Legrand Optimo Installation guide

Type
Installation guide

Legrand Optimo connectors offer a versatile solution for your fiber optic needs. Compatible with LC, SC, and ST connectors, these connectors provide reliable performance for a range of applications. Designed for use with 900 µm buffered fiber or loose tube with a breakout kit, they ensure a secure and efficient connection. With easy installation and precise cleave inspection, Optimo connectors are the ideal choice for installers and technicians seeking top-quality fiber optic connectivity.

Legrand Optimo connectors offer a versatile solution for your fiber optic needs. Compatible with LC, SC, and ST connectors, these connectors provide reliable performance for a range of applications. Designed for use with 900 µm buffered fiber or loose tube with a breakout kit, they ensure a secure and efficient connection. With easy installation and precise cleave inspection, Optimo connectors are the ideal choice for installers and technicians seeking top-quality fiber optic connectivity.

OR-71601671
OptiMo
®
LC, SC and ST Compatible Connectors
Installation Instructions
OptiMo Connector Installation Instructions Page i
OptiMo
®
Connector
Installation Instructions
Information subject to change without notice. Ortronics reserves
the right to make changes in product design or components as
progress in engineering or manufacturing may warrant.
OptiMo implies the OptiMo Multimode (50 µm & 62.5 µm) and Singlemode connectors
INST REV ECN DWN BY DATE CHK BY DATE APP BY DATE
OptiMo
®
is a registered trademark of Ortronics/Legrand
OptiMo Connector Installation Instructions Page iii
Table of contents
About this guide iv
Safety precautions v
Installation on 900 µm buffered fiber or loose tube with breakout kit 1
Installation on jacketed fiber 33
Cleaning procedures 64
Fiber Preparation Guide ANNEX
OR-71601671 Page iv
About this guide
This guide contains assembly procedures for the OptiMo
®
Connector.
Before starting an installation, check to make sure that you have the required tools and materials outlined at the
start of the procedure.
Review each procedure to familiarize yourself with the graphic symbols and the actions required.
OptiMo Connector Installation Instructions Page v
CAUTION:
When installed on a live system, invisible laser radiation may be present.
Do not stare into connector endface or view directly with optical instruments.
Wear safety glasses when working with optical fiber.
Dispose of all scrap fiber in the waste bottle to avoid getting fiber slivers.
Safety precautions
OR-71601671 Page vi
LC
connector body
dust cap
dust cap
Accessories
crimp sleeves
900 µm strain relief boot
disposable tool
Release wire
strain relief boots
2.0 mm
2.0 mm
3.0 mm
22 mmmm
33 mmmm
3.0 mm
connector body
dust cap
dust cap
Cord adapter
crimp sleeves
strain relief boots
release wire
disposable tool
3.0 mm
jacketed
jacketed
900 µm
2.4 mm
connector body
front dust cap
rear dust cap
crimp sleeves
rear housing
strain relief boots
3.0 mm
2.4 mm
900 µm
SC
ST
Connector components
OptiMo Connector Installation Instructions Page vii
Connector installation tools
tweezers
alcohol wipes
microscope
crimping tool
ink marker
fiber cleaver
universal stripper
scissors
installation manual
universal installation tool
tool clamp
fiber waste bottle
OR-71601671
OptiMo
®
LC, SC and ST Compatible Connectors
Installation Instructions
table top base
multihead adapter
Page 1OptiMo Connector Installation Instructions
connector body
900 µm strain relief boot
LC
SC ST
connector body
900 µm strain relief boot
connector body with dust caps
rear housing
900 µm strain relief boot
1
Open the bag and select the parts required for installation on 900 µm buffered fiber.
(Connector body and 900 µm strain relief boot.)
Installation on 900 µm buffered fiber or loose tube with breakout kit
Installation on 900 µm buffered fiber or loose tube with breakout kit
OR-71601671 Page 2
2
a Install the installation tool on the C clamp as shown, then clamp to the table. The table top base can be
used as an alternative.
Installation on 900 µm buffered fiber or loose tube with breakout kit
Page 3OptiMo Connector Installation Instructions
2
b Install the multihead adapter on the tool in the appropriate position as illustrated below.
LC position SC position ST position
Installation on 900 µm buffered fiber or loose tube with breakout kit
OR-71601671 Page 4
3
Load the connector body into the installation tool, with the release wire up.
Leave dust cap on. Leave dust cap on.
LC
SC ST
By pushing the housing into the
receptacle and turning 1/4 turn
clockwise, locking it in place.
Leave dust caps on.
Release wire
Installation on 900 µm buffered fiber
Page 5OptiMo Connector Installation Instructions
4
Slide the boot down the fiber, narrow
end first, until it is out of the way.
Slide the boot down the fiber, narrow
end first, until it is out of the way.
Slide the 900 µm strain relief boot onto
the rear housing until it locks in place.
(Holding the boot on it’s smaller end will
ease insertion.) Slide the rear housing
with boot down the fiber, narrow end
first, until it is out of the way.
LC
SC ST
Page 6
5
Strip approximately 40 mm of the 900 µm buffered fiber as shown below. Be sure to strip fiber in small
(5 mm) sections to avoid breaking it. Buffer end should be clean and square.
Fiber waste
Fig. 1 Fig. 2 Fig. 3
Step 1. (Fig. 1) Insert fiber into Step 2. (Fig. 2) Close the tool Step 3. (Fig. 3) Draw the tool along the fiber
250 µm "V" opening of the tool. squarely around the fiber. using thumb pressure while keeping the tool
perpendicular to the fiber.
900 µm "V" opening
250 µm "V" opening
Installation: stripping 900 µm tight buffered fiber (if using loose tube with breakout kit, skip to step 11)
*
If unfamiliar with stripping optical fiber, it is advised to practice using a spare piece of fiber.
*
Make sure the fiber optic stripper tool you are using is in proper operating condition before attempting this step.
Use of a tool that is not in proper operating condition could cause the fiber to break.
OR-71601671
Installation: stripping 900 µm tight buffered fiber (if using loose tube with breakout kit, skip to step 11)
Page 7
6
Strip approximately 40 mm of the 900 µm buffered fiber. Be sure to strip fiber in small (5 mm) sections to
avoid breaking it. Buffer end should be clean and square. After stripping, measure and mark the buffer
from its end as illustrated below.
*
If unfamiliar with stripping optical fiber, it is advised to practice using a spare piece of fiber.
15 mm
Fiber waste
11 mm
9 mm
LC
SC
ST
OptiMo Connector Installation Instructions
Installation on 900 µm buffered fiber
Page 8
7
Carefully clean the bare fiber with a folded alcohol wipe or alcohol soaked lint-free paper. Use two or
three passes. Avoid touching the bare fiber, or laying it down on the table, after it has been cleaned.
OR-71601671
Page 9
8
a Cleave the fiber 7 mm from the end of the buffer. Be sure to read and understand the procedure
included with your cleaver that is provided with your Ortronics
®
Field Installation Kit prior to
attempting this step. (The procedure can be downloaded from the Ortronics web site at
http://www.legrand.us/ortronics/technicalresources/instruction%20manuals.aspx)
Fiber waste
Pre-Set Cleaver Installation on 900 µm tight buffered fiber (if using an adjustable cleaver, skip to step 8b)
*
If unfamiliar with cleaving, it is advised to practice using a spare piece of fiber. Generally, a light touch is all that is
required to score the fiber. The fiber buffer must rest against the stop.
*
Alternative cleavers which produce a 7 mm bare fiber length may be used.
+0.5
-0.0
OptiMo Connector Installation Instructions
Page 10
8
b Cleave the fiber 7 mm from the end of the buffer. Be sure to read and understand the procedure
included with your cleaver that is provided with your Ortronics
®
Field Installation Kit prior to
attempting this step. (The procedure can be downloaded from the Ortronics web site at
http://www.legrand.us/ortronics/technicalresources/instruction%20manuals.aspx)
Fiber waste
Adjustable Cleaver Installation on 900 µm tight buffered fiber
*
If unfamiliar with cleaving, it is advised to practice using a spare piece of fiber. Generally, a light touch is all that is
required to score the fiber. The fiber buffer must be set to produce a 7 mm bare fiber length.
*
Alternative cleavers which produce a 7 mm bare fiber length may be used.
+0.5
-0.0
+0.5
-0.0
OR-71601671
Installation on 900 µm buffered fiber
Page 11
9
Cleave the fiber 7 mm from the end of the buffer. Be sure to read and understand the operating
instructions included with the cleaver. Using tweezers, discard waste fiber into the proper waste container.
*
If unfamiliar with cleaving, it is advised to practice using a spare piece of fiber. Generally, a light touch is all that is
required to score the fiber. The fiber buffer must rest against the stop.
*
Alternative cleavers which produce a 7 mm bare fiber length may be used.
Fiber waste
+0.5
-0.0
OptiMo Connector Installation Instructions
Installation on 900 µm buffered fiber
Page 12
10
Use the microscope to check the quality of the cleave. Pointing the microscope at a white surface will
provide a brighter image.
2
2
Make sure fiber position is as illustrated.
Turn microscope over and place fiber on stage.
1
1
OR-71601671
*
Note: If the Ortronics
®
Precision Cleave Tool (OR-60300189) is used, cleave inspection with a microscope is not required.
Installation on 900 µm buffered fiber
Page 13
Unacceptable cleaves
Acceptable cleave
Close stage and check fiber. It is recommended to rotate the fiber 90
0
-180
0
to verify from different angles.
3
3
*
Note: Batteries are not required.
If the cleave is unacceptable, then the fiber must be re-prepared starting from step 5. If fiber or fiber endface
appear dirty clean it as in step 6.
Once this step is successfully completed, proceed to step 11
OptiMo Connector Installation Instructions
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76

Legrand Optimo Installation guide

Type
Installation guide

Legrand Optimo connectors offer a versatile solution for your fiber optic needs. Compatible with LC, SC, and ST connectors, these connectors provide reliable performance for a range of applications. Designed for use with 900 µm buffered fiber or loose tube with a breakout kit, they ensure a secure and efficient connection. With easy installation and precise cleave inspection, Optimo connectors are the ideal choice for installers and technicians seeking top-quality fiber optic connectivity.

Ask a question and I''ll find the answer in the document