3
Business Communications Manager Programmable Analog Interface
The profile should only be removed under guidance from Nortel Support (1-800-nortel support).
Alarms
If your system does not have an analog profile, no new alarms appear on your system. If your
system has an analog profile, the following new alarms can appear.
1.Call 1-800-nortel support to reach an authorized Nortel technician.
2.In the handset interface, press ** Option.
3.Log on by following the voice prompts or the display button options.
4.Enter your password and press OK.
5.Press Next to continue through the screens until you reach the
Profile File screen.
The Profile File screen appears. The Profile status is Y if a profile file
exists.
If the Profile status is N, then no profile file exists on the BCM system
and no further action is required.
6.Press DEL.
The file is removed, and the Profile File status changes to N.
7.To remove the parameters from the interface, perform a warm
restart of the BCM system.
Refer to the Telset Administration Guide for your BCM platform for the
procedure to perform a warm restart.
Table 1 Programmable analog interface alarms
Alarm
number Alarm text Action
382 Market profile does not match
analog profile base market
profile
The market profile you selected in the BCM does not
match the market profile used as a base for the
analog profile file. Either change the BCM market
profile, or change (or delete) the profile file.
383 Profile is corrupt or invalid. You cannot use the profile file you selected. Delete or
replace the profile file.
User ID:_
CANCL BKSP OK
Password:_
CANCL BKSP OK
Profile File: Y
DEL
Profile File: N
DEL