Warnings and Cautions
The installation of this product should be made by
qualified service personnel and should conform to
all local codes.
WARNING: To prevent serious vision damage,
install the Illuminator so that the distance between
the Illuminator and the closest possible human
contact is no less than 1.22m (4ft).
WARNING: To reduce the risk of electrical shock,
do not remove covers or back of the power supply.
No user-serviceable parts are inside. Refer
servicing to qualified service personnel.
WARNING: This product generates, uses, and can
radiate radio frequency energy and if not installed
and used in accordance with the instructions
manual, may cause interference to radio
communications. It has been tested and found to
comply with the limits for a Class A computing
device pursuant to Part 15 of FCC Rules.
Before You Begin
Unpacking and Inspection
Unpack carefully. This is an electronic product and
should be handled as such. Compare the items
received with the packing list with your order.
Be sure to save:
• The shipping cartons and insert pieces. They
are the safest material in which to make future
shipments of the product.
• The IMPORTANT SAFEGUARDS sheet.
• These Installation and Operating Instructions.
Maintenance
User maintenance of this unit is limited to external
cleaning and inspection. For specific
recommendations refer to the IMPORTANT
SAFEGUARDS sheet packaged with this product.
Installation and Service
If you require information during installation of this
product or if service seems necessary, contact the
American Dynamics Technical Support Center at
800.442.2225. You must obtain a Return
Authorization Number and shipping instructions
before returning any product for service.
Do not attempt to service this product yourself.
Opening or removing covers may expose you to
dangerous voltages or other hazards. Refer all
servicing to qualified personnel.
Description
The American Dynamics series of Infrared
Illuminators provide outstanding results when used
with IR sensitive B/W cameras.
The light produced by the 1020 Series Illuminators
is invisible to the human eye, making these units
excellent for covert operations or where the use of
visible lighting is not possible.
The 1020 Series Illuminator uses 22 rows of LEDs
(Light Emitting Diodes) to consistently produce
peak wavelength infrared light. All 22 rows of
LEDs are wired in parallel to prevent Illuminator
shutdown should one individual LED, or one row of
LEDs, fail.
American Dynamics offers this Illuminator in 30-
watt and 60-watt configurations. The 30-watt
Illuminator provides coverage for indoor and small
outdoor areas where a range of approximately
20m (66ft) is needed. Where greater outside
distance is required, the 60-watt Illuminators
provide coverage up from 35m (115ft) to 55m
(180ft).
Features
Over-voltage shut-off
The 1020 Series Illuminators are designed with
over-voltage circuitry to switch the Illuminator off in
case of voltage surges greater than 15 Vdc. The
unit switches on once the voltage drops below the
15 Vdc level.
Temperature-related shut-off
The 1020 Series Illuminators are designed to shut
off when temperatures exceed 70°C (158°F). The
unit switches on immediately after the temperature
drops below this limit.
Power Supply Selection
A power supply is not included with the 1020
Series Illuminators. The user can select an
independent manufacturer's power supply or
choose the 1040-3060PSA Power Supply
produced by American Dynamics.
When selecting a power supply, bear in mind that
the 1020 Series Illuminators require a stable 13.5
± 0.5 Vdc input.
• A power supply with large voltage output
fluctuations will drive the Illuminator protection
circuitry into shut-down mode.