Danfoss WebAccess for ECL Comfort 200 / 300 Operating instructions

Type
Operating instructions

Danfoss WebAccess for ECL Comfort 200 / 300 enables remote access to your heating system via the internet. With this device, you can monitor and control your heating system from anywhere with an internet connection. The WebAccess data logger is easy to install and set up, and it comes with a user-friendly interface that makes it easy to navigate and use.

With Danfoss WebAccess for ECL Comfort 200 / 300, you can:

  • Monitor your heating system's performance in real time
  • Adjust your heating settings remotely
  • Receive alerts if there are any problems with your heating system
  • Set up multiple users with different access levels

Danfoss WebAccess for ECL Comfort 200 / 300 enables remote access to your heating system via the internet. With this device, you can monitor and control your heating system from anywhere with an internet connection. The WebAccess data logger is easy to install and set up, and it comes with a user-friendly interface that makes it easy to navigate and use.

With Danfoss WebAccess for ECL Comfort 200 / 300, you can:

  • Monitor your heating system's performance in real time
  • Adjust your heating settings remotely
  • Receive alerts if there are any problems with your heating system
  • Set up multiple users with different access levels
VI.KM.H1.02 © Danfoss 06/2005 DH-SMT DN
Installation and configuration
WebAccess
and its modules
for ECL Comfort 200 / 300
2 VI.KM.H1.02 © Danfoss 06/2005 DH-SMT DN
WebAccess
Application principle
DH-SMT DN VI.KM.H1.02 © Danfoss 06/2005 3
WebAccess
Table of Contents
Before you start .......................................................................2
System requirements ..................................................................................... 2
Installation address ......................................................................................... 2
IP addresses* ...................................................................................................... 2
E-mail accounts ................................................................................................. 2
ECL name (menu location 1-4) .................................................................... 2
Heat meters ........................................................................................................ 3
Pulse interface 1 ............................................................................................... 3
Pulse interface 2 ............................................................................................... 3
Pulse interface 3 ............................................................................................... 4
Pulse interface 4 ............................................................................................... 4
Analog interface 1 ........................................................................................... 5
Analog interface 2 ........................................................................................... 5
LON wiring ...............................................................................6
Wiring to the ECL Comfort controller ....................................7
LAN / Ethernet wiring .............................................................9
Powering up ..........................................................................10
Ethernet configuration .........................................................10
Configuration of ECL Comfort controllers ........................... 11
Configuration of modules ....................................................12
Configuration of input channels ..........................................13
IP configuration .....................................................................14
Light emitting diodes ...........................................................15
WAH analog interface ...........................................................16
WAH pulse interface .............................................................17
Screen examples ...................................................................18
2 VI.KM.H1.02 © Danfoss 06/2005 DH-SMT DN
WebAccess
System requirements
Microsoft Explorer 6.xx browser or later versions
Adobe SVG Viewer 3.xx or later versions
Intranet / Internet connection
It is strongly recommended to write down the information that may be
needed on a later occasion.
Installation address
IP addresses*
IP address (fixed)
Subnet mask
Default gateway
* All addresses must be written as digits
E-mail accounts
Name SMTP addresses*
* All addresses must be written as digits
Before you start
ECL name (menu location 1-4)
1 3
2 4
Menu option: Configuration / Installation address
Menu option: Configuration / IP addresses
Menu option: Configuration / E-mail accounts
Menu option: Configuration / Units
DH-SMT DN VI.KM.H1.02 © Danfoss 06/2005 3
WebAccess
Pulse interface 1
ECL menu location Menu label
1 2 3 4
Description Pulse factor Unit
/
/
/
/
Pulse interface 2
ECL menu location Menu label
1 2 3 4
Description Pulse factor Unit
/
/
/
/
Heat meters
ECL menu location Menu label
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
Menu option: Configuration / Units
Menu option: Configuration / Units / Additional modules / Add (Edit)
Menu option: Configuration / Units / Additional modules / Add (Edit)
Menu option: Configuration / Units / Additional modules / Add (Edit)
4 VI.KM.H1.02 © Danfoss 06/2005 DH-SMT DN
WebAccess
Pulse interface 3
ECL menu location Menu label
1 2 3 4
Description Pulse factor Unit
/
/
/
/
Pulse interface 4
ECL menu location Menu label
1 2 3 4
Description Pulse factor Unit
/
/
/
/
Menu option: Configuration / Units / Additional modules / Add (Edit)
Menu option: Configuration / Units / Additional modules / Add (Edit)
DH-SMT DN VI.KM.H1.02 © Danfoss 06/2005 5
WebAccess
Analog interface 1
ECL menu location Menu label
1 2 3 4
Description
Range
Unit
0 V 10 V
Analog interface 2
ECL menu location Menu label
1 2 3 4
Description
Range
Unit0 V 10 V
Menu option: Configuration / Units / Additional modules / Add (Edit)
Menu option: Configuration / Units / Additional modules / Add (Edit)
6 VI.KM.H1.02 © Danfoss 06/2005 DH-SMT DN
WebAccess
LON wiring
DH-SMT DN VI.KM.H1.02 © Danfoss 06/2005 7
WebAccess
Wiring to the ECL Comfort controller
Step 1
Mount the ECA 82 LON module
in the ECL Comfort controller by
dismounting cover plate B on the
back of the ECL Comfort by means of
a small slice cutter nipper.
Step 2
Mount the ECA 82 in the slides and
press it gently into the connector on
the ECL Comfort print board.
8 VI.KM.H1.02 © Danfoss 06/2005 DH-SMT DN
WebAccess
Step 3
Mount the new cover plate B, which
is delivered with the option card.
Pin connection ECA 82:
1: LON data 1. Left side pin of the
connector.
2: Middle pin of the connector. Do
not use!
3: LON data 2. Right side pin of the
connector.
LON data 1 and 3 can be reversed.
Pin connection WebAccess unit:
1: LON data 1. Left side pin of the
connector.
2: LON data 2. Right side pin of the
connector.
LON data 1 and 2 can be reversed.
Step 4
Mount the LON connectors in the
WebAccess unit and in the ECA 82
module.
LON termination
Check that the termination jumper is
mounted as ‘FT’.
WebAccess
(TP/FT-10)
ECA 82
2
1 3
DH-SMT DN VI.KM.H1.02 © Danfoss 06/2005 9
WebAccess
LAN / Ethernet wiring
10 VI.KM.H1.02 © Danfoss 06/2005 DH-SMT DN
WebAccess
Powering up
When powering up the ECL Comfort controller, a period of about 30 seconds
will elapse during which the database of the controller will be copied to
the ECA 82 module. During this period it is not possible to contact the ECA
82 module, neither from the ECL Comfort controller nor from the network.
The start-up period will occur in connection with reset / powering up of the
controller and ECA 82 module and also when the application is changed in
the ECL Comfort controller.
The WebAccess unit needs 2-3 min. to start up. During start-up, the status
LED has a constant light. The unit is ready when the status LED starts flashing.
Ethernet configuration
First of all, the contact to the WebAccess unit must be established. This is
achieved by means of a PC (Laptop / Notebook) and an xover Ethernet
cable.
Connect the Ethernet cable and configure your PC to the fixed IP addresses:
IP: 192.168.1.32
Subnet: 255.255.255.0
Gateway: No
Now the WebAccess unit can be contacted with the IP address 192.168.1.100
via the Microsoft Internet Explorer.
Remember to install the Adobe SVG Viewer before contacting the WebAccess
unit. It can be downloaded for free from www.adobe.com. If you fail to install
the Adobe SVG Viewer, you will not be able to see the application graphics.
Status LED
DH-SMT DN VI.KM.H1.02 © Danfoss 06/2005 11
WebAccess
Add the ECL Comfort applications to the WebAccess unit:
Select menu option: Configuration / Units
Add ECL
Click ‘Add. State the ECL name for this menu location. If you already
have set up alarm recipients, choose the one to be alerted in case of
communication failure. Click ‘Continue’.
Follow the instructions on the screen.
Edit ECL
Click ‘Edit. Edit the ECL name for this menu location. Choose alarm
recipient in case of communication failure. Click ‘save’.
Remove ECL
Click ‘Remove’ for the ECL you want to disconnect. Confirm the removal
of the selected ECL by clicking ‘Remove’ once again.
Configuration of ECL Comfort controllers
12 VI.KM.H1.02 © Danfoss 06/2005 DH-SMT DN
WebAccess
Configuration of modules
Select menu option: Configuration / Units / Additional modules
Add
Click ‘Add. State the module name and choose under which ECL menu
locations the module is to be shown. If you already have set up alarm
recipients, choose the one to be alerted in case of communication
failure. Click ‘Continue’.
Follow the instructions on the screen.
Edit
Click ‘Edit. Edit the module name for this menu location. Choose alarm
recipient in case of communication failure. Click ‘save’.
Remove
Click ‘Remove’ for the module you want to disconnect. Confirm the
removal of the selected module by clicking ‘Remove’ once again.
When a new ECL unit or additional module is added, you might be asked
to close your Internet browser and then restart it. This also applies if units
/ additional modules have been changed or deleted when you close the
dialog. This enables the Internet Explorer to show you the new / changed
units / additional modules correctly.
DH-SMT DN VI.KM.H1.02 © Danfoss 06/2005 13
WebAccess
Configuration of input channels
Heat meters:
No additional set-up is required.
WAH pulse interface:
Select the ECL menu location under which the pulse interface is shown.
Select the menu option: Modules / ‘Menu label.
Click ‘Add’ and confirm use of licence.
Click ‘Edit. State the name / description, units (kWh or m
3
) and pulse
factor. Also state the accumulated value of the meter (actual value
displayed on the meter) and the max. possible value of the meter.
WAH analog interface:
Select the ECL menu location under which the analog interface is shown.
Select the menu option: Modules / ‘Menu label.
Click ‘Add’ and confirm use of licence.
Click ‘Edit. State the name / description and units. Set the range of the
input device by stating the min. / max. value that equals 0 and 10 V.
14 VI.KM.H1.02 © Danfoss 06/2005 DH-SMT DN
WebAccess
Set the IP address, subnet mask and standard gateway of the WebAccess data
logger to comply with the relevant network. You can get these addresses
from your network administrator or from your Internet supplier.
When the IP address is changed, the WebAccess data logger restarts. After
a period of 2-5 min. the Internet explorer should be restarted, and the
WebAccess data logger can be found on the new IP address.
It is extremely important to remember your IP address. Without this
address, it will not be possible to access the data logger again.
IP configuration
DH-SMT DN VI.KM.H1.02 © Danfoss 06/2005 15
WebAccess
1. TP / FT-10 LON connection: Free topology / twisted pair
2. Power supply: 8-24 V a.c. or 12-30 V d.c.
3. RS 232 interface for PC connection or external GSM / analog modem
(only for 087B1189)
4. Ethernet connection
5. TP / FT-10 LON connection: Free topology / twisted pair
6. Wireless
Constant light: Fatal error “no net.
It is not possible to get connected to the network (typically the SIM
card is missing)
Slowly flashing light (½ Hz) : Connected to GSM “net found!
Fast flashing light (1 Hz): Connected to “dial up”
7. Status
Constant light: The data logger is starting up and and there is no
connection
Flashing light: The data logger is ready
8. 100 Mb
Flashing light: Data are being trasmitted via the Ethernet
9. Link
Constant light: The data logger is connected to the Ethernet
10. Power
Constant light: The data logger is connected to the mains
No light: The power is disconnected
11. Service (configuration of data logger)
Flashing light: The data logger is not configured
Light emitting diodes
16 VI.KM.H1.02 © Danfoss 06/2005 DH-SMT DN
WebAccess
WAH analog interface
DH-SMT DN VI.KM.H1.02 © Danfoss 06/2005 17
WebAccess
WAH pulse interface
18 VI.KM.H1.02 © Danfoss 06/2005 DH-SMT DN
WebAccess
Screen examples
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Danfoss WebAccess for ECL Comfort 200 / 300 Operating instructions

Type
Operating instructions

Danfoss WebAccess for ECL Comfort 200 / 300 enables remote access to your heating system via the internet. With this device, you can monitor and control your heating system from anywhere with an internet connection. The WebAccess data logger is easy to install and set up, and it comes with a user-friendly interface that makes it easy to navigate and use.

With Danfoss WebAccess for ECL Comfort 200 / 300, you can:

  • Monitor your heating system's performance in real time
  • Adjust your heating settings remotely
  • Receive alerts if there are any problems with your heating system
  • Set up multiple users with different access levels