Altronix Trove T1RSH3F8 Installation guide

  • Hello! I am an AI chatbot trained to assist you with the Altronix Trove T1RSH3F8 Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Rev. T1RSH3F8112618
T1RSH3F8
Fully assembled kit includes:
- Trove1R rack enclosure with Altronix/Software House backplane (TSH1R)
- (1) eFlow6NB - Power Supply/Charger
- (1) VR6 - Voltage Regulator
- (1) ACMS8 - Fused Dual Output Access Power Controller
Installation Guide
All registered trademarks are property of their respective owners. More than just power.™
Installing Company: _____________________ Service Rep. Name: __________________________________________
Address: ________________________________________________________ Phone #: _________________________
Access & Power Integration
- 2 - T1RSH3F8
Overview:
Altronix T1RSH3F8 rack kit is pre-assembled and consist of Trove1SH1R enclosure/backplane with factory installed Altronix power sup-
ply/charger and sub-assemblies. This kit also accommodates various combinations of Software House boards for up to eight (8) doors in a
single enclosure.
Configuration Chart:
Altronix
Model
Number
Nominal DC
Output Voltage
Maximum Supply
Current for Main and Aux.
Outputs on Power Supply
board and ACMS8 Access
Power Controller’s outputs
Fail-Safe/
Fail-Secure or
Dry Form “C”
Outputs
120VAC
60Hz
Input
Current
(A)
Current
Per
ACMS8
Output
(A)
Power
Supply
Board
Input
Fuse
Rating
Power
Supply
Board
Battery
Fuse
Rating
ACMS8
Board
Input
Fuse
Rating
ACMS8
Board
Output
Fuse
Rating
[DC] [Aux]
Output
Range
(VDC)
Output
Range
(VDC)
T1RSH3F8
20.19-
26.4
20.19-
26.4
24VDC @ 5.8A 8 3.5 2.5
5A/
250V
10A/
32V
15A/
32V
3A/
32V
Hardware and Accessories:
One (1) tamper switch (Altronix Model TS112 or equivalent).
Cam lock.
Specifications:
Assembling and Attaching Z Bracket Wire Management Accessory (included):
Altronix Trove Rack enclosures include Z Bracket, a convenient and reliable wire management accessory.
1. Carefully unpack Z Bracket. Do not discard hardware (included) (Fig. 1, pg. 2).
2. Attach arms to each other using bolts and lock nuts (Fig. 1a, pg. 2).
3. Attach the hinge brackets to the ends of arms using bolts and nuts positioning them as shown on Fig. 1b, pg. 2.
4. Make sure that all nuts are tightened.
Hardware (included):
Ten (10) bolts and eight (8) lock nuts
Two (2)
Fig. 1
Fig. 1b
Fig. 1a
Agency Listings:
CE European Conformity.
Mechanical:
Black enclosure with ample knockouts for convenient access.
Includes: tamper switch, cam lock and mounting hardware.
Modular 2U standard EIA 19” drawer with
extendable slides up to 48”.
Dimensions (H x W x D): 3.25” x 19.0” x 26.5”
(82.6mm x 482.6mm x 673.1mm).
Available Accessories (not included):
RE2: Rack Mount Battery Enclosure
accommodates up to four (4) 12VDC/7AH batteries.
WM5, WM25, WM100: Magnetic Cable Tie Mounts
(5, 25, 100 counts).
T1RSH3F8 - 3 -
Assembling and Attaching Z Bracket Wire Management Accessory (included) - cont’d:
5. Attach the hinge bracket on the longer side of Z Bracket to the adjustable rail using bolts and lock nuts (included) (Fig. 2, 2a, pg. 3).
6. Attach the hinge bracket on the shorter side of Z Bracket to the rear of the rack enclosure using bolts (included).
Installation Instructions for Trove1R:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having
jurisdiction. Product is intended for indoor use only.
1. Remove backplane from enclosure prior to installing into rack cabinet (do not discard hardware).
2. In order to mount included UL Listed tamper switch (Altronix Model TS112 or equivalent)
turn the enclosure upside down. Punch out the knockout in designated location, on the back
of the unit, from outside of the drawer (Fig. 3, pg. 3). Insert the tamper switch into the
knockout from outside of the drawer with the button facing outwards and spaded connectors
inside the drawer. Connect tamper switch wiring to the Access Control Panel input or the
appropriate UL Listed reporting device. To activate alarm signal open the rack drawer.
3. Slide the rack enclosure into an open 2U location in the four post rack cabinet.
4. Utilizing proper fasteners attach front ears to the rack rails.
5. Attach the rear of the adjustable slides to the rear rails of the rack cabinet with the proper fasteners.
6. Ensure that all internal cofigurations (voltage selection, switch settings, etc.) are completed
before mounting backplane back into Trove rack enclosure.
7. Refer to the eFlow Power Supply/Charger Installation Guide for eFlow6NB and
corresponding sub-assembly Installation Guides for the following models:
ACMS8(CB), VR6 for further instructions.
ACMS8 Operations Instructions:
For more detailed information see ACMS8 Installation Guide, Rev. 090518 (included).
1. Set each output [OUT1] - [OUT8] to route power from power supply 1 or 2 (jumper position [+ PWR1 –],
[+ PWR2 –] or OFF) (Fig. 4, pg. 3). PWR1 = 24VDC; PWR2 = 12VDC.
2. Prior to connecting devices, ensure all output jumpers [OUT1] - [OUT8] are placed in the
proper positions (Fig. 4, pg. 3).
Note: Measure output voltage before connecting devices. This helps avoiding potential damage.
3. For connection options see ACMS8 Installation Guide, Rev. 090518.
Fig. 2
Fig. 2a
Fig. 3
Tamper Switch mounting location
Back of the drawer,
viewed from outside.
PWR1
PWR2
OFF
Fig. 4
- 4 - T1RSH3F8
LED Diagnostics:
eFlow6NB:
Red (DC) Green (AC/AC1) Power Supply Status
ON ON Normal operating condition.
ON OFF Loss of AC. Stand-by battery is supplying power.
OFF ON No DC output.
OFF OFF Loss of AC. Discharged or no stand-by battery. No DC output.
ACMS8:
LED ON OFF
LED 1- LED 8 (Red) Output relay(s) de-energized. Output relay(s) energized.
FACP FACP input triggered (alarm condition). FACP normal (non-alarm condition).
Green Output 1-8 12VDC
Red/Green Output 1-8 24VDC
Terminal Identification:
eFlow6NB:
Terminal Legend Function/Description
L, N Factory connected to line cord (non power-limited).
– DC + Factory set for 12VDC or 24VDC nominal @ 6A continuous output (non power-limited output).
Trigger EOL
Supervised
Fire Alarm Interface trigger input from a short or FACP. Trigger inputs can be normally open, normally closed
from an FACP output circuit (power-limited input).
NO, GND RESET FACP interface latching or non-latching (power-limited).
+ AUX – Auxiliary Class 2 power-limited output rated @ 1A (unswitched).
AC Fail
NC, C, NO
Indicates loss of AC power, e.g. connect to audible device or alarm panel. Relay normally energized when
AC power is present. Contact rating 1A @ 30VDC (power-limited).
Bat Fail
NC, C, NO
Indicates low battery condition, e.g. connect to alarm panel. Relay normally energized when DC power is present.
Contact rating 1A @ 30VDC. A removed battery is reported within 5 minutes. Battery reconnection is reported
within 1 minute (power-limited).
– BAT + Stand-by battery connections. Maximum charge current 1.54A (non power-limited).
ACMS8:
Terminal Legend Function/Description
+ PWR1 12 or 24VDC input from Power Supply.
+ PWR2 12 or 24VDC input from Power Supply.
+ INP1 through
+ INP8
Eight (8) independently controlled Normally Open (NO), Normally Closed (NC),
Open Collector Sink or Wet Input Triggers.
C, NC FACP Dry NC output. With EOL JMP intact, will provide 10k resistance in a normal condition.
GND, RST FACP interface latching or non-latching
GND, EOL EOL Supervised FACP Input terminals
F, + F, R, + R FACP Signaling Circuit Input and Return terminals
Output 1 through
Output 8
NO, C, NC, COM
Eight (8) selectable 5VDC-24VDC independently controlled outputs [Fail-Safe (NC) or Fail-Secure (NO)]
and eight (8) independently controlled Form “C” Relay outputs.
Fuses are rated 2.5A each.
T1RSH3F8 - 5 -
T1RSH3F8: Configuration of Software House Boards:
1. Fasten standoffs onto metal pems configuration (A), (B), or (C) of backplane depending on the access controller (Fig. 5, pg. 5).
2. Position access controller module over corresponding standoffs and fasten screws into standoffs (Fig. 5a, pg. 5).
Note: Software House iSTAR Ultra ACM and iSTAR ACM SE/ACM PRO boards have one (1) USB port each.
Please orient boards in the appropriate position according to the Fig. 5 below.
3. Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models:
Software House Access Controller Pem Mounting
iSTAR Ultra ACM
A
iSTAR ACM SE/ACM PRO
B
I8, R8 or I8-CSI Module
C
Fig. 5
eFlow6NB
AC
L G N
DCAC1
1 min
enable
2 hr.
disable
OFF - 24V
ON - 12V
ON
TRIGGER EOL
SUPERVISED
--- BAT + --- DC +
NC C NO
AC FAIL
NC C NO
BAT FAIL
+ AUX ---
NO GND
RESET
To IEC
connector
OUT1
RISK OF FIRE REPLACE FUSES WITH SAME TYPE AND RATING
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
OUT8
PWR1+
PWR1
PWR1
<-- >
PWR2
PWR1
<-- >
PWR2
PWR1
<-- >
PWR2
PWR1
<-- >
PWR2
PWR1
<-- >
PWR2
INP Logic
NO
<-- >
NC
FACP
EN
<-- >
DIS
FACP
FACP
FACP
EOL JMP
PWR2+
Power 2
Power 1
+INP2--+INP1-- +INP3-- +INP4-- +INP5-- +INP6-- +INP7-- +INP8--
15
3
3
3
3
3
3
3
3
ACMS8
ACMS8CB
1
2
3
4
ON
15
PWR1+
PWR2+
COM--
COM--
5
6
7
8
1
2
3
4
5
6
7
8
ON
ONON
PWR2
OFF
+PWR1-- +PWR2--
NC RST EOL +F +R
C GND GND -F -R
NO C NC COM NO C NC COM
Output 1 Output 2
NO C NC COM NO C NC COM
Output 3 Output 4
NO C NC COM NO C NC COM
Output 5 Output 6
NO C NC COM NO C NC COM
Output 7 Output 8
ACMS8/VR6
USB PORT
A
C
C
C
USB PORT
B
Pem
Standoff
Power Supply or
Sub-Assembly
Backplane
Pan Head
Screw
Fig. 5a
- 6 - T1RSH3F8
Notes:
T1RSH3F8 - 7 -
Notes:
- 8 - T1RSH3F8
Trove1R Enclosure Dimensions (H x W x D):
3.25” x 19.0” x 26.5” (82.6mm x 482.6mm x 673.1mm). Shown with Z Bracket attached.
3.25”
82.3mm
26.5”
673.1mm
19” (482.6mm)
2.4”
61mm
4.57”
116.1mm
11.175” (283.8mm)
R 1.27” (32.3mm)
1” (25.4mm)
0.55” (14mm)
3.62”
92mm
0.1”
2.5mm
1.5”
38.1mm
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
web site: www.altronix.com | e-mail: [email protected] | Made in U.S.A.
IIT1RSH3F8 B06S
MEMBER
/