 1 037 05 @ @ 1
5.1 Overview table
Designation Value
Single-wire clamps 2 x 0.28 mm
2
- 2 x 0.75 mm
2
Fine-wire clamps 2 x 0.28 mm
2
- 2 x 0.75 mm
2
Bus voltage 20-30 V DC
Protection IP 30
Operating temperature
-25 - +55
Video input 1Vp-p, PAL/NTSC
Video output 1Vp-p@75Ω, PAL/NTSC
Camera interface to camera
Coax cable, Max 100 metres
other cables, 10-50 metres
Size
77 mm x 61 mm x 25 mm
5.2 Device connection diagram
Pos: 78 /B usc h-Jaeg er (Neus truk tur)/M odul -Strukt ur/O nli ne-Dok ume ntatio n/S teuer mod ule - Onl ine-D ok umentati on ( --> F ür alle Dok ume nte <--)/ +++++ +++++ ++ S eiten umbruch + +++++ +++++ + @ 9\m od_126 8898 668 093_0. docx @ 521 49 @ @ 1
ABB
-Welcome
| — 15 —
Pos: 79 /B usch-J aeg er (Neus truk tur )/Modul -Strukt ur/O nli ne-D oku ment atio n/Übe rsch rifte n ( --> Fü r alle Doku men te < --)/1. E bene /M - O/ Mont age / Ins tal latio n @ 18\ mod _130261 396 611 1_1 5.do cx @ 1 033 73 @ 1 @ 1
6 Mounting/Installation
Pos: 80 /B usc h-Jaeg er (Neus truk tur)/M odul -Struk tur/O nli ne-D oku mentati on/S iche rheit (--> Für alle D oku ment e <--) /War nhinwei s e/Siche rheit - Nie ders pannun gs- und 230 V-Leit ung en @ 18\ mod _13 026178 214 91_1 5.doc x @ 103 465 @ @ 1
Warning
Electric voltage!
Dangerous currents flow through the body when coming into direct or
indirect contact with live components.
This can result in electric shock, burns or even death.
Disconnect the mains power supply prior to installation and/or
disassembly!
Permit work on the 110-240 V supply system to be performed only
by specialist staff!
Pos: 81 /B usch-J aeg er (N eus truk tur)/M odul -S trukt ur/O nline -Doku me ntatio n/S iche rheit (- -> Fü r alle D oku ment e <--) /War nhinwei s e/Si che rheit - Fachk enn tniss e @ 18 \mo d_1 302774 384 017_ 15. docx @ 10 3564 @ 2 @ 1
6.1 Requirements for the electrician
Warning
Electric voltage!
Install the device only if you have the necessary electrical engineering
knowledge and experience.
Incorrect installation endangers your life and that of the user of the
electrical system.
Incorrect installation can cause serious damage to property, such
as a fire.
The minimum necessary expert knowledge and requirements for the
installation are as follows:
Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1. Disconnect from power;
2. Secure against being re-connected;
3. Ensure there is no voltage;
4. Connect to earth;
5. Cover or barricade adjacent live parts.
Use suitable personal protective clothing.
Use only suitable tools and measuring devices.
Check the type supply network (TN system, IT system, TT system)
to secure the following power supply conditions (classic connection
ABB
-Welcome
| — 16 —
to ground, protective earthing, necessary additional measures,
etc.).
Pos: 82 /D i nA4 - A nl eitu ngen Onlin e/I nhal t/KN X/D oorE nt ry/M onta ge/ Mont age hinweis e - A llg emei n @ 1 9\m od_ 131 056367 047 8_15 .docx @ 1 077 43 @ 2 @ 1
6.2 General installation instructions
Terminate all branches of the wiring system via a connected bus device (e.g.,
indoor station, outdoor station, system device).
Do not install the system controller directly next to the bell transformer and other
power supplies (to avoid interference).
Do not install the wires of the system bus together with 100-240 V wires.
Do not use common cables for the connecting wires of the door openers and wires
of the system bus.
Avoid bridges between different cable types.
Use only two wires for the system bus in a four-core or multi-core cable.
When looping, never install the incoming and outgoing bus inside the same cable.
Never install the internal and external bus inside the same cable.
ABB
-Welcome
| — 17 —
6.3 Mounting
Pos: 85. 1 /D inA4 - Anl eit ung en O nline/I nhal t/ KNX /DoorE nt ry/ 83220-A P-xx x /Mo ntage - Mo dule/ Mon tag e - Mon tage dos e -- 83 220 -AP -xxx @ 19\ mod _132 325 040 6848_1 5.doc x @ 1 110 98 @ @ 1
6.3.1 Surface-mounted installation
6.3.2 Flush-mounted installation
6.3.3 DIN installation
Pos: 83 /B usc h-Jaeg er (Neus truk tur)/M odul -Strukt ur/O nli ne-Dok ume ntatio n/S teuer mod ule - Onl ine-D ok umentati on ( --> F ür alle Dok ume nte <--)/ +++++ +++++ ++ S eiten umbruch + +++++ +++++ + @ 9\m od_126 8898 668 093_0. docx @ 521 49 @ @ 1
ABB
-Welcome
Pos: 95 /Di nA4 - A nleit ungen Onli ne/In halt /KNX /Do orEnt ry/P roj ektier ung -Merkbl at t/Pr ojekti erP os: 9 7 /Busc h-Ja ege r (N eust ruktu r)/ Modul-S tr uktu r/Onli ne-D oku ment ation /Rück seit en (-- > Für alle Dok um ente <--)/R ücks eit e - Bus ch-J aeg er - Al lgem ein @ 20\ mod _13 273200 748 86_1 5.d ocx @ 137 103 @ @ 1
Notice
=== E nde der Lis te für Tex tma rke Ba ckcove r ===
We reserve the right to, at any time, make technical changes or changes in the content
of this document without prior notice.
The detailed specifications agreed to at the time of ordering applies to all orders. ABB
accepts no responsibility for possible errors or incompleteness in this document.
We reserve all rights to this document and the topics and illustrations contained therein.
The document and its contents, or excerpts thereof, must not be reproduced,
transmitted or reused by third parties without prior written consent by ABB.
/