1
DA2159i
3.25"
(8.3 cm)
3" [min]
(7.6 cm)
PENCIL
MARK
EDGE OF
CEILING
HANGER
BRA
CKET
DESIRED HEIGHT
OF CABINET
(MUST BE
AT LEAST
3" FROM CEILING)
SHIM
EDGE OF
FLOOR
1.63"
(4.1 cm)
003-1941-00 Rev.A
12” 15” 18” 24” 30” Upper Storage Unit Installation
Applies to Models:
OUC (012, 015, 018)
OUC (024, 030)
Special Tools:
Level
Stud Finder
Step 1: Measure up 71 1/2”
(181.6 cm) from
highest point on floor.
Step 2: Measure down 1.63” (4.1cm) from
71 1/2” (181.6 cm) mark. Using a
level, mark a line along the entire
length of the storage unit.
Step 3: Align bottom of bracket
with mark. Secure with
appropriate hardware
using shims if necessary.
Note
If necessary to form bracket to
wall, use double-sided tape
and shims behind bracket.
Note
Midmark recommends
that bottom of cabinet
should be 18” (45.7 cm)
above counter top.
OUC012 (12” Upper Storage Unit)
OUC015 (15” Upper Storage Unit)
OUC018 (18” Upper Storage Unit)
OUC024 (24” Upper Storage Unit)
OUC030 (30” Upper Storage Unit)